3. Fault Confirmation
__________________
A. Make sure that this(these) circuit breaker(s) is(are) closed:
-------------------------------------------------------------------------------PANEL DESIGNATION IDENT. LOCATION -------------------------------------------------------------------------------
121VU RCDR/ACCLRM 9TU K18
B. Test Do the operational test of the central warning systems (SDAC) (Ref. AMM TASK 31-50-00-710-001).
4. Fault Isolation
_______________
A. If the test gives the maintenance message SDAC1 : ACCELEROMETER 6TU:
- replace the SDAC-1 (1WV1), (Ref. AMM TASK 31-55-34-000-001) and (Ref. AMM TASK 31-55-34-400-001).
(1) If the fault continues:
- do a check of the wiring from the SDAC 1 (1WV1) pins AE/11E, 11F to the first terminal block
(a) If there is no continuity:
- repair the wiring
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞31-54-00∞∞∞∞∞∞∞∞∞∞Page 291
Aug 01/05R CES
(b) If there is continuity:
- do a check of the wiring from the SDAC 1 (1WV1) pins AE/11G, 11H to the first terminal block
1_ If there is no continuity:
- repair the wiring
2_ If there is continuity:
- do a check and repair the wiring from the SDAC 1 (1WV1) pins
AB/11C, 11D to the first terminal block , (Ref. ASM 31-
54/02).
B. Do the test given in Para. 3.
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞31-54-00∞∞∞∞∞∞∞∞∞∞Page 292
Aug 01/05R
CES Loss of the ACCELEROMETER Input of the SDAC 2
1. Possible Causes
_______________
- SDAC-2 (1WV2)
- wiring
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
AMM 31-50-00-710-001 Ground Scanning of the Central Warning System
AMM 31-55-34-000-001 Removal of the SDAC (1WV1,1WV2)
AMM 31-55-34-400-001 Installation of the SDAC (1WV1,1WV2)
ASM 31-54/02
3. Fault Confirmation
__________________
A. Make sure that this(these) circuit breaker(s) is(are) closed:
-------------------------------------------------------------------------------PANEL DESIGNATION IDENT. LOCATION -------------------------------------------------------------------------------
121VU RCDR/ACCLRM 9TU K18
B. Test Do the operational test of the central warning systems (SDAC) (Ref. AMM TASK 31-50-00-710-001).
4. Fault Isolation
_______________
A. If the test gives the maintenance message SDAC2 : ACCELEROMETER 6TU:
- replace the SDAC-2 (1WV2), (Ref. AMM TASK 31-55-34-000-001) and (Ref. AMM TASK 31-55-34-400-001).
(1) If the fault continues:
- do a check of the wiring from the SDAC 2 (1WV2) pins AE/11E, 11F to the first terminal block
(a) If there is no continuity:
- repair the wiring
(b) If there is continuity:
- do a check of the wiring from the SDAC 2 (1WV2) pins AE/11G, 11H to the first terminal block
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞31-54-00∞∞∞∞∞∞∞∞∞∞Page 293
Aug 01/05R CES
1_ If there is no continuity:
- repair the wiring
2_ If there is continuity:
- do a check and repair the wiring from the SDAC 2 (1WV2) pins
AB/11C, 11D to the first terminal block , (Ref. ASM 31-
54/02).
B. Do the test given in Para. 3.
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞31-54-00∞∞∞∞∞∞∞∞∞∞Page 294
Aug 01/05R
CES Failure of the Three Axis Accelerometer
1. Possible Causes
_______________
- ACCELEROMETER-THREE AXIS (6TU)
- wiring 中国航空网 www.aero.cn 航空翻译 www.aviation.cn 本文链接地址:A320 Trouble Shooting Manual 排故手册 指示和记录系统 1(199)