1EFF : ALL 1 57-51-37Page 449 1 1 May 01/05 1 1 1CES 1
R  TASK 57-51-37-400-005  
R  Installation of the Access Panels 575KB(675KB), 575LB(675LB), 575MB(675MB)  
R  WARNING : MAKE SURE THAT THE GROUND SAFETY-LOCKS ARE IN POSITION ON THE LANDING_______  
R  GEAR.  
R  WARNING : PUT THE SAFETY DEVICES AND THE WARNING NOTICES IN POSITION BEFORE YOU_______  
R  START A TASK ON OR NEAR:  
R  - THE FLIGHT CONTROLS  
R  - THE FLIGHT CONTROL SURFACES  
R  - THE LANDING GEAR AND THE RELATED DOORS  
R  - COMPONENTS THAT MOVE.  
R  CAUTION : BE CAREFUL WHEN YOU DO MAINTENANCE TASKS ON THE WING TRAILING EDGE:_______  
R  - DO NOT CAUSE DAMAGE TO THE ELECTRICAL CABLE RACEWAYS.  
R  - DO NOT CAUSE DAMAGE TO THE ELECTRICAL CABLE INSTALLATIONS.  
R  - MAKE SURE THAT THE ELECTRICAL CABLES ARE INSTALLED CORRECTLY.  
R  INCORRECT INSTALLATION CAN CAUSE DAMAGE.  
R  1. Reason for the Job__________________  
R  Self Explanatory  
R  2. Job Set-up Information______________________  
R  A. Fixtures, Tools, Test and Support Equipment  
R  ------------------------------------------------------------------------------- 
R  REFERENCE  QTY DESIGNATION  
R  ------------------------------------------------------------------------------- 
R  No specific  safety barriers  
R  No specific  warning notices  
R  No specific  adjustable access platform 4.0 m (13 ft. 1 in.)  
R  No specific  Torque Wrench : range 0.00 to 1.20 m.daN  
R  (0.00 to 9.00 lbf.ft)
R B. Consumable Materials 
R -------------------------------------------------------------------------------R REFERENCE DESIGNATION R -------------------------------------------------------------------------------
R  Material No. 09-016  USA MIL-PRF-81733D TYPE II CLASS B  
R  CORROSION INHIBITING FILLET CONSISTENCY  
R  (Ref. 20-31-00)  
R  Material No. 11-026  GB DEF-STAN 68-148/1  
R  SOLVENT GENERAL PURPOSE (Ref. 20-31-00)  
R  Material No. 19-003  USA AMS 3819  
R  LINT-FREE COTTON CLOTH (Ref. 20-31-00) 
R C. Referenced Information 
R -------------------------------------------------------------------------------R REFERENCE DESIGNATION R -------------------------------------------------------------------------------
R 57-51-37-960-001 R R 57-51-37-991-006 
R 3. Job Set-up
__________ R Subtask 57-51-37-941-059 R A. Safety Precautions 
Replacement of the Lower Trailing Edge Access Panel Seals Fig. 406 
R (1) Make sure that the safety barriers are in position. 
R (2) Make sure that the TOOL-ZERO LOCKING, FLAP SLAT CTL LEVER is R installed on the flap/slat control lever. R (3) Make sure that the warning notices are in position to tell persons 
R not to operate the flaps or slats. R Subtask 57-51-37-860-053 R B. Aircraft Maintenance Configuration R (1) Make sure that the adjustable access platform is in position below 
R the applicable zone 575(675).
R  4. Procedure_________  
R  (Ref. Fig. 406/TASK 57-51-37-991-006)  
R  Subtask 57-51-37-420-056  
R  A. Preparation for Installation  
R  (1) Clean the component interfaces and/or the adjacent area with a  
R  MISCELLANEOUS (Material No. 19-003) made moist with CLEANING AGENTS  
R  (Material No. 11-026).  
R  (2) Do an inspection of the component interface and/or the adjacent area.  
R  (3) Make sure that the parts retained from the removed component are  
R  clean and in the correct condition.  
R  (4) If the access panel seal is damaged, replace it (Ref. TASK 57-51-37- 
R  960-001).  
R  Subtask 57-51-37-420-057  
R  B. Installation of the Access Panels 575KB(675KB), 575LB(675LB),  
R  575MB(675MB)  
R  (1) For the access panel 575KB(675KB):  
R  (a) Put the access panel (1) in position.  
R  (b) Install the bolts (2) but do not tighten. Make sure that you can  
R  move the access panel (1) sufficient to adjust its position.  
R  (c) Set the access panel (1) so that:  
R  - the dimension V is 2.0 mm (0.0787 in.) + 2.3 mm (0.0905 in.)/- 
R  1.5 mm (0.0590 in.) along the full length of the panel  
R  - the dimension X is 4.0 mm (0.1574 in.) + 2.0 mm (0.0787 in.)/- 
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM WINGS 机翼4(6)