SFCC 1 Connector AB/4E to FDIMU Connector AA/3A
SFCC 1 Connector AB/4F to FDIMU Connector AA/3B
SFCC 2 Connector AB/4E to FDIMU Connector AB/3A
SFCC 2 Connector AB/4F to FDIMU Connector AB/3B
(3) If the fault continues:
- replace the FDIMU (10TV) (Ref. AMM TASK 31-36-34-000-002) and (Ref. AMM TASK 31-36-34-400-002).
B. Do the test given in para. 3.
FDIMU receives no data from the SDAC 1 (1WV1) or SDAC 2 (1WV2)
1. Possible Causes
_______________
- SDAC-1 (1WV1)
- SDAC-2 (1WV2)
- DMU/FDIU (FDIMU) (10TV)
- wiring
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
AMM 31-36-00-740-012 Test of the FDIMU (10TV)
AMM 31-36-34-000-002 Removal of the FDIU/DMU (FDIMU) (10TV)
AMM 31-36-34-400-002 Installation of the FDIU/DMU (FDIMU) (10TV)
AMM 31-50-00-710-001 Ground Scanning of the Central Warning System
ASM 31-37/01
3. Fault Confirmation
__________________
A. Do the FDIMU (10TV) fault monitoring test (AIDS-part) (Ref. AMM TASK 31-36-00-740-012).
NOTE : Make sure that the circuit breakers 5TV, 6WV, 7WV, 8WV, 9WV on the
____ panel 121VU and 2WV, 3WV, 5WV, 10WV, 12WV on the panel 49VU are closed during the test.
4. Fault Isolation
_______________
A. If the test gives the maintenance message:
- SDAC1 (1WV1) / FDIMU (10TV) or
- SDAC2 (1WV2) / FDIMU (10TV)
(1) Do the ground scanning of the central warning system (Ref. AMM TASK 31-50-00-710-001).
(a) If the test gives a different maintenance message, you can find the related trouble shooting procedure in the applicable Page Block 101.
(2) If the fault continues:
- do a check and if necessary repair the wiring between the SDAC-1 (1WV1) or SDAC-2 (1WV2) and the DMU/FDIU (FDIMU) (10TV) (Ref. ASM 31-37/01):
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1R EFF : 106-149, 211-299, 301-399, 401-499, ∞∞31-36-00∞∞∞∞∞∞∞∞∞∞Page A202
Aug 01/05 CES
SDAC 1 Connector AB/8J to FDIMU Connector AA/6G
SDAC 1 Connector AB/8K to FDIMU Connector AA/6H
or
SDAC 2 Connector AB/8J to FDIMU Connector AB/6G
SDAC 2 Connector AB/8K to FDIMU Connector AB/6H
(3) If the fault continues:
- replace the FDIMU (10TV) (Ref. AMM TASK 31-36-34-000-002) and (Ref. AMM TASK 31-36-34-400-002).
B. Do the test given in para. 3.
FDIMU receives no data from the ACARS-MU (1RB) or ATSU (1TX1)
1. Possible Causes
_______________
- ATSU (1TX1)
- DMU/FDIU (FDIMU) (10TV)
- wiring
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------
AMM 31-36-00-740-012 Test of the FDIMU (10TV)
AMM 31-36-34-000-002 Removal of the FDIU/DMU (FDIMU) (10TV)
AMM 31-36-34-400-002 Installation of the FDIU/DMU (FDIMU) (10TV)
AMM 46-21-00-710-001 Operational Test of the ATSU
ASM 31-36/05
3. Fault Confirmation
__________________
A. Do the FDIMU (10TV) fault monitoring test (AIDS-part) (Ref. AMM TASK 31-36-00-740-012).
NOTE : Make sure that the circuit breakers 5TV, 5TX1 on the panel 121VU
____
are closed during the test.
4. Fault Isolation
_______________
A. If the test gives the maintenance message:
- ATSU (1TX1) / FDIMU (10TV)
(1) Do the operational test of the ATSU (Ref. AMM TASK 46-21-00-710-001).
(a) If the test gives a different maintenance message, you can find the related trouble shooting procedure in the applicable Page Block 101.
(2) If the fault continues:
- do a check and repair the wiring from the ATSU (1TX1) to the DMU/FDIU (FDIMU) (10TV) (Ref. ASM 31-36/05):