• 热门标签

当前位置: 主页 > 航空资料 > 机务资料 >

时间:2011-03-28 18:30来源:蓝天飞行翻译 作者:航空
曝光台 注意防骗 网曝天猫店富美金盛家居专营店坑蒙拐骗欺诈消费者

 - do the test given in Para. 3. of the initial procedure. 1 If the fault stops:

_


 - replace the computer C. 2 If the fault continues:


_

 - install the computer C

 - remove the computer D

 - do the test given in Para. 3. of the initial procedure. a If the fault stops:

_


 - replace the computer D.
 b If the fault continues:

 

_

 - remove the computers B, C, D and the discrete source A

 - do a check of the wiring for a short to ground


 - install the computers B, C, D and the discrete source A. c If the fault continues:
_

 - continue the initial procedure.
 「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞31-32-00∞∞∞∞∞∞∞∞∞∞Page A281
 May 01/05R
 CES  Failure of the Analog Links

 


 1. Possible Causes

_______________

 2. Job Set-up Information


______________________
 A. Referenced Information
 -------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
31-32-00-991-002 Fig. 202
 3. Fault Confirmation
__________________
 A. Not applicable, refer to the initial procedure.
 4. Fault Isolation
_______________
 (Ref. Fig. 202/TASK 31-32-00-991-002)

 A. Trouble Shooting Procedure for the analog Links.
 Use the procedure that follows to find:

 - if the fault is in one of the receivers (computer B, C or D) of the analog signal (refer to the schematic in the initial procedure to find the receivers related to the analog signal), or

 - if the fault is an unwanted ground of the analog signal.


 A fault in one receiver can change the status of the analog signal and cause a fault detection by all the receivers.
 The initial trouble shooting procedure can only let you know that the possible cause of the fault is the analog source A or the wiring (discontinuity of the analog signal).
 (1) Remove the computer B.

 (2) Do the test given in Para. 3. of the initial procedure.

 (a) if the fault stops:

 - replace the computer B.

 (b) If the fault continues:

 


 - install the computer B
 「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞31-32-00∞∞∞∞∞∞∞∞∞∞Page A282
 May 01/05R CES

 

 Analog Links Failure
 Figure 202/TASK 31-32-00-991-002


 「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞31-32-00∞∞∞∞∞∞∞∞∞∞Page A283
 May 01/05R CES

 

 - remove the computer C


 - do the test given in Para. 3. of the initial procedure. 1 If the fault stops:

_


 - replace the computer C. 2 If the fault continues:


_

 - install the computer C

 - remove the computer D

 - do the test given in Para. 3. of the initial procedure. a If the fault stops:

_


 - replace the computer D.
 b If the fault continues:

 

_

 - remove the computers B, C, D and the analog source A

 - do a check of the wiring for a short to ground


 - install the computers B, C, D and the analog source A. c If the fault continues:
_

 - continue the initial procedure.
 「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞31-32-00∞∞∞∞∞∞∞∞∞∞Page A284
 May 01/05R
 CES  Failure of the Digital Links

 


 1. Possible Causes

_______________

 2. Job Set-up Information


______________________
 A. Referenced Information
 -------------------------------------------------------------------------------
REFERENCE DESIGNATION
 -------------------------------------------------------------------------------
31-32-00-991-003 Fig. 203
 3. Fault Confirmation
__________________
 A. Not applicable, refer to the initial procedure.
 4. Fault Isolation
_______________
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320 Trouble Shooting Manual 排故手册 指示和记录系统 1(55)