 Drain the reservoir of the Yellow hydraulic system (Ref. TASK 29-10-00-680-002).

 (5)
 Put a container below the reservoir.


 4. Procedure
_________
 **ON A/C 001-003, 051-054,

 (Ref. Fig. 403/TASK 29-13-41-991-005) R **ON A/C 004-049, 055-099, 101-149, 151-199, 201-299, 301-399, 401-499,
 (Ref. Fig. 403A/TASK 29-13-41-991-005-A)
 **ON A/C ALL

 Subtask 29-13-41-020-051
 A. Removal of the Quantity Indicator
 (1)
 Disconnect the electrical connector (6).

 (2)
 Put blanking caps on the disconnected electrical connector (6) and on the receptacle.

 (3)
 Remove the bolts (5) and the washers (4).

 (4)
 Remove the quantity indicator (3) from the reservoir (1).

 


 Quantity Indicator and Low Level Switch
 Figure 403/TASK 29-13-41-991-005

R 1EFF : 001-003, 051-054, 1 29-13-41Page 423 1 1 May 01/05 1 1 1CES 1


 Quantity Indicator and Low Level Switch Figure 403A/TASK 29-13-41-991-005-A
R 1EFF : 004-049, 055-099, 101-149, 151-199, 1 29-13-41Page 424 1201-299, 301-399, 401-499, 1Aug 01/05 1 1 1CES 1


 (5)
 Discard the O-ring (2).

 (6)
 Put a blanking plug in the port of the reservoir (1).

 (7)
 Put the quantity indicator (3) into a plastic bag to keep it clean.


 1EFF : ALL 1 29-13-41Page 425 1 1 Nov 01/98R 1 1 1CES 1


 TASK 29-13-41-400-003 Installation of the Quantity Indicator of the Yellow Hydraulic Reservoir WARNING : MAKE SURE THAT THE GROUND SAFETY-LOCKS ARE IN POSITION ON THE LANDING
_______
 GEAR.

 1.
 Reason for the Job

__________________
 Self Explanatory


 2.
 Job Set-up Information


______________________
 A. Fixtures, Tools, Test and Support Equipment
 -------------------------------------------------------------------------------
REFERENCE  QTY DESIGNATION
 -------------------------------------------------------------------------------
No specific container
 No specific warning notices

 B. Consumable Materials
 -------------------------------------------------------------------------------
REFERENCE  DESIGNATION
 -------------------------------------------------------------------------------
R  Material No. 02-003 F NSA 307110 TYPE 4 HYDRAULIC FLUID (PHOSPHATE ESTER BASE) (Ref. 20-31-00)
 C. Expendable Parts
 -------------------------------------------------------------------------------
FIG.ITEM |DESIGNATION  |IPC-CSN
 -------------------------------------------------------------------------------
2 O-ring 29-13-41 01 -040 2 O-ring 29-13-41 01A-040 D. Referenced Information


 -------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
12-12-29-611-001  Fill the Hydraulic Fluid Reservoir with a Hand Pump
 12-12-29-611-002  Fill the Hydraulic Fluid Reservoir with a Hydraulic
 Service Cart
 24-41-00-861-002  Energize the Aircraft Electrical Circuits from the
 External Power
 24-41-00-862-002  De-energize the Aircraft Electrical Circuits Supplied
 from the External Power
 29-00-00-864-001  Put the Related Hydraulic System in the Depressurized
 Configuration before Maintenance Action
 29-00-00-910-002  Safety Procedures of the Hydraulic System
 29-10-00-863-002  Pressurize the Yellow Hydraulic System
 29-10-00-864-002  Depressurize the Yellow Hydraulic System
 29-14-00-614-001  Depressurization of the Hydraulic Reservoirs
 29-14-00-614-002  Pressurization of the Hydraulic Reservoirs through
 the Ground Connector
 29-23-00-860-001  Disconnection of the Isolation Coupling of the Power
 Transfer Unit (PTU)
 29-23-00-860-002  Connection of the Isolation Coupling of the Power
 Transfer Unit (PTU)
 29-31-00-710-001  Functional Check of Reservoir Low Level Warning
 31-60-00-860-001  EIS Start Procedure
 31-60-00-860-002  EIS Stop Procedure

 **ON A/C 001-003, 051-054, 29-13-41-991-005 Fig. 403 R **ON A/C 004-049, 055-099, 101-149, 151-199, 201-299, 301-399, 401-499, 29-13-41-991-005-A Fig. 403A


 **ON A/C ALL
 3. Job Set-up
__________
 Subtask 29-13-41-865-058
 A. Make sure that this(these) circuit breaker(s) is(are) open, safetied and tagged
 