(7)
Connect the upper case drain hose/tube (15) to the union (20) on the filter assembly (30).
(8)
TORQUE the coupling nut on the upper case drain hose (15) to between
2.42 and 2.76 m.daN (17.84 and 20.35 lbf.ft).
NOTE : Use a second wrench to hold the union (20) when you TORQUE the
____
coupling nut.
R (9) Put the bulkhead nut (35) and the new (25) on the elbow (40).
(10) Install the elbow (40) on the filter assembly (30), as follows:
(a) Turn the elbow until the packing (25) is against the filter assembly (30).
NOTE : The elbow must point forward and be in the horizontal
____
position.
(b)
Turn the bulkhead nut (35) until it is against the filter assembly (30).
(c)
TORQUE the bulkhead nut (35) to between 2.03 and 2.26 m.daN
(14.97 and 16.66 lbf.ft).
NOTE : Use a second wrench to hold the elbow (40) when you TORQUE
____
the bulkhead nut (35).
(11)
Attach the lower case drain hose (45) to the elbow (40).
(12)
TORQUE the coupling nut on the lower case drain hose (45) to between
2.42 and 2.76 m.daN (17.84 and 20.35 lbf.ft).
NOTE : Use a second wrench to hold the elbow (40) when you TORQUE the
____
coupling nut on the hose.
Subtask 29-13-43-710-052
B. Operational Test
(1)
Pressurize the Yellow hydraulic reservoir (Ref. TASK 29-14-00-614-002).
(2)
Pressurize the Yellow hydraulic system (Ref. TASK 29-23-00-863-002).
(3)
Do an operational test of the Yellow hydraulic system (Ref. TASK 29-13-00-710-002).
(4)
During the dry motoring of the engine 2, make sure that:
-there are no leaks from the case drain filter,
-the clogging indicator of the filter is not out.
(5)
Stop the dry motoring of the engine 2.
5. Close-up
________
Subtask 29-13-43-410-053
A. Close Access
(1)
Remove the warning notice(s).
(2)
Remove the access platform(s).
(3)
Make sure that the work area is clean and clear of tool(s) and other items.
(4)
Close the left fan cowl door
FOR 1000EM2 R close the door 447AL (Ref. TASK 71-13-00-410-040).
(5) Close the door 195BB.
FILTER - LP (3002GM) - SERVICING
________________________________
TASK 29-13-44-610-001
Servicing of the LP-Filter (3002GM)
WARNING : MAKE SURE THAT THE GROUND SAFETY-LOCKS ARE IN POSITION ON THE LANDING
_______
GEAR.
WARNING : MAKE SURE THAT THE TRAVEL RANGES OF THE FLIGHT CONTROL SURFACES ARE
_______
CLEAR BEFORE YOU PRESSURIZE/DEPRESSURIZE A HYDRAULIC SYSTEM.
1.
Reason for the Job
__________________
Self Explanatory
2.
Job Set-up Information
______________________
A. Fixtures, Tools, Test and Support Equipment
-------------------------------------------------------------------------------
REFERENCE QTY DESIGNATION
-------------------------------------------------------------------------------
No specific circuit breaker(s) safety clip(s)
No specific warning notices
No specific container 3.0 l (0.7925 USgal)
B. Consumable Materials
-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------
No specific lockwire 0.8 mm (0.032 in.)
R Material No. 02-003 F NSA 307110 TYPE 4 HYDRAULIC FLUID (PHOSPHATE ESTER BASE) (Ref. 20-31-00)
C. Expendable Parts
-------------------------------------------------------------------------------
FIG.ITEM |DESIGNATION |IPC-CSN
-------------------------------------------------------------------------------
2 O-ring 29-13-44 01 -020 4 filter element 29-13-44 01 -030 D. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
12-12-29-611-001 Fill the Hydraulic Fluid Reservoir with a Hand Pump 29-00-00-864-001 Put the Related Hydraulic System in the Depressurized
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM HYDRAULIC POWER 液压4(53)