5. Close-up
________
(Ref. Fig. 401/TASK 29-13-47-991-001)
**ON A/C 001-049, 051-061, 101-103, 201-203,
Subtask 29-13-47-410-050
A. Close Access
(1)
Make sure that the work area is clean and clear of tool(s) and other items.
(2)
Remove the container from below the compensated slide (1).
(3) Close the access panel 674AB. R **ON A/C 062-099, 104-149, 151-199, 204-299, 301-399, 401-499,
Subtask 29-13-47-410-050-A
A. Close Access
(1)
Make sure that the work area is clean and clear of tool(s) and other items.
(2)
Remove the container from below the compensated slide (1).
(3) Install the access panel 674AB.
**ON A/C ALL
Subtask 29-13-47-942-051
B. Removal of Equipment
(1)
Remove the safety barriers.
(2)
Remove the warning notice(s).
(3)
Remove the access platform(s).
(4)
Remove the ground support and maintenance equipment, the special and standard tools and all other items.
CHECK VALVE - WTB (3170GM) - REMOVAL/INSTALLATION_________________________________________________
TASK 29-13-48-000-001
Removal of the Check Valve 3170GM
WARNING : PUT THE SAFETY DEVICES AND THE WARNING NOTICES IN POSITION BEFORE YOU_______ START A TASK ON OR NEAR: - THE FLIGHT CONTROLS - THE FLIGHT CONTROL SURFACES - THE LANDING GEAR AND THE RELATED DOORS - COMPONENTS THAT MOVE.
WARNING : MAKE SURE THAT THE GROUND SAFETY-LOCKS ARE IN POSITION ON THE LANDING_______ GEAR.
R R R R R CAUTION : BE CAREFUL WHEN YOU DO MAINTENANCE TASKS ON THE WING TRAILING EDGE:_______ - DO NOT CAUSE DAMAGE TO THE ELECTRICAL CABLE RACEWAYS. - DO NOT CAUSE DAMAGE TO THE ELECTRICAL CABLE INSTALLATIONS. - MAKE SURE THAT THE ELECTRICAL CABLES ARE INSTALLED CORRECTLY. INCORRECT INSTALLATION CAN CAUSE DAMAGE.
1. Reason for the Job__________________
Self Explanatory
2. Job Set-up Information______________________
A. Fixtures, Tools, Test and Support Equipment
-------------------------------------------------------------------------------REFERENCE QTY DESIGNATION -------------------------------------------------------------------------------
No specific No specific No specific No specific No specific No specific blanking plugscircuit breaker(s) safety clip(s)safety barrierswarning noticeaccess platform 3.5 m (11 ft. 6 in.)container 5 l (1.3208 USgal)
B. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
27-50-00-866-008 Extension of the Flaps on the Ground 27-60-00-866-002 Extension-Retraction of the Spoilers for Maintenance 29-00-00-910-002 Safety Procedures of the Hydraulic System 29-14-00-614-001 Depressurization of the Hydraulic Reservoirs 29-23-00-860-001 Disconnection of the Isolation Coupling of the Power
Transfer Unit (PTU) R 57-51-37-000-004 Removal of the Access Panels R 575AB/575BB/575CB/575DB/575EB/575FB/575GB/575HB R (675AB/675BB/675CB/675DB/675EB/675FB/675GB/675HB)
29-13-48-991-001 Fig. 401
3. Job Set-up
__________
(Ref. Fig. 401/TASK 29-13-48-991-001)
Subtask 29-13-48-941-053
A. Safety Precautions
WARNING : OBEY THE HYDRAULIC SAFETY PROCEDURES.
_______
(1)
Obey the hydraulic safety procedures (Ref. TASK 29-00-00-910-002).
(2)
Put the safety barriers in position.
(3)
Put a warning notice in position to tell persons not to pressurize the Yellow hydraulic system.
Subtask 29-13-48-860-050
B. Aircraft Maintenance Configuration
(1)
Extend the flaps fully (Ref. TASK 27-50-00-866-008).