• 热门标签

当前位置: 主页 > 航空资料 > 机务资料 >

时间:2011-03-28 18:30来源:蓝天飞行翻译 作者:航空
曝光台 注意防骗 网曝天猫店富美金盛家居专营店坑蒙拐骗欺诈消费者

 A. Make sure that this(these) circuit breaker(s) is(are) closed:
 -------------------------------------------------------------------------------PANEL DESIGNATION IDENT. LOCATION -------------------------------------------------------------------------------
R **ON A/C 001-049, 051-099, 101-105, 151-199, 201-210, 301-399,
 121VU COM NAV/HF2 1RE2 L13 R **ON A/C 001-049, 051-099, 101-105, 151-199, 201-210, 301-399, 401-499,
 B. Test
 (1) On the CFDS MENU page, get access to the AVIONICS STATUS page (Ref. AMM TASK 31-32-00-869-002).
 「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1R EFF : 001-049, 051-099, 101-105, 151-199, ∞∞31-32-00∞∞∞∞∞∞∞∞∞∞Page A249
 201-210, 301-399, 401-499, Aug 01/05 CES


 4. Fault Isolation
_______________


 A. If the test gives the maintenance message NO HF2 DATA:
 - replace the XCVR-HF, 2 (3RE2) (Ref. AMM TASK 23-11-33-000-001) and (Ref. AMM TASK 23-11-33-400-001).
 (1) If the fault continues:

 - replace the CFDIU (1TW) (Ref. AMM TASK 31-32-34-000-001) and (Ref. AMM TASK 31-32-34-400-001).

 (2) If the fault continues:


 - do a check and repair the wiring from the HF 2 transceiver (3RE2) to the CFDIU (1TW) (Ref. ASM 23-11/02).
 B. Do the test given in Para. 3.B.
 「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1R EFF : 001-049, 051-099, 101-105, 151-199, ∞∞31-32-00∞∞∞∞∞∞∞∞∞∞Page A250
 201-210, 301-399, 401-499, Aug 01/05 CES

 


 TASK 31-32-00-810-909
 Loss of Data from the HF 1 Transceiver to the CFDIU

 1. Possible Causes
_______________
 - XCVR-HF, 1 (3RE1)

 - CFDIU (1TW)

 - wiring


 2. Job Set-up Information
______________________
 A. Referenced Information
 -------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
AMM 23-11-33-000-001 Removal of the HF Transceiver (3RE1, 3RE2)
 AMM 23-11-33-400-001 Installation of the HF Transceiver (3RE1, 3RE2)
 AMM 31-32-00-869-002 Procedure for Class 3 Faults Reading
 AMM 31-32-34-000-001 Removal of the CFDIU (1TW)
 AMM 31-32-34-400-001 Installation of the CFDIU (1TW)
 ASM 23-11/01

 3. Fault Confirmation
__________________
 A. Make sure that this(these) circuit breaker(s) is(are) closed:
 -------------------------------------------------------------------------------PANEL DESIGNATION IDENT. LOCATION -------------------------------------------------------------------------------
R **ON A/C 001-049, 101-105, 151-199,
 49VU COM/HF1 1RE1 HA14 R **ON A/C 051-099, 106-149, 201-299, 301-399,
 49VU COM HF1 1RE1 HA14
 「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞31-32-00∞∞∞∞∞∞∞∞∞∞Page A251
 May 01/05 CES B. Test

 


 (1) On the CFDS MENU page, get access to the AVIONICS STATUS page (Ref. AMM TASK 31-32-00-869-002).
 4. Fault Isolation
_______________
 A. If the test gives the maintenance message NO HF1 DATA:
 - replace the XCVR-HF, 1 (3RE1) (Ref. AMM TASK 23-11-33-000-001) and (Ref. AMM TASK 23-11-33-400-001).
 (1) If the fault continues:

 - replace the CFDIU (1TW) (Ref. AMM TASK 31-32-34-000-001) and (Ref. AMM TASK 31-32-34-400-001).

 (2) If the fault continues:


 - do a check and repair the wiring from the HF 1 transceiver (3RE1) to the CFDIU (1TW) (Ref. ASM 23-11/01).
 B. Do the test given in Para. 3.B.
 「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞31-32-00∞∞∞∞∞∞∞∞∞∞Page A252
 May 01/05R
 CES  Loss of the Bus Output from the AMU to the CFDIU

 


 1. Possible Causes
_______________
 - CFDIU (1TW)

 - AMU (1RN)

 - wiring from the CFDIU (1TW) to the AMU (1RN)


 2. Job Set-up Information
______________________
 A. Referenced Information
 -------------------------------------------------------------------------------REFERENCE DESIGNATION
 -------------------------------------------------------------------------------
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320 Trouble Shooting Manual 排故手册 指示和记录系统 1(46)