R 1EFF : 301-399, 1 57-52-00Page 695 1 1 May 01/04 1 1 1CES 1
R  B. Consumable Materials  
R  ------------------------------------------------------------------------------- 
R  REFERENCE  DESIGNATION  
R  ------------------------------------------------------------------------------- 
R  Material No. 08-061A  D  DAN 220  
R  ALUMINIUM FOIL ADHESIVE TAPE (Ref. 20-31-00)  
R  Material No. 11-026  GB  DEF-STAN  68-148/1  
R  SOLVENT GENERAL PURPOSE (Ref. 20-31-00)  
R  Material No. 19-003  USA AMS 3819  
R  LINT-FREE COTTON CLOTH (Ref. 20-31-00)  
R  C. Referenced Information  
R  ------------------------------------------------------------------------------- 
R  REFERENCE  DESIGNATION  
R  -------------------------------------------------------------------------------
R  27-50-00-866-008  Extension of the Flaps on the Ground  
R  27-50-00-866-009  Retraction of the Flaps on the Ground  
R  NTM 57-52-23 PART 9  
R  ASRM 575200  (for corrective action)  
R  57-52-00-991-016  Fig. 616  
R  3. Job Set-up__________  
R  Subtask 57-52-00-941-069  
R  A. Safety Precautions 
R  (1) Put a warning notice on the flap/slat control lever (panel 114VU) to  
R  tell persons not to operate the flaps.  
R  (2) Put the safety barriers in position.  
R  Subtask 57-52-00-860-052  
R  B. Aicraft Maintenance Configuration  
R  WARNING : MAKE SURE THAT THE TRAVEL RANGES OF THE FLIGHT CONTROLS ARE_______  
R  CLEAR. MOVEMENT OF FLIGHT CONTROLS CAN CAUSE INJURY TO PERSONS  
R  AND/OR DAMAGE.  
R  (1) Fully extend the flaps (Ref. TASK 27-50-00-866-008). 
R 1EFF : 301-399, 1 57-52-00Page 696 1 1 May 01/04 1 1 1CES 1
R  (2) Make sure that the LOCKING TOOL - FLAP/SLAT CONTROL LEVER is  
R  installed on the flap/slat control lever on the panel 114VU.  
R  Subtask 57-52-00-865-086  
R  C. Open, safety and tag this(these) circuit breaker(s):  
R  ------------------------------------------------------------------------------- 
R  PANEL DESIGNATION IDENT. LOCATION  
R  ------------------------------------------------------------------------------- 
R  49VU FLIGHT CONTROLS/FLP/CTL AND MONG/SYS1 6CV B07  
R  121VU FLIGHT CONTROLS/FLP/CTL AND/MONG/SYS2 8CV Q21  
R  Subtask 57-52-00-010-067  
R  D. Get Access  
R  (1) Put the access platform in position below the zone 581(681).  
R  (2) Remove the access panel 581AT (681AT) from the upper surface of the  
R  flap.  
R  (3) Remove and discard the covers to the inspection holes in the lower  
R  surface of the flap.  
R  (4) Make sure that the applicable inspection holes are clear of unwanted  
R  material.  
R  4. Procedure_________  
R  (Ref. Fig. 616/TASK 57-52-00-991-016)  
R  CAUTION : BE CAREFUL WHEN YOU DO MAINTENANCE TASKS ON THE WING TRAILING_______  
R  EDGE:  
R  - DO NOT CAUSE DAMAGE TO THE ELECTRICAL CABLE RACEWAYS.  
R  - DO NOT CAUSE DAMAGE TO THE ELECTRICAL CABLE INSTALLATIONS.  
R  - MAKE SURE THAT THE ELECTRICAL CABLES ARE INSTALLED CORRECTLY.  
R  INCORRECT INSTALLATION CAN CAUSE DAMAGE.  
R  Subtask 57-52-00-110-063  
R  A. Cleaning  
R  (1) Use CLEANING AGENTS (Material No. 11-026) and a clean MISCELLANEOUS  
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM WINGS 机翼4(36)