R B. Referenced Information
R -------------------------------------------------------------------------------R REFERENCE DESIGNATION R -------------------------------------------------------------------------------
R 27-50-00-866-008 Extension of the Flaps on the Ground
R 27-50-00-866-009 Retraction of the Flaps on the Ground
R 27-54-61-000-002 Removal of the Flap Kink-Seals
R 27-54-61-400-006 Installation of the Flap Kink-Seals
R ASRM 57520000 (for corrective action)
R 57-52-00-991-022 Fig. 622
R 3. Job Set-up__________
R Subtask 57-52-00-941-075
R A. Safety Precautions
R (1) Put a warning notice on the flap/slat control lever (panel 114VU) to
R tell persons not to operate the flaps.
R (2) Put the safety barriers in position.
R Subtask 57-52-00-860-065
R B. Aircraft Maintenance Configuration
R WARNING : MAKE SURE THAT THE TRAVEL RANGES OF THE FLIGHT CONTROLS ARE_______
R CLEAR. MOVEMENT OF FLIGHT CONTROLS CAN CAUSE INJURY TO PERSONS
R AND/OR DAMAGE.
R (1) Fully extend the flaps (Ref. TASK 27-50-00-866-008).
R (2) Make sure that the LOCKING TOOL - FLAP/SLAT CONTROL LEVER
R (98D27803000000) is installed on the flap/slat control lever on the
R panel 114VU.
R Subtask 57-52-00-865-099
R C. Open, safety and tag this(these) circuit breaker(s):
R -------------------------------------------------------------------------------
R PANEL DESIGNATION IDENT. LOCATION
R -------------------------------------------------------------------------------
R 49VU FLIGHT CONTROLS/FLP/CTL AND MONG/SYS1 6CV B07
R 121VU FLIGHT CONTROLS/FLP/CTL AND/MONG/SYS2 8CV Q21
R Subtask 57-52-00-010-073
R D. Get Access
R (1) Put the access platform in position below the end rib of the inboard
R flap at zone 581(681).
R (2) Remove the flap kink-seals (Ref. TASK 27-54-61-000-002).
R (3) Put the spark-proof lamp adjacent to the inspection area.
R 4. Procedure_________
R (Ref. Fig. 622/TASK 57-52-00-991-022)
R CAUTION : BE CAREFUL WHEN YOU DO MAINTENANCE TASKS ON THE WING TRAILING_______
R EDGE:
R - DO NOT CAUSE DAMAGE TO THE ELECTRICAL CABLE RACEWAYS.
R - DO NOT CAUSE DAMAGE TO THE ELECTRICAL CABLE INSTALLATIONS.
R - MAKE SURE THAT THE ELECTRICAL CABLES ARE INSTALLED CORRECTLY.
R INCORRECT INSTALLATION CAN CAUSE DAMAGE.
R Subtask 57-52-00-210-063
R A. Detailed Inspection of Inboard Double Slotted Flap, End Rib, Including
R Interconnection Strut Attachment Bracket and Lever, RH/LH
R (1) Do an inspection of the end rib, interconnection strut attachment
R bracket and lever. Make sure that:
R - there is no damage
R - there is no corrosion
R - there are no cracks or scores
R - the surface protection is in the correct condition
R - the attachment bolts are tight.
R NOTE : If necessary, refer to the ASRM (Ref. ASRM 57520000) for the____
R correct repair procedure.
R Inboard Flap - End Rib - Inspection Area
R Figure 622/TASK 57-52-00-991-022
1EFF : 301-399, 1 57-52-00 Page A630
1 1 May 01/04
1 1
1CES 1
R 5. Close-up
________
R Subtask 57-52-00-410-075
R A. Close Access
R (1) Remove the spark-proof lamp from the inspection area.
R (2) Make sure that the work area is clean and clear of tool(s) and other
R items.
R (3) Install the flap kink-seals (Ref. TASK 27-54-61-400-006).