Loss of the Output Bus from the ACSC2 or the Zone Temperature Controller to the CFDIU
1. Possible Causes
_______________
- CFDIU (1TW)
- wiring
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
AMM 31-32-00-740-009 Read the AVIONICS STATUS on the MCDU
AMM 31-32-34-000-001 Removal of the CFDIU (1TW)
AMM 31-32-34-400-001 Installation of the CFDIU (1TW)
ASM 31-32/05
3. Fault Confirmation
__________________
A. Read the AVIONICS STATUS on the MCDU (Ref. AMM TASK 31-32-00-740-009).
4. Fault Isolation
_______________
A. If the test gives the maintenance message NO ZONE CTL DATA:
- replace the CFDIU (1TW) (Ref. AMM TASK 31-32-34-000-001) and (Ref. AMM TASK 31-32-34-400-001).
(1) If the fault continues:
- do a check and repair the wiring from the CFDIU (1TW) pins AB/2B, 2C to the first terminal block (Ref. ASM 31-32/05).
B. Do the test given in Para. 3.
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞31-32-00∞∞∞∞∞∞∞∞∞∞Page A211
May 01/05R
CES Loss of the Bus Output from the LGCIU 1 to the CFDIU
1. Possible Causes
_______________
- CFDIU (1TW)
- LGCIU-1 (5GA1)
- wiring from the CFDIU (1TW) to the LGCIU 1 (5GA1)
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
AMM 31-32-00-869-002 Procedure for Class 3 Faults Reading
AMM 31-32-34-000-001 Removal of the CFDIU (1TW)
AMM 31-32-34-400-001 Installation of the CFDIU (1TW)
AMM 32-31-71-000-001 Removal of the LGCIU (5GA1, 5GA2)
AMM 32-31-71-400-001 Installation of the LGCIU (5GA1, 5GA2)
ASM 31-32/04
3. Fault Confirmation
__________________
A. Make sure that this(these) circuit breaker(s) is(are) closed:
-------------------------------------------------------------------------------PANEL DESIGNATION IDENT. LOCATION -------------------------------------------------------------------------------49VU L/G/LGCIU/SYS1/NORM 1GA C09
B. Test On the CFDS MENU page, get access to the AVIONICS STATUS page (Ref. AMM TASK 31-32-00-869-002).
4. Fault Isolation
_______________
A. If the test gives the maintenance message NO LGCIU 1 DATA:
- replace the CFDIU (1TW) (Ref. AMM TASK 31-32-34-000-001) and (Ref. AMM TASK 31-32-34-400-001).
(1) If the fault continues:
- replace the LGCIU-1 (5GA1) (Ref. AMM TASK 32-31-71-000-001) and (Ref. AMM TASK 32-31-71-400-001)
(2) If the fault continues:
- do a check and repair the wiring from the CFDIU (1TW) to the LGCIU1 (5GA1) from pins AA/7F, 7G to pins AA/13H, 15H (Ref. ASM 31-32/04).
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞31-32-00∞∞∞∞∞∞∞∞∞∞Page A212
May 01/05R CES
B. Do the test given in Para. 3.B.
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞31-32-00∞∞∞∞∞∞∞∞∞∞Page A213
May 01/05R
CES Loss of the Bus Output from the LGCIU 2 to the CFDIU
1. Possible Causes
_______________
- CFDIU (1TW)
- LGCIU-2 (5GA2)
- wiring from the CFDIU (1TW) to the LGCIU 2 (5GA2)
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
AMM 31-32-00-869-002 Procedure for Class 3 Faults Reading
AMM 31-32-34-000-001 Removal of the CFDIU (1TW)
AMM 31-32-34-400-001 Installation of the CFDIU (1TW)
AMM 32-31-71-000-001 Removal of the LGCIU (5GA1, 5GA2)
AMM 32-31-71-400-001 Installation of the LGCIU (5GA1, 5GA2)