R  - MAKE SURE THAT THE ELECTRICAL CABLES ARE INSTALLED CORRECTLY. 
R  INCORRECT INSTALLATION CAN CAUSE DAMAGE. 
R  1. Reason for the Job__________________ 
R  Refer to the MPD TASK: 575229-01 
R  2. Job Set-up Information______________________ 
R  A. Fixtures, Tools, Test and Support Equipment 
R  -------------------------------------------------------------------------------
R  REFERENCE  QTY DESIGNATION 
R  -------------------------------------------------------------------------------
R  No specific  circuit breaker(s) safety clip(s) 
R  No specific  safety barriers 
R  No specific  spark-proof lamp 
R  No specific  warning notice 
R  No specific  access platform 3.5 m (11 ft. 6 in.) 
R  98D27803000000  2 LOCKING TOOL - FLAP/SLAT CONTROL LEVER

 

R B. Referenced Information
R -------------------------------------------------------------------------------R REFERENCE DESIGNATION R -------------------------------------------------------------------------------
R  ASRM 575200  (for corrective action) 
R  57-52-00-991-020  Fig. 620 
R  3. Job Set-up__________ 
R  Subtask 57-52-00-941-073 
R  A. Safety Precautions 

R  (1) Put a warning notice on the flap/slat control lever (panel 114VU) to 
R  tell persons not to operate the flaps. 
R  (2) Put the safety barriers in position. 
R  Subtask 57-52-00-860-061 
R  B. Aircraft Maintenance Configuration 
R  (1) Install the LOCKING TOOL - FLAP/SLAT CONTROL LEVER (98D27803000000) 
R  on the flap/slat control lever on the panel 114VU. 
R  Subtask 57-52-00-865-095 
R  C. Open, safety and tag this(these) circuit breaker(s): 
R  -------------------------------------------------------------------------------
R  PANEL  DESIGNATION  IDENT. LOCATION 
R  -------------------------------------------------------------------------------
R  49VU FLIGHT CONTROLS/FLP/CTL AND MONG/SYS1  6CV  B07 
R  121VU FLIGHT CONTROLS/FLP/CTL AND/MONG/SYS2  8CV  Q21 
R  Subtask 57-52-00-010-071 
R  D. Get Access 
R  (1) Put the access platform in position below the pylon at zone 470(480). 
R  (2) Remove the applicable access panel: 
R  - for the left wing, remove 477AL 
R  - for the right wing, remove 487AR.

 

R  (3) Put the spark-proof lamp adjacent to the inspection area. 
R  4. Procedure_________ 
R  (Ref. Fig. 620/TASK 57-52-00-991-020) 
R  CAUTION : BE CAREFUL WHEN YOU DO MAINTENANCE TASKS ON THE WING TRAILING_______ 
R  EDGE: 
R  - DO NOT CAUSE DAMAGE TO THE ELECTRICAL CABLE RACEWAYS. 
R  - DO NOT CAUSE DAMAGE TO THE ELECTRICAL CABLE INSTALLATIONS. 
R  - MAKE SURE THAT THE ELECTRICAL CABLES ARE INSTALLED CORRECTLY. 
R  INCORRECT INSTALLATION CAN CAUSE DAMAGE. 
R  Subtask 57-52-00-210-062 
R  A. Detailed Visual Inspection of Inboard Double Slotted Flap, Attachment 
R  Bracket of Pylon Aft Fairing Including Surrounding Skin, LH/RH 
R  (1) Do an inspection of the attachment bracket and the surrounding skin. 
R  Make sure that: 
R  - there is no damage 
R  - there is no corrosion 
R  - there are no cracks or scores 
R  - the surface protection is in the correct condition. 
R  (2) Do an inspection of the earth bonding lead. Make sure that: 
R  - there is no damage 
R  - there is no corrosion 
R  - it is installed correctly 
R  NOTE : If necessary, refer to the ASRM (Ref. ASRM 575200) for the____ 
R  correct repair procedure. 
R  5. Close-up________ 
R  Subtask 57-52-00-410-073 
R  A. Close Access 
R  (1) Remove the spark-proof lamp from the inspection area. 
R  (2) Make sure that the work area is clean and clear of tool(s) and other 
R  items. 
R  (3) Install the applicable access panel: 
R  - for the left wing, install 477AL 
R  - for the right wing, install 487AR.

 

R Inboard Flap - Attachment Bracket of Pylon Aft Fairing - Inspection Area R Figure 620/TASK 57-52-00-991-020
 