25QA(22QA) 28-21-52-991-001 Fuel Pump Canister 1QM(4QM) and 2QM(3QM) 28-25-00-650-001 Pressure Defuel 28-25-00-650-003 To Drain Remaining Fuel from the Wing Tanks and the
Center Tank 28-25-00-869-001 Fuel Transfer 57-27-11-000-001 Removal of the Access Panel (540AB, 540BB, 540CB,
540DB, 540EB, 540FB, 540GB, 640AB, 640BB, 640CB, 640DB, 640EB, 640FB, 640GB)
57-27-11-400-001 Installation of the Access Panel (540AB, 540BB, 540CB, 540DB, 540EB, 540FB, 540GB, 640AB, 640BB, 640CB, 640DB, 640EB, 640FB, 640GB)
1EFF : ALL 1 28-21-52Page 413 1 1 Feb 01/05 1 1 1CES 1 -------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
**ON A/C 001-049, 051-061, 101-103, 201-203,
28-21-52-991-001 Fig. 401
**ON A/C 301-399,
28-21-52-991-001-B Fig. 401A
R **ON A/C 001-049, 051-099, 101-149, 151-199, 201-299, 401-499, Post SB 28-1077 For A/C 001-049,051-061,101-103,201-203, 28-21-52-991-001-A Fig. 401B **ON A/C ALL
3. Job Set-up
__________
Subtask 28-21-52-941-061
A. Safety Precautions WARNING : OBEY THE SAFETY PROCEDURES WHEN YOU DO WORK IN A FUEL TANK.
_______
(1)
You must obey the fuel safety procedures (Ref. TASK 28-10-00-910-001) when you do work in a fuel tank.
(2)
Make sure that the safety barriers are in position.
1EFF : ALL 1 28-21-52Page 414 1 1 Aug 01/05 1 1 1CES 1 Subtask 28-21-52-865-050
B. Make sure that this(these) circuit breaker(s) is(are) open, safetied and tagged
-------------------------------------------------------------------------------
PANEL DESIGNATION IDENT. LOCATION
-------------------------------------------------------------------------------
R **ON A/C 001-049, 051-099, 101-149, 151-199, 201-299, 401-499,
121VU FUEL/CTR TK/PUMP2 SPLY 30QA P26
121VU FUEL/CTR TK/PUMP1 SPLY 29QA P23
**ON A/C ALL
121VU FUEL/L WING TK/PUMP2 SPLY 7QA N26 121VU FUEL/L WING TK/PUMP1 SPLY 1QA N23 121VU FUEL/R WING TK/PUMP2 SPLY 8QA Q26 121VU FUEL/R WING TK/PUMP1 SPLY 2QA Q23 123VU L WING TK/PUMP 1/STBY SPLY 11QA AD12 123VU R WING TK/PUMP 1/STBY SPLY 12QA AE12
Subtask 28-21-52-860-050
C. Aircraft Maintenance Configuration
(1)
Make sure that the applicable fuel tank is defueled (Ref. TASK 28-25-00-650-001).
(2)
Make sure that the remaining fuel has been drained from the applicable fuel tank (Ref. TASK 28-25-00-650-003).
(3)
Make sure that the access platform is below the applicable access panel 540AB, 640AB.
(4)
Make sure that the applicable access panel 540AB, 640AB is removed (Ref. TASK 28-10-00-910-002), (Ref. TASK 57-27-11-000-001).
(5)
Make sure that the applicable RIB 2 surge door 540BZ, 640BZ is open and that the HOOK-COVER (RIB2-SURGE DOORS) is installed on the door.
1EFF : ALL 1 28-21-52Page 415 1 1 Aug 01/05 1 1 1CES 1
4. Procedure
_________
**ON A/C 001-049, 051-061, 101-103, 201-203,
(Ref. Fig. 401/TASK 28-21-52-991-001)
**ON A/C 301-399,
(Ref. Fig. 401A/TASK 28-21-52-991-001-B) R **ON A/C 001-049, 051-099, 101-149, 151-199, 201-299, 401-499, Post SB 28-1077 For A/C 001-049,051-061,101-103,201-203, (Ref. Fig. 401B/TASK 28-21-52-991-001-A) R **ON A/C 001-049, 051-099, 101-149, 151-199, 201-299, 401-499,
Subtask 28-21-52-560-050
A. Preparation for a Replacement Component WARNING : USE SOLVENTS/CLEANING AGENTS, SEALANTS AND OTHER SPECIAL
_______ MATERIALS ONLY WITH A GOOD SUPPLY OF AIR. OBEY THE MANUFACTURERS INSTRUCTIONS. PUT ON PROTECTIVE CLOTHING. DO NOT GET THEM IN YOUR MOUTH. DO NOT SMOKE. DO NOT BREATHE THE GAS. THESE MATERIALS ARE POISONOUS, FLAMMABLE AND SKIN IRRITANT. GET MEDICAL HELP IF YOUR SKIN OR EYES BECOME IRRITATED.
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM FUEL 燃油3(73)