(5)
Put a container below the reservoir.
4. Procedure
_________
**ON A/C 001-003, 051-054,
(Ref. Fig. 403/TASK 29-13-41-991-005) R **ON A/C 004-049, 055-099, 101-149, 151-199, 201-299, 301-399, 401-499,
(Ref. Fig. 403A/TASK 29-13-41-991-005-A)
**ON A/C ALL
Subtask 29-13-41-020-051
A. Removal of the Quantity Indicator
(1)
Disconnect the electrical connector (6).
(2)
Put blanking caps on the disconnected electrical connector (6) and on the receptacle.
(3)
Remove the bolts (5) and the washers (4).
(4)
Remove the quantity indicator (3) from the reservoir (1).
Quantity Indicator and Low Level Switch
Figure 403/TASK 29-13-41-991-005
R 1EFF : 001-003, 051-054, 1 29-13-41Page 423 1 1 May 01/05 1 1 1CES 1
Quantity Indicator and Low Level Switch Figure 403A/TASK 29-13-41-991-005-A
R 1EFF : 004-049, 055-099, 101-149, 151-199, 1 29-13-41Page 424 1201-299, 301-399, 401-499, 1Aug 01/05 1 1 1CES 1
(5)
Discard the O-ring (2).
(6)
Put a blanking plug in the port of the reservoir (1).
(7)
Put the quantity indicator (3) into a plastic bag to keep it clean.
1EFF : ALL 1 29-13-41Page 425 1 1 Nov 01/98R 1 1 1CES 1
TASK 29-13-41-400-003 Installation of the Quantity Indicator of the Yellow Hydraulic Reservoir WARNING : MAKE SURE THAT THE GROUND SAFETY-LOCKS ARE IN POSITION ON THE LANDING
_______
GEAR.
1.
Reason for the Job
__________________
Self Explanatory
2.
Job Set-up Information
______________________
A. Fixtures, Tools, Test and Support Equipment
-------------------------------------------------------------------------------
REFERENCE QTY DESIGNATION
-------------------------------------------------------------------------------
No specific container
No specific warning notices
B. Consumable Materials
-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------
R Material No. 02-003 F NSA 307110 TYPE 4 HYDRAULIC FLUID (PHOSPHATE ESTER BASE) (Ref. 20-31-00)
C. Expendable Parts
-------------------------------------------------------------------------------
FIG.ITEM |DESIGNATION |IPC-CSN
-------------------------------------------------------------------------------
2 O-ring 29-13-41 01 -040 2 O-ring 29-13-41 01A-040 D. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
12-12-29-611-001 Fill the Hydraulic Fluid Reservoir with a Hand Pump
12-12-29-611-002 Fill the Hydraulic Fluid Reservoir with a Hydraulic
Service Cart
24-41-00-861-002 Energize the Aircraft Electrical Circuits from the
External Power
24-41-00-862-002 De-energize the Aircraft Electrical Circuits Supplied
from the External Power
29-00-00-864-001 Put the Related Hydraulic System in the Depressurized
Configuration before Maintenance Action
29-00-00-910-002 Safety Procedures of the Hydraulic System
29-10-00-863-002 Pressurize the Yellow Hydraulic System
29-10-00-864-002 Depressurize the Yellow Hydraulic System
29-14-00-614-001 Depressurization of the Hydraulic Reservoirs
29-14-00-614-002 Pressurization of the Hydraulic Reservoirs through
the Ground Connector
29-23-00-860-001 Disconnection of the Isolation Coupling of the Power
Transfer Unit (PTU)
29-23-00-860-002 Connection of the Isolation Coupling of the Power
Transfer Unit (PTU)
29-31-00-710-001 Functional Check of Reservoir Low Level Warning
31-60-00-860-001 EIS Start Procedure
31-60-00-860-002 EIS Stop Procedure
**ON A/C 001-003, 051-054, 29-13-41-991-005 Fig. 403 R **ON A/C 004-049, 055-099, 101-149, 151-199, 201-299, 301-399, 401-499, 29-13-41-991-005-A Fig. 403A
**ON A/C ALL
3. Job Set-up
__________
Subtask 29-13-41-865-058
A. Make sure that this(these) circuit breaker(s) is(are) open, safetied and tagged
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM HYDRAULIC POWER 液压4(39)