_______________
A. If the test gives the maintenance message NO IR 2 DATA:
- replace the CFDIU (1TW), (Ref. AMM TASK 31-32-34-000-001) and (Ref. AMM TASK 31-32-34-400-001).
(1) If the fault continues:
- do a check and repair the wiring from the CFDIU (1TW) pins AB/2D, 2E to the first terminal block , (Ref. ASM 31-32/03).
B. Do the test given in Para. 3.B.
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞31-32-00∞∞∞∞∞∞∞∞∞∞Page 239
Feb 01/00R
CES Loss of the Bus Output from the ATC Transponder 2 to the CFDIU
1. Possible Causes
_______________
- CFDIU (1TW)
- XPDR-ATC/MODE S, 2 (1SH2)
- wiring from the CFDIU (1TW) to the ATC transponder 2 (1SH2)
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION
-------------------------------------------------------------------------------
AMM 31-32-00-869-002 Procedure for Class 3 Faults Reading
AMM 31-32-34-000-001 Removal of the CFDIU (1TW)
AMM 31-32-34-400-001 Installation of the CFDIU (1TW)
AMM 34-52-33-000-001 Removal of the ATC/Mode S Transponder (1SH1, 1SH2)
AMM 34-52-33-400-001 Installation of the ATC/Mode S Transponder
(1SH1,1SH2) ASM 31-32/03
3. Fault Confirmation
__________________
A. Make sure that this(these) circuit breaker(s) is(are) closed:
-------------------------------------------------------------------------------PANEL DESIGNATION IDENT. LOCATION -------------------------------------------------------------------------------
121VU COM NAV/ATC/2 5SH2 K07
B. Test On the CFDS MENU page, get access to the AVIONICS STATUS page (Ref. AMM TASK 31-32-00-869-002).
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞31-32-00∞∞∞∞∞∞∞∞∞∞Page 240
Feb 01/00R
CES
4. Fault Isolation
_______________
A. If the test gives the maintenance message NO ATC 2 DATA:
- replace the CFDIU (1TW), (Ref. AMM TASK 31-32-34-000-001) and (Ref. AMM TASK 31-32-34-400-001).
(1) If the fault continues:
- replace the XPDR-ATC/MODE S, 2 (1SH2), (Ref. AMM TASK 34-52-33-000-001) and (Ref. AMM TASK 34-52-33-400-001).
(a) If the fault continues:
- do a check and repair the wiring from the CFDIU (1TW) to the ATC transponder 2 (1SH2) from pins AB/8H, 8J to pins AB/6C, 6D , (Ref. ASM 31-32/03).
B. Do the test given in Para. 3.B.
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞31-32-00∞∞∞∞∞∞∞∞∞∞Page 241
Feb 01/00R
CES Loss of the Bus Output from the VOR/MKR Receiver 2 to the CFDIU
1. Possible Causes
_______________
- CFDIU (1TW)
- wiring
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
AMM 31-32-00-869-002 Procedure for Class 3 Faults Reading
AMM 31-32-34-000-001 Removal of the CFDIU (1TW)
AMM 31-32-34-400-001 Installation of the CFDIU (1TW)
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320 Trouble Shooting Manual 排故手册 指示和记录系统 1(15)