- replace the CFDIU (1TW), (Ref. AMM TASK 31-32-34-000-001) and (Ref. AMM TASK 31-32-34-400-001).
(1) If the fault continues:
- replace the CONTROLLER-VACUUM SYSTEM (31MG), (Ref. AMM TASK 38-31-34-000-001) and (Ref. AMM TASK 38-31-34-400-001).
(a) If the fault continues:
- do a check and repair the wiring from the CFDIU (1TW) to the vacuum system controller (31MG) from pins AB/4F, 4G to pins AB/3C, 4C , (Ref. ASM 31-32/03).
B. Do the test given in Para. 3.
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1R EFF : 001-049, 051-099, 101-105, 151-199, ∞∞31-32-00∞∞∞∞∞∞∞∞∞∞Page 255
201-299, May 01/05 CESR **ON A/C ALL
TASK 31-32-00-810-849
Loss of the Bus Output from the ECB to the CFDIU
1. Possible Causes
_______________
- CFDIU (1TW)
- wiring
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------
AMM 31-32-00-869-002 Procedure for Class 3 Faults Reading
AMM 31-32-34-000-001 Removal of the CFDIU (1TW)
AMM 31-32-34-400-001 Installation of the CFDIU (1TW)
ASM 31-32/04
3. Fault Confirmation
__________________
A. Test On the CFDS MENU page, get access to the AVIONICS STATUS page (Ref. AMM TASK 31-32-00-869-002).
4. Fault Isolation
_______________
A. If the test gives the maintenance message:
NO ECB DATA:
- replace the CFDIU (1TW), (Ref. AMM TASK 31-32-34-000-001) and (Ref. AMM TASK 31-32-34-400-001).
(1) If the fault continues:
- do a check and repair the wiring from the CFDIU (1TW) pins AA/10F, 10G to the first terminal block , (Ref. ASM 31-32/04).
B. Do the test given in Para. 3.
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞31-32-00∞∞∞∞∞∞∞∞∞∞Page 256
Nov 01/04 CES
TASK 31-32-00-810-850
Failure of the CFDIU Detected by the ADF 1
1. Possible Causes
_______________
- CFDIU (1TW)
- wiring
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
AMM 31-32-34-000-001 Removal of the CFDIU (1TW)
AMM 31-32-34-400-001 Installation of the CFDIU (1TW)
AMM 34-53-00-740-003 BITE Test of the ADF
ASM 31-32/02
3. Fault Confirmation
__________________
A. Make sure that this(these) circuit breaker(s) is(are) closed:
-------------------------------------------------------------------------------PANEL DESIGNATION IDENT. LOCATION -------------------------------------------------------------------------------49VU NAV/ADF/1 1RP1 H14
B. Test Do the BITE test of the ADF (system 1) (Ref. AMM TASK 34-53-00-740-003).
4. Fault Isolation
_______________
A. If the test gives the maintenance message ADF1 NO DATA FROM CFDIU:
- replace the CFDIU (1TW), (Ref. AMM TASK 31-32-34-000-001) and (Ref. AMM TASK 31-32-34-400-001).
(1) If the fault continues:
- do a check and repair the wiring from the CFDIU (1TW) pins AA/2B, 2C to the first terminal block , (Ref. ASM 31-32/02).
B. Do the test given in Para. 3.
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞31-32-00∞∞∞∞∞∞∞∞∞∞Page 257
Nov 01/04R CES
Failure of the CFDIU Detected by the ATC 1
1. Possible Causes
_______________
- CFDIU (1TW)
- wiring
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------
中国航空网 www.aero.cn