D. Make sure that this(these) circuit breaker(s) is(are) open, safetied and tagged
-------------------------------------------------------------------------------PANEL DESIGNATION IDENT. LOCATION -------------------------------------------------------------------------------
49VU L/G/LGCIU/SYS1/NORM 1GA C09 121VU HYDRAULIC/LGCIU/SYS2 2GA Q35 121VU HYDRAULIC/LGCIU/SYS1/GRND SPLY 52GA Q34
4. Procedure
_________ Subtask 32-33-16-420-058
A. Preparation for Installation
(1)
Clean the component interface and/or the adjacent area with a MISCELLANEOUS (Material No. 19-003) made moist with CLEANING AGENTS (Material No. 11-026).
(2)
Make sure that the parts retained from the removed component are clean and in the correct condition.
(3) Do an inspection of the component interface and/or the adjacent area. Subtask 32-33-16-420-052
B. Installation of the MLG Free-Fall Extension Cables (39) and/or (40)
(Ref. Fig. 407/TASK 32-33-16-991-004, 408/TASK 32-33-16-991-005)
(1)
Put the cable(s) (39) and/or (40) around the pulleys and through the structure.
(2)
Attach the cable(s) (39) and/or (40) to the pulley (83).
(3)
When necessary (for RH cables only) install the fairlead(s) (82).
(4)
Release the cable(s) (37) and/or (38) from the structure.
(5)
Connect each cable as necessary to its related cable with the turnbuckle(s) (41).
(6)
Temporarily attach the locking clips (42).
1EFF : ALL 1 32-33-16Page 438 1 1 Feb 01/03R 1 1 1CES 1
(7)
Install these items together:
-
the tubes (75) and the washers (76)
-
the tubes (78) and the washers (79).
(8)
Safety the tubes with the new cotter-pin (77) and cotter-pin (80).
(9)
At the cable pulley assembly on FR 41, install these items together:
-
the cable guard assembly (85)
-
the pins (84), the washers (86) and the nuts (87).
(10)
Safety the nuts (87) with MISCELLANEOUS (Material No. 19-010). Subtask 32-33-16-420-053
C. Installation of the MLG Free-Fall Extension Cables (37) and/or (38) (Ref. Fig. 407/TASK 32-33-16-991-004, 409/TASK 32-33-16-991-009)
(1)
Clean the pressure-seal-flanges (58) and (60) with CLEANING AGENTS (Material No. 11-026) to remove the sealant and paint.
(2)
Put the sleeve (63) and the pressure-seal-flanges (58) and (60) on the applicable cable correctly.
(3)
Put the cable(s) (37) and/or (38) around the pulleys and through the structure.
(4)
Attach the cable(s) (37) and/or (38) to the pulley (65).
(5)
Release the cable(s) (39) and/or (40) from the structure.
(6)
Connect each cable as necessary to its related cable with the turnbuckle(s) (41).
(7)
Temporarily attach the locking clips (42). Subtask 32-33-16-420-054
D. Installation of the Cable Pressure Seals
(1)
Apply the special material SPECIAL MATERIALS (Material No. 05-002) (5.7070.0) to the pressure-seal flanges (58) and (60) and the bolts (62).
(2)
Assemble the cable pressure-seal(s) with these items: