FILTER - ENGINE PUMP CASE DRAIN (3084GM) - SERVICING____________________________________________________
TASK 29-13-43-610-041
Servicing of the Engine Pump Case-Drain Filter (3084GM)
WARNING : OBEY THE HYDRAULIC SAFETY PROCEDURES._______
WARNING : DO NOT TOUCH THE HYDRAULIC SYSTEM COMPONENTS FOR A SHORT TIME AFTER_______ THE ENGINE IS SHUTDOWN. THE ENGINE COMPONENTS STAY HOT FOR SOME TIME AND CAN CAUSE INJURY.
CAUTION : DO NOT LET HYDRAULIC FLUID FALL ON THE ENGINE. UNWANTED HYDRAULIC_______ FLUID MUST BE REMOVED IMMEDIATELY WITH A CLEAN LINT FREE CLOTH. THE FLUID CAN CAUSE DAMAGE TO THE SURFACE PROTECTION AND TO SOME PARTS.
1. Reason for the Job__________________
Self Explanatory
2. Job Set-up Information______________________
A. Fixtures, Tools, Test and Support Equipment
-------------------------------------------------------------------------------REFERENCE QTY DESIGNATION -------------------------------------------------------------------------------
No specific No specific No specific warning notice(s)access platform 1.5 m (4 ft. 11 in.)container 5 l (1.3208 USgal)
B. Consumable Materials
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
No specific corrosion resistant steel lockwire dia 0.8 mm (0.032 in.)
R C. Expendable Parts
R R R -------------------------------------------------------------------------------FIG.ITEM |DESIGNATION |IPC-CSN -------------------------------------------------------------------------------
R 5 filter element 29-13-43 02 -020
R D. Referenced Information
-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------
12-12-29-611-001 Fill the Hydraulic Fluid Reservoir with a Hand Pump
12-12-29-611-002 Fill the Hydraulic Fluid Reservoir with a Hydraulic
Service Cart
29-00-00-280-006 Check of the Green or Yellow Hydraulic System after
Operation in a Possible Cavitation Condition of the
Engine Pump
29-13-00-710-002 Operational Test of the Yellow Hydraulic System
29-14-00-614-001 Depressurization of the Hydraulic Reservoirs
29-14-00-614-002 Pressurization of the Hydraulic Reservoirs through
the Ground Connector
29-24-00-864-001 Depressurize the Yellow Hydraulic System
29-13-43-991-904 Fig. 301
FOR FIN 1000EM2
71-13-00-010-040 Opening of the Fan Cowl Doors
71-13-00-410-040 Closing of the Fan Cowl Doors
3. Job Set-up__________
Subtask 29-13-43-860-054
A. Aircraft Maintenance Configuration
(1)
Depressurize the Yellow hydraulic system (Ref. TASK 29-24-00-864-001).
(2)
Depressurize the Yellow hydraulic reservoir (Ref. TASK 29-14-00-614-001).
(3)
Put warning notice(s) in position to tell persons not to pressurize the Yellow hydraulic system: - on the ground service panel 198CB.
(4)
Put warning notice(s) on the access door 195BB to tell persons not to pressurize the Yellow hydraulic reservoir.
Subtask 29-13-43-941-056
B. Safety Precautions
(1)
On the center pedestal, on the ENG panel 115VU:
-put warning notice(s) to tell persons not to start the engine.
(2)
Make sure that the engine 1(2) shutdown occurred not less than 5 minutes before you do this procedure.
(3)
Put warning notice(s) in position to tell persons not to pressurize the Yellow hydraulic system:
-in the cockpit, on the HYD section of the overhead panel 40VU.
(4)
On the overhead maintenance panel 50VU: