R **ON A/C 106-149, 151-199, 201-299, 301-399, 401-499,
TASK 31-21-00-810-807
Loss of the link GPS/CLOCK
1. Possible Causes_______________
- wiring
2. Job Set-up Information______________________
A. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
AMM ASM 34-36-00-740-003 31-21/01 BITE Test of the MMR
3. Fault Confirmation__________________
R **ON A/C 106-149, 151-199, 201-299, 301-399, 401-499,
Post SB 31-1133 For A/C 201-203,
A. Not applicable, the fault is evident.
R **ON A/C 106-149, 151-199, 201-299, 301-399, 401-499,
4. Fault Isolation_______________
R **ON A/C 106-149, 151-199, 201-299, 301-399, 401-499,
Post SB 31-1133 For A/C 201-203,
A. If the fault symptom is identified by the crew observation Clock not counting:
Do the test of the MMR (Ref. AMM TASK 34-36-00-740-003).
(1) If the result to the test is NO - Proceed to the MMR trouble shooting
(2) If the result to the test is YES - Do a check and repair the wiring from the MMR (40RT1) pin AB/9E, 9F to the CLOCK (2FS) pin A/E, F (Ref. ASM 31-21/01).
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1R EFF : 106-149, 151-199, 201-299, 301-399, ∞∞31-21-00∞∞∞∞∞∞∞∞∞∞Page 212
401-499, Aug 01/05 CES
CENTRALIZED FAULT DISPLAY INTERFACE (CFDIU) - FAULT ISOLATION PROCEDURES
________________________________________________________________________
TASK 31-32-00-810-808 Failure of the CFDIU Backup
1. Possible Causes
_______________
- CFDIU (1TW)
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
AMM 31-32-00-740-003 Ground Scanning of the CFDIU AMM 31-32-34-000-001 Removal of the CFDIU (1TW) AMM 31-32-34-400-001 Installation of the CFDIU (1TW)
3. Fault Confirmation
__________________
A. Test Do the ground scanning of the CFDIU (Ref. AMM TASK 31-32-00-740-003).
4. Fault Isolation
_______________
A. If the test gives the maintenance message CFDIU BACKUP:
- replace the CFDIU (1TW), (Ref. AMM TASK 31-32-34-000-001) and (Ref. AMM TASK 31-32-34-400-001).
B. Do the test given in Para. 3.
Loss of the Bus 1 of the CFDIU Detected by the VOR 1
1. Possible Causes
_______________
- CFDIU (1TW)
- wiring
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
AMM 31-32-34-000-001 Removal of the CFDIU (1TW)
AMM 31-32-34-400-001 Installation of the CFDIU (1TW)
AMM 34-55-00-740-002 BITE Test of the VOR/MKR
ASM 31-32/02
3. Fault Confirmation
__________________
A. Make sure that this(these) circuit breaker(s) is(are) closed:
-------------------------------------------------------------------------------PANEL DESIGNATION IDENT. LOCATION -------------------------------------------------------------------------------49VU NAV/VOR/1 2RS1 G13
B. Test Do the BITE test of the VOR/MKR (system 1) (Ref. AMM TASK 34-55-00-740-002).
4. Fault Isolation
_______________
A. If the test gives the maintenance message VOR1 : NO DATA FROM CFDIU:
- replace the CFDIU (1TW), (Ref. AMM TASK 31-32-34-000-001) and (Ref. AMM TASK 31-32-34-400-001).
(1) If the fault continues:
- do a check and repair the wiring from the CFDIU (1TW) pins AA/2B, 2C to the first terminal block , (Ref. ASM 31-32/02).
B. Do the test given in Para. 3.B.
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞31-32-00∞∞∞∞∞∞∞∞∞∞Page 202