 A. Referenced Information
 -------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
AMM 31-50-00-710-001 Ground Scanning of the Central Warning System
 AMM 31-55-34-000-001 Removal of the SDAC (1WV1,1WV2)
 AMM 31-55-34-400-001 Installation of the SDAC (1WV1,1WV2)
 ASM 79-36/01

 3. Fault Confirmation
__________________
 A. Make sure that this(these) circuit breaker(s) is(are) closed:
 -------------------------------------------------------------------------------PANEL DESIGNATION IDENT. LOCATION -------------------------------------------------------------------------------
121VU ENGINE/ENG2/OIL/PRESS 2EN2 N42
 B. Test Do the operational test of the central warning systems (SDAC) (Ref. AMM TASK 31-50-00-710-001).
 4. Fault Isolation
_______________
 A. If the test gives the maintenance message SDAC2 : ENG2 OIL PRESS XMTR 4003EN:
 - replace the SDAC-2 (1WV2), (Ref. AMM TASK 31-55-34-000-001) and (Ref. AMM TASK 31-55-34-400-001).
 (1) If the fault continues:
 - do a check and repair the wiring from the SDAC 2 (1WV2) pins AE/15G, 15H to the first terminal block , (Ref. ASM 79-36/01).
 B. Do the test given in Para. 3.
 「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞31-54-00∞∞∞∞∞∞∞∞∞∞Page 232
 Aug 01/05R CES

 


 Loss of the BLUE RSVR QTY Input of the SDAC 1
 1. Possible Causes
_______________
 - SDAC-1 (1WV1)

 - wiring


 2. Job Set-up Information
______________________
 A. Referenced Information
 -------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
AMM 31-50-00-710-001 Ground Scanning of the Central Warning System
 AMM 31-55-34-000-001 Removal of the SDAC (1WV1,1WV2)
 AMM 31-55-34-400-001 Installation of the SDAC (1WV1,1WV2)
 ASM 31-54/02

 3. Fault Confirmation
__________________
 A. Make sure that this(these) circuit breaker(s) is(are) closed:
 -------------------------------------------------------------------------------PANEL DESIGNATION IDENT. LOCATION -------------------------------------------------------------------------------
121VU HYDRAULIC/LOW/LVL/IND 1832GQ N32
 B. Test Do the operational test of the central warning systems (SDAC) (Ref. AMM TASK 31-50-00-710-001).
 4. Fault Isolation
_______________
 A. If the test gives the maintenance message SDAC1 : B HYD QTY IND 2000GQ
 - replace the SDAC-1 (1WV1), (Ref. AMM TASK 31-55-34-000-001) and (Ref. AMM TASK 31-55-34-400-001).
 (1) If the fault continues:
 - do a check and repair the wiring from the SDAC 1 (1WV1) pins AB/6D, 6E, 6F to the first terminal block , (Ref. ASM 31-54/02).
 B. Do the test given in Para. 3.B.
 「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞31-54-00∞∞∞∞∞∞∞∞∞∞Page 233
 Aug 01/05R CES

 


 Loss of the BLUE RSVR QTY Input of the SDAC 2
 1. Possible Causes
_______________
 - SDAC-2 (1WV2)

 - wiring


 2. Job Set-up Information
______________________
 A. Referenced Information
 -------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
AMM 31-50-00-710-001 Ground Scanning of the Central Warning System
 AMM 31-55-34-000-001 Removal of the SDAC (1WV1,1WV2)
 AMM 31-55-34-400-001 Installation of the SDAC (1WV1,1WV2)
 ASM 31-54/02

 3. Fault Confirmation
__________________
 A. Make sure that this(these) circuit breaker(s) is(are) closed:
 -------------------------------------------------------------------------------PANEL DESIGNATION IDENT. LOCATION -------------------------------------------------------------------------------
121VU HYDRAULIC/LOW/LVL/IND 1832GQ N32
 B. Test Do the operational test of the central warning systems (SDAC) (Ref. AMM TASK 31-50-00-710-001).
 4. Fault Isolation
_______________
 A. If the test gives the maintenance message SDAC2 : B HYD QTY IND 2000GQ:
 - replace the SDAC-2 (1WV2), (Ref. AMM TASK 31-55-34-000-001) and (Ref. AMM TASK 31-55-34-400-001).
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn