• 热门标签

当前位置: 主页 > 航空资料 > 机务资料 >

时间:2011-03-28 18:30来源:蓝天飞行翻译 作者:航空
曝光台 注意防骗 网曝天猫店富美金盛家居专营店坑蒙拐骗欺诈消费者

 (1) If the fault continues:
 - do a check and repair the wiring from the SDAC 2 (1WV2) pins AB/14C, 14D to the first terminal block , (Ref. ASM 24-32/02).
 B. Do the test given in Para. 3.B.

 「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞31-54-00∞∞∞∞∞∞∞∞∞∞Page 280
 Aug 01/05R CES

 

 TASK 31-54-00-810-877
 Loss of the TR 1 VOLTAGE Input of the SDAC 1

 1. Possible Causes
_______________
 - SDAC-1 (1WV1)

 - wiring


 2. Job Set-up Information
______________________
 A. Referenced Information
 -------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
AMM 31-50-00-710-001 Ground Scanning of the Central Warning System
 AMM 31-55-34-000-001 Removal of the SDAC (1WV1,1WV2)
 AMM 31-55-34-400-001 Installation of the SDAC (1WV1,1WV2)
 ASM 24-32/02

 3. Fault Confirmation
__________________
 A. Make sure that this(these) circuit breaker(s) is(are) closed:
 -------------------------------------------------------------------------------PANEL DESIGNATION IDENT. LOCATION -------------------------------------------------------------------------------
123VU TR1/SPLY 2PU1 AB10
 B. Test Do the operational test of the central warning systems (SDAC) (Ref. AMM TASK 31-50-00-710-001).
 4. Fault Isolation
_______________
 A. If the test gives the maintenance message SDAC 1 : NO TR 1 VOLTAGE 1PU1:
 - replace the SDAC-1 (1WV1), (Ref. AMM TASK 31-55-34-000-001) and (Ref. AMM TASK 31-55-34-400-001).
 (1) If the fault continues:
 - do a check and repair the wiring from the SDAC 1 (1WV1) pin AB/6K to the first terminal block , (Ref. ASM 24-32/02).
 B. Do the test given in Para. 3.B.
 「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞31-54-00∞∞∞∞∞∞∞∞∞∞Page 281
 Aug 01/05R CES

 


 Loss of the TR 1 VOLTAGE Input of the SDAC 2
 1. Possible Causes
_______________
 - SDAC-2 (1WV2)

 - wiring


 2. Job Set-up Information
______________________
 A. Referenced Information
 -------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
AMM 31-50-00-710-001 Ground Scanning of the Central Warning System
 AMM 31-55-34-000-001 Removal of the SDAC (1WV1,1WV2)
 AMM 31-55-34-400-001 Installation of the SDAC (1WV1,1WV2)
 ASM 24-32/02

 3. Fault Confirmation
__________________
 A. Make sure that this(these) circuit breaker(s) is(are) closed:
 -------------------------------------------------------------------------------PANEL DESIGNATION IDENT. LOCATION -------------------------------------------------------------------------------
123VU TR1/SPLY 2PU1 AB10
 B. Test Do the operational test of the central warning systems (SDAC) (Ref. AMM TASK 31-50-00-710-001).
 4. Fault Isolation
_______________
 A. If the test gives the maintenance message SDAC 2 : NO TR 1 VOLTAGE 1PU1:
 - replace the SDAC-2 (1WV2), (Ref. AMM TASK 31-55-34-000-001) and (Ref. AMM TASK 31-55-34-400-001).
 (1) If the fault continues:
 - do a check and repair the wiring from the SDAC 2 (1WV2) pin AB/6K to the first terminal block , (Ref. ASM 24-32/02).
 B. Do the test given in Para. 3.B.
 「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞31-54-00∞∞∞∞∞∞∞∞∞∞Page 282
 Aug 01/05R CES

 


 Loss of the ESS TRU CURRENT Bus of the SDAC 1
 1. Possible Causes
_______________
 - SDAC-1 (1WV1)

 - wiring


 2. Job Set-up Information
______________________
 A. Referenced Information
 -------------------------------------------------------------------------------
REFERENCE DESIGNATION
 -------------------------------------------------------------------------------
AMM 31-50-00-710-001 Ground Scanning of the Central Warning System
 AMM 31-55-34-000-001 Removal of the SDAC (1WV1,1WV2)
 AMM 31-55-34-400-001 Installation of the SDAC (1WV1,1WV2)
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320 Trouble Shooting Manual 排故手册 指示和记录系统 1(195)