3. Fault Confirmation
__________________
A. Do the DMU (1TV) fault monitoring test (Ref. AMM TASK 31-36-00-710-001). NOTE : Make sure that the circuit breakers 1TV, 2WZ, 3WZ on the panel
____
121VU are closed during the test.
4. Fault Isolation
_______________ R **ON A/C 001-049, 051-099, 101-105, 151-158, 201-209,
A. If the test gives the maintenance message:
- NO GPWS DATA
(1) Do the operational test of the Ground Proximity Warning System (Ref. AMM TASK 34-48-00-710-001).
(a) If the test gives a different maintenance message, you can find the related trouble shooting procedure in the applicable Page Block 101.
(2) If the fault continues:
- do a check and repair the wiring from the GPWC (1WZ) to the DMU (1TV) (Ref. ASM 31-37/01):
GPWC Connector AB/1C to DMU Connector AA/5C
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1R EFF : 001-049, 051-099, 101-105, 151-199, ∞∞31-36-00∞∞∞∞∞∞∞∞∞∞Page 231
201-210, May 01/05 CES (3) If the fault continues:
- replace the DMU (1TV) (Ref. AMM TASK 31-36-34-000-001) and (Ref. AMM TASK 31-36-34-400-001).
**ON A/C 159-199, 210-210,
A. If the test gives the maintenance message:
- GPWS (1WZ)/DMU (1TV).
(1) Do the operational test of the Ground Proximity Warning System (Ref. AMM TASK 34-48-00-710-001).
(a) If the test gives a different maintenance message, you can find the related trouble shooting procedure in the applicable Page Block 101.
(2) If the fault continues:
- do a check and repair the wiring from the GPWC (1WZ) to the DMU (1TV) (Ref. ASM 31-37/01):
GPWC Connector AB/1C to DMU Connector AA/5C GPWC Connector AB/1D to DMU Connector AA/5D
(3) If the fault continues:
- replace the DMU (1TV) (Ref. AMM TASK 31-36-34-000-001) and (Ref. AMM TASK 31-36-34-400-001).
R **ON A/C 001-049, 051-099, 101-105, 151-199, 201-210,
B. Do the test given in para. 3.
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1R EFF : 001-049, 051-099, 101-105, 151-199, ∞∞31-36-00∞∞∞∞∞∞∞∞∞∞Page 232
201-210, May 01/05 CES
DMU receives no data from the CFDS
1. Possible Causes
_______________
- CFDIU (1TW)
- DMU (1TV)
- wiring
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------
AMM 31-32-00-740-002 BITE Test of the Centralized Fault Display Interface
Unit (CFDIU) AMM 31-36-00-710-001 Test of the DMU (1TV) AMM 31-36-34-000-001 Removal of the Data Management Unit (DMU) (1TV) AMM 31-36-34-400-001 Installation of the Data Management Unit (DMU) (1TV) ASM 31-36/01
3. Fault Confirmation
__________________
A. Do the DMU (1TV) fault monitoring test (Ref. AMM TASK 31-36-00-710-001). NOTE : Make sure that the circuit breakers 1TV, 2TW, 8TW on the panel
____
121VU are closed during the test.
_______________
4. Fault Isolation
R **ON A/C 001-049, 051-099, 101-105, 151-158, 201-209,
A. If the test gives the maintenance message:
- NO CDFS DATA, or
- CFDS COMMUNIC FAIL
(1) Do the BITE Test of the Central Fault Display Interface System (CFDIU) (Ref. AMM TASK 31-32-00-740-002).
(a) If the test gives a different maintenance message, you can find the related trouble shooting procedure in the applicable Page Block 101.
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1R EFF : 001-049, 051-099, 101-105, 151-199, ∞∞31-36-00∞∞∞∞∞∞∞∞∞∞Page 233
201-210, May 01/05 CES (2) If the fault continues:
- do a check and repair the wiring from the CFDIU (1TW) to the DMU (1TV) (Ref. ASM 31-36/01):
CFDIU Connector AA/2B to DMU Connector AB/5C CFDIU Connector AA/2C to DMU Connector AB/5D CFDIU Connector AB/3F to DMU Connector AA/11E CFDIU Connector AB/3G to DMU Connector AA/11F