R  - DO NOT CAUSE DAMAGE TO THE ELECTRICAL CABLE INSTALLATIONS. 
R  - MAKE SURE THAT THE ELECTRICAL CABLES ARE INSTALLED CORRECTLY. 
R  INCORRECT INSTALLATION CAN CAUSE DAMAGE. 
R  1. Reason for the Job__________________ 
R  Refer to the MPD TASK: 575223-02 
R  2. Job Set-up Information______________________ 
R  A. Fixtures, Tools, Test and Support Equipment 
R  -------------------------------------------------------------------------------
R  REFERENCE  QTY DESIGNATION 
R  -------------------------------------------------------------------------------
R  No specific  circuit breaker(s) safety clip(s) 
R  No specific  safety barriers 
R  No specific  warning notice 
R  No specific  access platform 2.5 m (8 ft. 2 in.) 

R 1EFF : 301-399, 1 57-52-00Page 695 1 1 May 01/04 1 1 1CES 1


R  B. Consumable Materials 
R  -------------------------------------------------------------------------------
R  REFERENCE  DESIGNATION 
R  -------------------------------------------------------------------------------
R  Material No. 08-061A  D  DAN 220 
R  ALUMINIUM FOIL ADHESIVE TAPE (Ref. 20-31-00) 
R  Material No. 11-026  GB  DEF-STAN  68-148/1 
R  SOLVENT GENERAL PURPOSE (Ref. 20-31-00) 
R  Material No. 19-003  USA AMS 3819 
R  LINT-FREE COTTON CLOTH (Ref. 20-31-00) 
R  C. Referenced Information 
R  -------------------------------------------------------------------------------
R  REFERENCE  DESIGNATION 
R  -------------------------------------------------------------------------------

R  27-50-00-866-008  Extension of the Flaps on the Ground 
R  27-50-00-866-009  Retraction of the Flaps on the Ground 
R  NTM 57-52-23 PART 9 
R  ASRM 575200  (for corrective action) 
R  57-52-00-991-016  Fig. 616 
R  3. Job Set-up__________ 
R  Subtask 57-52-00-941-069 
R  A. Safety Precautions 

R  (1) Put a warning notice on the flap/slat control lever (panel 114VU) to 
R  tell persons not to operate the flaps. 
R  (2) Put the safety barriers in position. 
R  Subtask 57-52-00-860-052 
R  B. Aicraft Maintenance Configuration 
R  WARNING : MAKE SURE THAT THE TRAVEL RANGES OF THE FLIGHT CONTROLS ARE_______ 
R  CLEAR. MOVEMENT OF FLIGHT CONTROLS CAN CAUSE INJURY TO PERSONS 
R  AND/OR DAMAGE. 
R  (1) Fully extend the flaps (Ref. TASK 27-50-00-866-008). 

R 1EFF : 301-399, 1 57-52-00Page 696 1 1 May 01/04 1 1 1CES 1


R  (2) Make sure that the LOCKING TOOL - FLAP/SLAT CONTROL LEVER is 
R  installed on the flap/slat control lever on the panel 114VU. 
R  Subtask 57-52-00-865-086 
R  C. Open, safety and tag this(these) circuit breaker(s): 
R  -------------------------------------------------------------------------------
R  PANEL DESIGNATION IDENT. LOCATION 
R  -------------------------------------------------------------------------------
R  49VU FLIGHT CONTROLS/FLP/CTL AND MONG/SYS1 6CV B07 
R  121VU FLIGHT CONTROLS/FLP/CTL AND/MONG/SYS2 8CV Q21 
R  Subtask 57-52-00-010-067 
R  D. Get Access 
R  (1) Put the access platform in position below the zone 581(681). 
R  (2) Remove the access panel 581AT (681AT) from the upper surface of the 
R  flap. 
R  (3) Remove and discard the covers to the inspection holes in the lower 
R  surface of the flap. 
R  (4) Make sure that the applicable inspection holes are clear of unwanted 
R  material. 
R  4. Procedure_________ 
R  (Ref. Fig. 616/TASK 57-52-00-991-016) 
R  CAUTION : BE CAREFUL WHEN YOU DO MAINTENANCE TASKS ON THE WING TRAILING_______ 
R  EDGE: 
R  - DO NOT CAUSE DAMAGE TO THE ELECTRICAL CABLE RACEWAYS. 
R  - DO NOT CAUSE DAMAGE TO THE ELECTRICAL CABLE INSTALLATIONS. 
R  - MAKE SURE THAT THE ELECTRICAL CABLES ARE INSTALLED CORRECTLY. 
R  INCORRECT INSTALLATION CAN CAUSE DAMAGE. 
R  Subtask 57-52-00-110-063 
R  A. Cleaning 
R  (1) Use CLEANING AGENTS (Material No. 11-026) and a clean MISCELLANEOUS 
 