3. Fault Confirmation
__________________
A. Make sure that this(these) circuit breaker(s) is(are) closed:
-------------------------------------------------------------------------------PANEL DESIGNATION IDENT. LOCATION -------------------------------------------------------------------------------49VU CLOCK/NORM/SPLY 6FS F11
B. Test Do the operational test of the AFS (Ref. AMM TASK 22-96-00-710-001) and read the result for the FMGC 1 and the FMGC 2.
4. Fault Isolation
_______________
A. If the test gives the maintenance message AFS : CLOCK:
- replace the FMGC-1 (1CA1), (Ref. AMM TASK 22-83-34-000-001) and (Ref. AMM TASK 22-83-34-400-001).
(1) If the fault continues:
- replace the FMGC-2 (1CA2).
(a) If the fault continues:
- do a check and repair the wiring from the FMGC 1 (1CA1) pins AA/13F, 13G to the first terminal block , (Ref. ASM 31-21/01).
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞31-21-00∞∞∞∞∞∞∞∞∞∞Page 205
Feb 01/00R CES
1_ If the fault continues:
- do a check and repair the wiring from the FMGC 2 (1CA2) pins
AA/13F, 13G to the first terminal block , (Ref. ASM 31-
21/01).
B. Do the test given in Para. 3.B.
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞31-21-00∞∞∞∞∞∞∞∞∞∞Page 206
Feb 01/00R
CES Loss of the Bus Output from the Clock Detected by the CFDIU
1. Possible Causes
_______________
- CLOCK (2FS)
- CFDIU (1TW)
- MMR-1 (40RT1)
- wiring
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION
-------------------------------------------------------------------------------
AMM 31-21-21-000-001 Removal of the Clock (2FS)
AMM 31-21-21-400-001 Installation of the Clock (2FS)
AMM 31-32-00-740-003 Ground Scanning of the CFDIU
AMM 31-32-34-000-001 Removal of the CFDIU (1TW)
AMM 31-32-34-400-001 Installation of the CFDIU (1TW)
AMM 34-36-31-000-002 Removal of the Multi Mode Receiver (40RT1, 40RT2)
AMM 34-36-31-400-002 Installation of the Multi Mode Receiver (40RT1,
40RT2)
ASM 31-21/01
3. Fault Confirmation
__________________
A. Make sure that this(these) circuit breaker(s) is(are) closed:
-------------------------------------------------------------------------------PANEL DESIGNATION IDENT. LOCATION -------------------------------------------------------------------------------49VU CLOCK/NORM/SPLY 6FS F11
B. Do the ground scanning of the CFDIU (Ref. AMM TASK 31-32-00-740-003).
4. Fault Isolation
_______________
R **ON A/C 001-049, 051-099, 101-105,
A. If the test gives the maintenance message:
CLOCK
- replace the CLOCK (2FS), (Ref. AMM TASK 31-21-21-000-001) and (Ref. AMM TASK 31-21-21-400-001).
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞31-21-00∞∞∞∞∞∞∞∞∞∞Page 207
May 01/05 CES (1) If the fault continues:
- replace the CFDIU (1TW), (Ref. AMM TASK 31-32-34-000-001) and (Ref. AMM TASK 31-32-34-400-001).
(a) If the fault continues:
- do a check and repair the wiring from the clock (2FS) connector A/W, X to the CFDIU (1TW) connector AA/9H, 9J (Ref. ASM 31-21/01).
R **ON A/C 106-149, 151-199, 201-299, 301-399, 401-499,
A. If the test gives the maintenance message:
CLOCK
- replace the CLOCK (2FS), (Ref. AMM TASK 31-21-21-000-001) and (Ref. AMM TASK 31-21-21-400-001).
(1) If the fault continues:
- replace the CFDIU (1TW), (Ref. AMM TASK 31-32-34-000-001) and (Ref. AMM TASK 31-32-34-400-001).
(2) If the fault continues:
- replace the MMR-1 (40RT1) (Ref. AMM TASK 34-36-31-000-002) and (Ref. AMM TASK 34-36-31-400-002).
(3) If the fault continues
- do a check and repair the wiring (Ref. ASM 31-21/01):
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320 Trouble Shooting Manual 排故手册 指示和记录系统 1(2)