Loss of the CIDS-SDF2 or SDCU Channel 2 Bus Detected by the FWC 1
1. Possible Causes
_______________
- FWC-1 (1WW1)
- wiring
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
AMM 31-50-00-710-001 Ground Scanning of the Central Warning System AMM 31-53-34-000-001 Removal of the Flight Warning Computer (FWC) (1WW1,1WW2) AMM 31-53-34-400-001 Installation of the Flight Warning Computer (FWC) (1WW1,1WW2) ASM 31-52/03
3. Fault Confirmation
__________________
A. Do the ground scanning of the central warning system (FWC) (Ref. AMM TASK 31-50-00-710-001).
4. Fault Isolation
_______________
A. If the test gives the maintenance message:
FWC1 : NO DATA FROM SDCU2
or
FWC1 : NO DATA FROM CIDS-SDF2
- replace the FWC-1 (1WW1) (Ref. AMM TASK 31-53-34-000-001) and (Ref. AMM TASK 31-53-34-400-001).
(1) If the fault continues:
- do a check and repair the wiring from FWC 1 (1WW1) pins AE/8E, 8F to the first terminal block (Ref. ASM 31-52/03).
B. Do the test given in Para. 3.
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞31-53-00∞∞∞∞∞∞∞∞∞∞Page A209
Feb 01/05R CES
Loss of the CIDS-SDF1 or SDCU Channel 1 Bus Detected by the FWC 2
1. Possible Causes
_______________
- FWC-2 (1WW2)
- wiring
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
AMM 31-50-00-710-001 Ground Scanning of the Central Warning System AMM 31-53-34-000-001 Removal of the Flight Warning Computer (FWC) (1WW1,1WW2) AMM 31-53-34-400-001 Installation of the Flight Warning Computer (FWC) (1WW1,1WW2) ASM 31-52/03
3. Fault Confirmation
__________________
A. Do the ground scanning of the central warning system (FWC) (Ref. AMM TASK 31-50-00-710-001).
4. Fault Isolation
_______________
A. If the test gives the maintenance message:
FWC2 : NO DATA FROM SDCU1
or
FWC2 : NO DATA FROM CIDS-SDF1
- replace the FWC-2 (1WW2) (Ref. AMM TASK 31-53-34-000-001) and (Ref. AMM TASK 31-53-34-400-001).
(1) If the fault continues:
- do a check and repair the wiring from FWC 2 (1WW2) pins AB/8E, 8F to the first terminal block (Ref. ASM 31-52/03).
B. Do the test given in Para. 3.
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞31-53-00∞∞∞∞∞∞∞∞∞∞Page A210
Feb 01/05R CES
Loss of the CIDS-SDF2 or SDCU Channel 2 Bus Detected by the FWC 2
1. Possible Causes
_______________
- FWC-2 (1WW2)
- wiring
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
AMM 31-50-00-710-001 Ground Scanning of the Central Warning System AMM 31-53-34-000-001 Removal of the Flight Warning Computer (FWC) (1WW1,1WW2) AMM 31-53-34-400-001 Installation of the Flight Warning Computer (FWC) (1WW1,1WW2) ASM 31-52/03
3. Fault Confirmation
__________________
A. Do the ground scanning of the central warning system (FWC) (Ref. AMM TASK 31-50-00-710-001).
4. Fault Isolation
_______________
A. If the test gives the maintenance message:
FWC2 : NO DATA FROM SDCU2
or
FWC2 : NO DATA FROM CIDS-SDF2
- replace the FWC-2 (1WW2) (Ref. AMM TASK 31-53-34-000-001) and (Ref. AMM TASK 31-53-34-400-001). 中国航空网 www.aero.cn 航空翻译 www.aviation.cn 本文链接地址:A320 Trouble Shooting Manual 排故手册 指示和记录系统 1(151)