 2. Job Set-up Information
______________________
 A. Referenced Information
 -------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
AMM 31-51-00-610-001 Load OEB REMINDER information into FWCs using MCDUs. AMM 31-51-00-610-002 Delete OEB REMINDER information from FWCs using MCDUs. AMM 31-53-34-000-001 Removal of the Flight Warning Computer (FWC) (1WW1,1WW2) AMM 31-53-34-400-001 Installation of the Flight Warning Computer (FWC) (1WW1,1WW2)
 3. Fault Confirmation
__________________
 A. Do a new OEB DATABASE creation (Ref. AMM TASK 31-51-00-610-001) or
 deletion (Ref. AMM TASK 31-51-00-610-002).

 4. Fault Isolation
_______________
 A. If the UPDATE FAILED message comes into view on the ECAM1/OEB DATABASE UPDATE page:
 - replace the FWC-1 (1WW1) (Ref. AMM TASK 31-53-34-000-001) (Ref. AMM TASK 31-53-34-400-001).

 


 Creation or Deletion in the ECAM2/OEB DATABASE not Possible
 1. Possible Causes
_______________
 - FWC-2 (1WW2)
 2. Job Set-up Information
______________________
 A. Referenced Information
 -------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
AMM 31-51-00-610-001 Load OEB REMINDER information into FWCs using MCDUs. AMM 31-51-00-610-002 Delete OEB REMINDER information from FWCs using MCDUs. AMM 31-53-34-000-001 Removal of the Flight Warning Computer (FWC) (1WW1,1WW2) AMM 31-53-34-400-001 Installation of the Flight Warning Computer (FWC) (1WW1,1WW2)
 3. Fault Confirmation
__________________
 A. Do a new OEB DATABASE creation (Ref. AMM TASK 31-51-00-610-001) or
 deletion (Ref. AMM TASK 31-51-00-610-002).

 4. Fault Isolation
_______________
 A. If the UPDATE FAILED message comes into view on the ECAM2/OEB DATABASE UPDATE page:
 - replace the FWC-2 (1WW2) (Ref. AMM TASK 31-53-34-000-001) (Ref. AMM TASK 31-53-34-400-001).

 

 Crossloading from FWC2 OEB DATABASE not Possible
 1. Possible Causes_______________
 - FWC-2 (1WW2)

 - wiring of the data bus between the FWC2 output bus and the FWC1 input bus


 2. Job Set-up Information______________________
 A. Referenced Information
 -------------------------------------------------------------------------------
REFERENCE  DESIGNATION
 -------------------------------------------------------------------------------
AMM 31-51-00-610-003  Crossload OEB REMINDER information into FWCs using MCDUs.
 AMM 31-53-34-000-001  Removal of the Flight Warning Computer (FWC) (1WW1,1WW2)
 AMM 31-53-34-400-001  Installation of the Flight Warning Computer (FWC) (1WW1,1WW2)
 AWM 31-52-03
 3. Fault Confirmation__________________
 A. Do a new crossloading from the FWC2 (Ref. AMM TASK 31-51-00-610-003).
 4. Fault Isolation_______________
 A. If the UNABLE TO CROSSLOAD message comes into view on the ECAM1/OEB
 DATABASE UPDATE page:

 - replace the FWC-2 (1WW2) (Ref. AMM TASK 31-53-34-000-001) (Ref. AMM TASK 31-53-34-400-001).
 (1) If the fault continues:
 - do a check and repair the wiring of the data bus between the FWC2 output bus and the FWC1 input bus (Ref. AWM 31-52-03).

 

 Crossloading from FWC1 OEB DATABASE not Possible
 1. Possible Causes_______________
 - FWC-1 (1WW1)

 - wiring of the data bus between the FWC1 output bus and the FWC2 input bus


 2. Job Set-up Information______________________
 A. Referenced Information
 -------------------------------------------------------------------------------
REFERENCE  DESIGNATION
 -------------------------------------------------------------------------------
AMM 31-51-00-610-003  Crossload OEB REMINDER information into FWCs using MCDUs.
 AMM 31-53-34-000-001  Removal of the Flight Warning Computer (FWC) (1WW1,1WW2)
 AMM 31-53-34-400-001  Installation of the Flight Warning Computer (FWC) (1WW1,1WW2)
 ASM 31-52/03
 3. Fault Confirmation__________________
 A. Do a new crossloading from the FWC1 (Ref. AMM TASK 31-51-00-610-003).
 4. Fault Isolation_______________
 A. If the UNABLE TO CROSSLOAD message comes into view on the ECAM2/OEB
 DATABASE UPDATE page:

 - replace the FWC-1 (1WW1) (Ref. AMM TASK 31-53-34-000-001) (Ref. AMM TASK 31-53-34-400-001).
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320 Trouble Shooting Manual 排故手册 指示和记录系统 1(120)