 APU to supply the reservoir  - the pressure in each reservoir
 pressurizing system (Ref. TASK  increases to between 20 and 40 psig.
 36-12-00-710-001).
 9. Stop the operation of the APU
 (Ref. TASK 49-00-00-860-009).
 10. Connect the ground air supply to
 the ground connector of the
 reservoir pressurization unit
 1360GM.
 11. On the ground connector:
 - open the ground connector.
 12. Pressurize the reservoirs of the  On the air pressure gages:
 hydraulic systems to 50 psig  - the pressure in the reservoirs
 (Ref. TASK 29-14-00-614-002).  increases to 50 psig. 

R 1EFF : 001-049, 101-105, 151-199, 201-210, 1 29-14-00Page 504 1 1 May 01/05 1 1 1CES 1

 **ON A/C 051-099,


 Subtask 29-14-00-720-050
 A. Do this test:
 -------------------------------------------------------------------------------ACTION RESULT -------------------------------------------------------------------------------
1. On the ground air supply:
 -set the supply at 5 bar (72.5 psi).
 2.
 Pressurize the reservoirs of the three hydraulic systems (Ref. TASK 29-14-00-614-002).

3.
 On the ground air supply:


-stop the supply of air to the reservoir pressurizing system.
-disconnect the ground supply from the ground connector but keep the ground connector open.
 4. On the ground connector:
 -close the ground connector.
 5. On the water separator:
-push the drain valve in and hold it in the open position.
-release the drain valve of the water separator and allow it to go to the closed position.
 6.
 Depressurize the reservoirs of the three hydraulic systems (Ref. TASK 29-14-00-614-001).

7.
 Start the APU (Ref. TASK 49-00-00-860-003).

 8.
 Set the bleed air supply from the APU to supply the reservoir pressurizing system (Ref. TASK 36-12-00-710-001).


On the air pressure gages:
-
the pressure in each reservoirincreases to 50 psig.

On the air pressure gages:

-
the pressure in the reservoirs isconstant.


On the air pressure gages:
-
the pressure in the reservoirs isconstant.

On the air pressure gages:

-
the pressure in the reservoirsdecreases to zero.

On the air pressure gages:

-
the pressure in each reservoirincreases to between 20 and 40 psig.


 1EFF : 051-099, 1 29-14-00Page 505 1 1 Aug 01/05R 1 1 1CES 1


 -------------------------------------------------------------------------------
ACTION RESULT -------------------------------------------------------------------------------
9.
 Stop the operation of the APU
 (Ref. TASK 49-00-00-860-004).


 10.
 Connect the ground air supply to
 the ground connector of the
 reservoir pressurization unit
 1360GM.


 11.
 On the ground connector:
 - open the ground connector.


 12.
 Pressurize the reservoirs of the  On the air pressure gages:
 hydraulic systems to 50 psig - the pressure in the reservoirs
 (Ref. TASK 29-14-00-614-002). increases to 50 psig.

 


R  **ON A/C 106-149, 211-299, 301-399, 401-499,
 Subtask 29-14-00-720-050-B
 A. Do this test:
 -------------------------------------------------------------------------------ACTION RESULT -------------------------------------------------------------------------------
1. On the ground air supply:
 -set the supply at 5 bar (72.5
 psi).

 2.
 Pressurize the reservoirs of the  On the air pressure gages:
 three hydraulic systems - the pressure in each reservoir
 (Ref. TASK 29-14-00-614-002). increases to 50 psig.


 3.
 On the ground air supply: On the air pressure gages:


 -stop the supply of air to the  - the pressure in the reservoirs is reservoir pressurizing system. constant.
 -disconnect the ground supply
 from the ground connector but
 keep the ground connector open.

 4. On the ground connector:
 -close the ground connector.
R 1EFF : 051-099, 106-149, 211-299, 301-399, 1 29-14-00Page 506 1401-499, 1Aug 01/05 1 1 1CES 1


 -------------------------------------------------------------------------------ACTION RESULT -------------------------------------------------------------------------------
5. On the water separator:
-push the drain valve in and hold it in the open position.
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM HYDRAULIC POWER 液压4(109)