3. Fault Confirmation
__________________
A. Do the test of the FDIMU (10TV) (Ref. AMM TASK 31-36-00-740-012).
4. Fault Isolation
_______________
A. If the test gives the maintenance message as listed below do the related trouble shooting procedure:
- "DFDR" (Ref. TASK 31-33-00-810-801)
- "QAR" (Ref. TASK 31-33-00-810-803)
- "QAR MEDIA" (Ref. TASK 31-33-00-810-804)
- "ACCELEROMETER" (Ref. TASK 31-33-00-810-805)
- "DFDR PLAYBACK" (Ref. TASK 31-33-00-810-806)
- "NO AC IDENT" (Ref. TASK 31-33-00-810-807)
- "PCMCIA MEDIA" (Ref. TASK 31-36-00-810-900)
- "DAR" (Ref. TASK 31-36-00-810-802)
- "DAR MEDIA" (Ref. TASK 31-36-00-810-803)
- "BATTERY" (Ref. TASK 31-36-00-810-899)
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1R EFF : 106-149, 211-299, 301-399, 401-499, ∞∞31-36-00∞∞∞∞∞∞∞∞∞∞Page 270
Aug 01/05 CES
(1) If the test gives a message related to a FDIMU internal failure replace the DMU/FDIU (FDIMU) (10TV) (Ref. AMM TASK 31-36-34-000-002) and (Ref. AMM TASK 31-36-34-400-002).
(2) If the test gives a message "NO RESPONSE" (FDIU part and DMU part):
- make sure that the CB 5TV is closed
- do a check for 115 VAC at the FDIMU (10TV) connectors AC/1 and AC/7 (Ref. ASM 31-36/01).
(a) If there is 115 VAC:
- replace the DMU/FDIU (FDIMU) (10TV) (Ref. AMM TASK 31-36-34-000-002) and (Ref. AMM TASK 31-36-34-400-002).
(b) If there is no 115 VAC:
- do a check and repair the wiring between the DMU/FDIU (FDIMU) (10TV) and CB 5TV and Ground points (Ref. ASM 31-36/01):
1_ from FDIMU AC/1 to CB 5TV/2
2_ from FDIMU AC/7 to ground
3_ from FDIMU AA/15J to ground
4_ from FDIMU AA/15K to ground
5_ from FDIMU AB/15J to ground
6_ from FDIMU AB/15K to ground.
B. Do the test given in para. 3.
TASK 31-36-00-810-899
FDIMU Battery (10TV)
1. Possible Causes_______________
R R - DMU/FDIU (FDIMU) (10TV)
2. Job Set-up Information______________________
A. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
R R AMM AMM AMM 31-36-00-740-012 31-36-34-000-002 31-36-34-400-002 Test of the FDIMU (10TV) Removal of the FDIU/DMU (FDIMU) (10TV) Installation of the FDIU/DMU (FDIMU) (10TV)
3. Fault Confirmation__________________
A. Do the test of the FDIMU (10TV) (Ref. AMM TASK 31-36-00-740-012).
4. Fault Isolation_______________
R R R R A. If the FDIMU (10TV) test gives the maintenance message FDIMU BATTERY (10TV) only: - replace the DMU/FDIU (FDIMU) (10TV) (Ref. AMM TASK 31-36-34-000-002) (Ref. AMM TASK 31-36-34-400-002).
B. Do the test given in para. 3.
FDIMU PCMCIA MEDIA (10TV)
1. Possible Causes
_______________
- PCMCIA-Card
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
AMM 31-36-00-000-001 Removal of the Personal Computer Memory Card (PCMCIA) AMM 31-36-00-400-001 Installation of the Personal Computer Memory Card (PCMCIA) AMM 31-36-00-740-012 Test of the FDIMU (10TV)
3. Fault Confirmation
__________________
A. Do the test of the FDIMU (10TV) (Ref. AMM TASK 31-36-00-740-012).
4. Fault Isolation
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320 Trouble Shooting Manual 排故手册 指示和记录系统 1(100)