「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞31-32-00∞∞∞∞∞∞∞∞∞∞Page A200
May 01/05R
CES Loss of the Bus Output from the DMC 3 to the CFDIU
1. Possible Causes
_______________
- CFDIU (1TW)
- DMC-3 (1WT3)
- wiring from the CFDIU (1TW) to the DMC 3 (1WT3)
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
AMM 31-32-00-869-002 Procedure for Class 3 Faults Reading
AMM 31-32-34-000-001 Removal of the CFDIU (1TW)
AMM 31-32-34-400-001 Installation of the CFDIU (1TW)
AMM 31-63-34-000-001 Removal of the DMC (1WT1,1WT2,1WT3)
AMM 31-63-34-400-001 Installation of the DMC (1WT1,1WT2,1WT3)
ASM 31-32/05
3. Fault Confirmation
__________________
A. Make sure that this(these) circuit breaker(s) is(are) closed:
-------------------------------------------------------------------------------PANEL DESIGNATION IDENT. LOCATION -------------------------------------------------------------------------------49VU EIS/DMC3/SWTG 21WT3 E07 121VU EIS/DMC3/SPLY 10WT3 Q09
B. Test On the CFDS MENU page, get access to the AVIONICS STATUS page (Ref. AMM TASK 31-32-00-869-002).
4. Fault Isolation
_______________
A. If the test gives the maintenance message NO DMC 3 DATA:
- replace the CFDIU (1TW) (Ref. AMM TASK 31-32-34-000-001) and (Ref. AMM TASK 31-32-34-400-001).
(1) If the fault continues:
- replace the DMC-3 (1WT3) (Ref. AMM TASK 31-63-34-000-001) and (Ref. AMM TASK 31-63-34-400-001).
(2) If the fault continues:
- do a check and repair the wiring from the CFDIU (1TW) to the DMC 3 (1WT3) from pins AA/2H, 2J to pins AB/1C, 1D (Ref. ASM 31-32/05).
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞31-32-00∞∞∞∞∞∞∞∞∞∞Page A201
May 01/05R CES
B. Do the test given in Para. 3.B.
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞31-32-00∞∞∞∞∞∞∞∞∞∞Page A202
May 01/05R
CES Loss of the Bus Output from the Printer to the CFDIU
1. Possible Causes
_______________
- CFDIU (1TW)
- wiring
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
AMM 31-32-00-740-003 Ground Scanning of the CFDIU
AMM 31-32-34-000-001 Removal of the CFDIU (1TW)
AMM 31-32-34-400-001 Installation of the CFDIU (1TW)
ASM 31-32/07
3. Fault Confirmation
__________________
A. Make sure that this(these) circuit breaker(s) is(are) closed:
-------------------------------------------------------------------------------PANEL DESIGNATION IDENT. LOCATION -------------------------------------------------------------------------------
121VU PTR/SPLY 6TW J21
B. Test Do the ground scanning of the CFDIU (Ref. AMM TASK 31-32-00-740-003).
4. Fault Isolation
_______________
A. If the test gives the maintenance message NO PRINTER DATA:
- replace the CFDIU (1TW) (Ref. AMM TASK 31-32-34-000-001) and (Ref. AMM TASK 31-32-34-400-001).
(1) If the fault continues:
- do a check and repair the wiring from the CFDIU (1TW) pins AA/8H, 8J to the first terminal block (Ref. ASM 31-32/07).
B. Do the test given in Para. 3.B.
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞31-32-00∞∞∞∞∞∞∞∞∞∞Page A203
May 01/05R CES
Failure of the CFDIU
1. Possible Causes
_______________
- CFDIU (1TW)
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320 Trouble Shooting Manual 排故手册 指示和记录系统 1(32)