 May 01/05 CES CB 9TU/2 and QAR (3TU) connector AA/6D, QAR (3TU) connector AA/5K and ground.

 

 (3) If there is no 115 VDC:
 - do a check and repair if necessary the wiring (Ref. ASM 31-33/01), between:
 CB 8TU/2 and QAR (3TU) connector AC/1, QAR (3TU) connector AC/4 and ground.
 (4) If the fault continues:
 - do a check and repair if necessary the wiring, between: QAR (3TU) connector AA/1E and relay 6RK A/6, Relay 6RK A/6 and relay 8RK A/5, Relay 6RK A/C and relay 8RK A/C, Relay 6RK A/C and QAR (3TU) connector AA/12G, QAR (3TU) connector AA/5G and FDIU (2TU) connector AB/11H, QAR (3TU) connector AA/5D and FDIU (2TU) connector AB/11G, QAR (3TU) connector AA/1A and FDIU (2TU) connector AA/9A, QAR (3TU) connector AA/2A and FDIU (2TU) connector AA/9B.
R **ON A/C 051-099, 151-158, 201-207,
 A. If the test gives the maintenance message QAR:
 - make sure that the CBs 8TU and 9TU are closed,

 - do a check for 28 VDC at the QAR (3TU) connectors A/53 and A/47 (Ref. ASM 31-33/01),

 - do a check for 115 VAC at the QAR (3TU) connectors A/37 and A/38 (Ref. ASM 31-33/01).


 (1) If there is 28 VDC and 115 VAC:
 - replace the QAR (3TU) (Ref. AMM TASK 31-33-52-000-001) and (Ref. AMM TASK 31-33-52-400-001).
 「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1R EFF : 001-049, 051-099, 101-105, 151-158, ∞∞31-33-00∞∞∞∞∞∞∞∞∞∞Page 208
 201-209, May 01/05 CES (2) If there is no 28 VDC:

 

 - do a check of the wiring (Ref. ASM 31-33/01), between:
 CB 9TU and QAR (3TU) connector A/53, R QAR (3TU) connector A/47 and ground.
 (3) If there is no 115 VDC:

 - do a check of the wiring (Ref. ASM 31-33/01), between: CB 8TU and QAR (3TU) connector A/37, QAR (3TU) connector A/38 and ground.

 (4) If the fault continues:


 - do a check and repair the wiring as necessary, between: QAR (3TU) connector A/52 and relay 6RK A/6, Relay 6RK A/6 and relay 8RK A/5, Relay 6RK A/C and relay 8RK A/C, Relay 6RK A/C and QAR (3TU) connector A/51, QAR (3TU) connector A/36 and FDIU (2TU) connector AB/11H, QAR (3TU) connector A/54 and FDIU (2TU) connector AB/11G, QAR (3TU) connector A/55 and FDIU (2TU) connector AA/9A, QAR (3TU) connector A/56 and FDIU (2TU) connector AA/9B.
R **ON A/C 106-149, 210-299, 301-399, 401-499,
 A. If the test gives the maintenance message QAR:
 - make sure that the CBs 5TV and 9TU are closed,

 - do a check for 28 VDC at the QAR (3TU) connectors AA/6D and AA/5K (Ref. ASM 31-33/01),

 - do a check for 115 VAC at the QAR (3TU) connectors AC/1 and AC/4 (Ref. ASM 31-33/01).


 (1) If there is 28 VDC and 115 VAC:
 - replace the QAR (3TU) (Ref. AMM TASK 31-33-52-000-001) and (Ref. AMM TASK 31-33-52-400-001).
 「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1R EFF : 051-099, 106-149, 151-158, 201-207, ∞∞31-33-00∞∞∞∞∞∞∞∞∞∞Page 209
 210-299, 301-399, 401-499, Aug 01/05 CES (2) If there is no 28 VDC:

 

 - do a check and repair if necessary the wiring (Ref. ASM 31-33/01), between:
 CB 9TU/2 and QAR (3TU) connector AA/6D, QAR (3TU) connector AA/5K and ground.
 (3) If there is no 115 VDC:
 - do a check and repair if necessary the wiring (Ref. ASM 31-33/01), between:
 CB 5TV/2 and QAR (3TU) connector AC/1, QAR (3TU) connector AC/4 and ground.
 (4) If the fault continues:
 - do a check and repair if necessary the wiring, between: QAR (3TU) connector AA/1E and relay 6RK A/6, Relay 6RK A/6 and relay 8RK A/5, Relay 6RK A/C and relay 8RK A/C, Relay 6RK A/C and QAR (3TU) connector AA/12G, QAR (3TU) connector AA/5G and FDIMU (10TV) connector AB/11G, QAR (3TU) connector AA/5D and FDIMU (10TV) connector AB/11F, QAR (3TU) connector AA/1A and FDIMU (10TV) connector AA/13C, QAR (3TU) connector AA/2A and FDIMU (10TV) connector AA/13D.
 **ON A/C 159-199,
 A. If the test gives the maintenance message QAR:
 - make sure that the CBs 5TV and 9TU are closed,

 - do a check for 28 VDC at the QAR (3TU) connectors A/53 and A/47 (Ref. ASM 31-33/01),

 - do a check for 115 VAC at the QAR (3TU) connectors A/37 and A/38 (Ref. ASM 31-33/01).


 「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1R EFF : 106-149, 159-199, 210-299, 301-399, ∞∞31-33-00∞∞∞∞∞∞∞∞∞∞Page 210
 401-499, Aug 01/05 CES

 

R (1) If there is 28 VDC and 115 VAC:
R
R - replace the QAR (3TU) (Ref. AMM TASK 31-33-52-000-001) and (Ref.
 