R  (e) Fill the clearances around the edges of the access panel (1) with  
R  SEALANTS (Material No. 09-016).  
R  (2) For the access panel 575LB(675LB):  
R  (a) Put the access panel (5) in position.  
R  (b) Install the bolts (6) but do not tighten. Make sure that you can  
R  move the access panel (5) sufficient to adjust its position.  
R  (c) Set the access panel (5) so that:  
R  - the dimension V is 2.0 mm (0.0787 in.) + 2.3 mm (0.0905 in.)/- 
R  1.5 mm (0.0590 in.) along the full length of the panel  
R  - the dimension X is 4.0 mm (0.1574 in.) + 2.0 mm (0.0787 in.)/- 
R  1.0 mm (0.0393 in.) along the full width of the panel  
R  - the dimension Z is 0.0 mm (0.0000 in.) + 0.5 mm (0.0196 in.)  
R  along the full length of the panel seal.  
R  NOTE : If the dimension Z is not in limits, you must adjust the____  
R  position of the panel seal (Ref. TASK 57-51-37-960-001).  
R  (d) TORQUE tighten the bolts (6) to between 0.4 and 0.45 m.daN (35.39  
R  and 39.82 lbf.in).  
R  (e) Fill the clearances around the edges of the access panel (5) with  
R  SEALANTS (Material No. 09-016).  
R  (3) For the access panel 575MB(675MB):  
R  (a) Put the access panel (10) in position.  
R  (b) Install the bolts (11) but do not tighten. Make sure that you can  
R  move the access panel (10) sufficient to adjust its position.  
R  (c) Set the access panel (10) so that:  
R  - the dimension V is 2.0 mm (0.0787 in.) + 2.3 mm (0.0905 in.)/- 
R  1.5 mm (0.0590 in.) along the full length of the panel  
R  - the dimension W is 1.2 mm (0.0472 in.) +/- 0.5 mm (0.0196 in.)  
R  along the full width of the panel  
R  - the dimension X is 4.0 mm (0.1574 in.) + 2.0 mm (0.0787 in.)/- 
R  1.0 mm (0.0393 in.) along the full width of the panel  
R  - the dimension Z is 0.0 mm (0.0000 in.) + 0.5 mm (0.0196 in.)  
R  along the full length of the panel seal.  
R  NOTE : If the dimension Z is not in limits, you must adjust the____  
R  position of the panel seal (Ref. TASK 57-51-37-960-001).
R  (d) TORQUE tighten the bolts (11) to between 0.4 and 0.45 m.daN  
R  (35.39 and 39.82 lbf.in).  
R  (e) Fill the clearances around the edges of the access panel (10)  
R  with SEALANTS (Material No. 09-016).  
R  5. Close-up________  
R  Subtask 57-51-37-942-056  
R  A. Removal of Equipment  
R  (1) Remove the TOOL-ZERO LOCKING, FLAP SLAT CTL LEVER from the flap/slat  
R  control lever.  
R  (2) Make sure that the work area is clean and clear of tool(s) and other  
R  items.  
R  (3) Remove the access platform(s).  
R  (4) Remove the ground support and maintenance equipment, the special and  
R  standard tools and all other items.  
R  (5) Remove the warning notice(s).  
R  (6) Remove the safety barriers.
R TASK 57-51-37-000-006
R  Removal of the Access Panel 575JB(675JB)  
R  WARNING : MAKE SURE THAT THE GROUND SAFETY-LOCKS ARE IN POSITION ON THE LANDING_______  
R  GEAR.  
R  WARNING : PUT THE SAFETY DEVICES AND THE WARNING NOTICES IN POSITION BEFORE YOU_______  
R  START A TASK ON OR NEAR:  
R  - THE FLIGHT CONTROLS  
R  - THE FLIGHT CONTROL SURFACES  
R  - THE LANDING GEAR AND THE RELATED DOORS  
R  - COMPONENTS THAT MOVE.  
R  CAUTION : BE CAREFUL WHEN YOU DO MAINTENANCE TASKS ON THE WING TRAILING EDGE:_______  
R  - DO NOT CAUSE DAMAGE TO THE ELECTRICAL CABLE RACEWAYS.  
R  - DO NOT CAUSE DAMAGE TO THE ELECTRICAL CABLE INSTALLATIONS.  
R  - MAKE SURE THAT THE ELECTRICAL CABLES ARE INSTALLED CORRECTLY.  
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM WINGS 机翼4(7)