4. Fault Isolation
_______________
A. If the DMU (1TV) test gives the maintenance message DMU only:
- make sure that the CB 4TV is closed,
- do a check for 115 VAC at the DMU (1TV) connectors AC/1 and AC/7 (Ref. ASM 31-36/01).
(1) If there is 115 VAC:
- replace the DMU (1TV) (Ref. AMM TASK 31-36-34-000-001) and (Ref. AMM TASK 31-36-34-400-001).
(2) If the fault continues:
- do a check of the correct FDIU engine pin programming (Ref. ASM 31-34/03).
(3) If the fault continues:
- do a check and repair the wiring as necessary (Ref. ASM 31-36/01), between:
DMU (1TV) Ground pin AA/15J and ground,
DMU (1TV) Ground pin AA/15K and ground,
DMU (1TV) Ground pin AB/15J and ground,
DMU (1TV) Ground pin AB/15K and ground.
B. Do the test given in paragraph 3.A. again to check the correct operation (no maintenance message display).
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1R EFF : 001-049, 051-099, 101-105, 151-199, ∞∞31-36-00∞∞∞∞∞∞∞∞∞∞Page 203
201-210, May 01/05 CES
R **ON A/C 106-149, 151-199, 201-299, 301-399, 401-499,
TASK 31-36-00-810-802
DAR (2TV) Inoperative
1. Possible Causes
_______________
- DAR (2TV)
- wiring
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------
AMM 31-36-00-740-003 Test of the DAR (2TV)
AMM 31-36-52-000-001 Removal of the Digital AIDS Recorder (DAR) (2TV)
AMM 31-36-52-400-001 Installation of the Digital AIDS Recorder (DAR) (2TV)
ASM 31-36/01
3. Fault Confirmation
__________________ R **ON A/C 106-149, 159-199, 210-299, 301-399, 401-499,
A. Test of the DAR
(1) Reset the DAR
(a) Open the circuit breakers 5TV and 9TU.
(b) Wait for 1 minute.
(c) Close the circuit breakers 5TV and 9TU.
(2) Do the DAR (2TV) test (Ref. AMM TASK 31-36-00-740-003).
**ON A/C 151-158, 201-209,
A. Test of the DAR
(1) Reset the DAR
(a) Open the circuit breakers 4TV and 9TU.
(b) Wait for 1 minute.
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1R EFF : 106-149, 151-199, 201-299, 301-399, ∞∞31-36-00∞∞∞∞∞∞∞∞∞∞Page 204
401-499, Aug 01/05 CES
(c) Close the circuit breakers 4TV and 9TU.
(2) Do the DAR (2TV) test (Ref. AMM TASK 31-36-00-740-003).
R **ON A/C 106-149, 151-199, 201-299, 301-399, 401-499,
4. Fault Isolation
_______________
R **ON A/C 106-149, 211-299, 301-399, 401-499,
A. If the DAR (2TV) do not run:
- make sure that the CBs 5TV and 9TU are closed,
- do a check for 28 VDC at the DAR (2TV) connectors AA/6D and AA/5K (Ref. ASM 31-36/01),
- do a check for 115 VAC at the DAR (2TV) connectors AC/1 and AC/4 (Ref. ASM 31-36/01).
(1) If there is no 28 VDC:
- do a check and repair the wiring as necessary, between CB 9TU/2 and DAR connector AA/6D (Ref. ASM 31-36/01).
(2) If there is no 115 VAC:
- do a check and repair the wiring as necessary, between CB 5TV/2 and DAR connector AC/1 (Ref. ASM 31-36/01).
(3) If there is 28 VDC and 115 VAC:
- replace the DAR (2TV) (Ref. AMM TASK 31-36-52-000-001) and (Ref. AMM TASK 31-36-52-400-001).
(4) If the fault continues:
- do a check and repair the wiring as necessary (Ref. ASM 31-36/01), between:
- DAR (2TV) connector AA/5D and FDIMU (10TV) connector AA/13E,
- DAR (2TV) connector AA/1A and FDIMU (10TV) connector AA/13A,
- DAR (2TV) connector AA/2A and FDIMU (10TV) connector AA/13B,
- DAR (2TV) connector AA/9A and FDIMU (10TV) connector AA/13J,
- DAR (2TV) connector AA/10A and FDIMU (10TV) connector AA/13K,
- DAR (2TV) connector AA/5G and FDIMU (10TV) connector AB/13E,
- DAR (2TV) connector AA/1E and FDIMU (10TV) connector AB/13A,
- DAR (2TV) connector AA/12G and FDIMU (10TV) connector AB/13B,
- DAR (2TV) connector AA/12D and FDIMU (10TV) connector AB/13K,
- DAR (2TV) connector AA/12A and FDIMU (10TV) connector AB/13F, 中国航空网 www.aero.cn 航空翻译 www.aviation.cn 本文链接地址:A320 Trouble Shooting Manual 排故手册 指示和记录系统 1(78)