3. Fault Confirmation
__________________
A. Test Do the operational test of the central warning systems (SDAC) (Ref. AMM TASK 31-50-00-710-001).
4. Fault Isolation
_______________
A. If the test gives the maintenance message SDAC2 : B HYD TEMP XMTR 2381GR:
- replace the SDAC-2 (1WV2), (Ref. AMM TASK 31-55-34-000-001) and (Ref. AMM TASK 31-55-34-400-001).
(1) If the fault continues:
- replace the XMTR-TEMP, B RSVR (2381GR), (Ref. AMM TASK 29-33-11-000-002) and (Ref. AMM TASK 29-33-11-400-002).
(a) If the fault continues:
- do a check and repair the wiring from the SDAC 2 (1WV2) to the Blue reservoir temperature transmitter (2381GR) from pins AB/11A, 11B to pins A/J, K , (Ref. ASM 29-33/01).
B. Do the test given in Para. 3.
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞31-54-00∞∞∞∞∞∞∞∞∞∞Page 266
Aug 01/05R CES
Loss of the GREEN RSVR TEMP Input of the SDAC 1
1. Possible Causes
_______________
- SDAC-1 (1WV1)
- wiring
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
AMM 31-50-00-710-001 Ground Scanning of the Central Warning System
AMM 31-55-34-000-001 Removal of the SDAC (1WV1,1WV2)
AMM 31-55-34-400-001 Installation of the SDAC (1WV1,1WV2)
ASM 29-33/01
3. Fault Confirmation
__________________
A. Test Do the operational test of the central warning systems (SDAC) (Ref. AMM TASK 31-50-00-710-001).
4. Fault Isolation
_______________
A. If the test gives the maintenance message SDAC1 : G HYD TEMP XMTR 1381GR
- replace the SDAC-1 (1WV1), (Ref. AMM TASK 31-55-34-000-001) and (Ref. AMM TASK 31-55-34-400-001).
(1) If the fault continues:
- do a check and repair the wiring from the SDAC 1 (1WV1) pins AB/12A, 12B to the first terminal block , (Ref. ASM 29-33/01).
B. Do the test given in Para. 3.
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞31-54-00∞∞∞∞∞∞∞∞∞∞Page 267
Aug 01/05R
CES Loss of the GREEN RSVR TEMP Input of the SDAC 2
1. Possible Causes
_______________
- SDAC-2 (1WV2)
- wiring
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
AMM 31-50-00-710-001 Ground Scanning of the Central Warning System
AMM 31-55-34-000-001 Removal of the SDAC (1WV1,1WV2)
AMM 31-55-34-400-001 Installation of the SDAC (1WV1,1WV2)
ASM 29-33/01
3. Fault Confirmation
__________________
A. Test Do the operational test of the central warning systems (SDAC) (Ref. AMM TASK 31-50-00-710-001).
4. Fault Isolation
_______________
A. If the test gives the maintenance message SDAC2 : G HYD TEMP XMTR 1381GR
- replace the SDAC-2 (1WV2), (Ref. AMM TASK 31-55-34-000-001) and (Ref. AMM TASK 31-55-34-400-001).
(1) If the fault continues:
- do a check and repair the wiring from the SDAC 2 (1WV2) pins AB/12A, 12B to the first terminal block , (Ref. ASM 29-33/01).
B. Do the test given in Para. 3.
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞31-54-00∞∞∞∞∞∞∞∞∞∞Page 268
Aug 01/05R
CES TASK 31-54-00-810-865 Loss of the SFCC 1 Bus of the SDAC 1
1. Possible Causes
_______________
- SDAC-1 (1WV1)
- wiring
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
AMM 31-50-00-710-001 Ground Scanning of the Central Warning System
AMM 31-55-34-000-001 Removal of the SDAC (1WV1,1WV2)
AMM 31-55-34-400-001 Installation of the SDAC (1WV1,1WV2)
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320 Trouble Shooting Manual 排故手册 指示和记录系统 1(190)