3. Fault Confirmation
__________________
 A. Make sure that this(these) circuit breaker(s) is(are) closed:
 -------------------------------------------------------------------------------PANEL DESIGNATION IDENT. LOCATION -------------------------------------------------------------------------------
R **ON A/C 001-049, 051-099, 101-149, 151-199, 201-299, 301-399,
 49VU L/G/Y BRK/PRESS/IND 61GG C10 R **ON A/C 401-499, 
R 49VU ABCU &/Y BRK/PRESS IND 61GG C10 R **ON A/C ALL
 B. Test Do the operational test of the central warning systems (SDAC) (Ref. AMM TASK 31-50-00-710-001).
 4. Fault Isolation
_______________
 A. If the test gives the maintenance message SDAC1 : LH Y BRK PRESS XDCR 63GG:
 - do a check and repair the:
- wiring between 1853VT92K and 1101VT10F
- wiring between 1853VT92J and 1101VT11B , (Ref. AWM 31-54-70).
 「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞31-54-00∞∞∞∞∞∞∞∞∞∞Page 213
 Aug 01/05 CES
B. Do the test given in Para. 3.B.
 「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞31-54-00∞∞∞∞∞∞∞∞∞∞Page 214
 Aug 01/05R
 CES
 Loss of the R Yellow Brake Pressure-Transducer Input of the SDAC 1 
 1. Possible Causes_______________ 
 - SDAC-1 (1WV1) - wiring 
 2. Job Set-up Information______________________ 
 A. Referenced Information 
 -------------------------------------------------------------------------------REFERENCE DESIGNATION ------------------------------------------------------------------------------- 
AMM AMM AMM ASM  31-50-00-710-001 31-55-34-000-001 31-55-34-400-001 32-44/01 Ground Scanning of the Central Warning SystemRemoval of the SDAC (1WV1,1WV2)Installation of the SDAC (1WV1,1WV2) 
 3. Fault Confirmation__________________ 
 A. Make sure that this(these) circuit breaker(s) is(are) closed: 
 -------------------------------------------------------------------------------PANEL DESIGNATION IDENT. LOCATION ------------------------------------------------------------------------------- 
R  **ON A/C 001-049, 051-099, 101-149, 151-199, 201-299, 301-399, 
 49VU L/G/Y BRK/PRESS/IND  61GG  C10  
R  **ON A/C 401-499,  
R  49VU ABCU &/Y BRK/PRESS IND  61GG  C10  
R  **ON A/C ALL 
 B. Test Do the operational test of the central warning systems (SDAC) (Ref. AMM TASK 31-50-00-710-001).
 4. Fault Isolation
_______________
 A. If the test gives the maintenance message SDAC1 : RH Y BRK PRESS XDCR 62GG:
 - replace the SDAC-1 (1WV1), (Ref. AMM TASK 31-55-34-000-001) and (Ref. AMM TASK 31-55-34-400-001).
 (1) If the fault continues:
 - do a check and repair the wiring from the SDAC 1 (1WV1) pins AE/13G, 13H to the first terminal block , (Ref. ASM 32-44/01).
 B. Do the test given in Para. 3.B.
 「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞31-54-00∞∞∞∞∞∞∞∞∞∞Page 216
 Aug 01/05R
 CES
 Loss of the R Yellow Brake Pressure-Transducer Input of the SDAC 2 
 1. Possible Causes_______________ 
 - SDAC-2 (1WV2) - wiring 
 2. Job Set-up Information______________________ 
 A. Referenced Information 
 -------------------------------------------------------------------------------REFERENCE DESIGNATION ------------------------------------------------------------------------------- 
AMM AMM AMM ASM  31-50-00-710-001 31-55-34-000-001 31-55-34-400-001 32-44/01 Ground Scanning of the Central Warning SystemRemoval of the SDAC (1WV1,1WV2)Installation of the SDAC (1WV1,1WV2) 
 3. Fault Confirmation__________________ 
 A. Make sure that this(these) circuit breaker(s) is(are) closed: 
 -------------------------------------------------------------------------------PANEL DESIGNATION IDENT. LOCATION ------------------------------------------------------------------------------- 
R  **ON A/C 001-049, 051-099, 101-149, 151-199, 201-299, 301-399, 
 49VU L/G/Y BRK/PRESS/IND  61GG  C10  
R  **ON A/C 401-499,  
R  49VU ABCU &/Y BRK/PRESS IND  61GG  C10  
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320 Trouble Shooting Manual 排故手册 指示和记录系统 1(173)