TASK 29-14-00-614-002
Pressurization of the Hydraulic Reservoirs through the Ground Connector
1. Reason for the Job
__________________
To pressurize the hydraulic reservoirs through the ground connector.
NOTE : The reservoirs are pressurized through the air pressurization
____
manifold, thus they are pressurized at the same time.
2. Job Set-up Information
______________________
A. Fixtures, Tools, Test and Support Equipment
-------------------------------------------------------------------------------
REFERENCE QTY DESIGNATION
-------------------------------------------------------------------------------
No specific circuit breaker(s) safety clip(s)
R No specific Torque Wrench : range 0.00 to 1.20 m.daN
R (0.00 to 9.00 lbf.ft) 98D29003501000 1 FILL UNIT - AIR
B. Referenced Information
-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------
29-00-00-870-010 Ram Air Turbine System Bleeding Procedure
29-10-00-200-002 Check Reservoir Air Pressure on Reservoir Gauge
32-12-00-010-001 Open the Main Gear Doors for Access
32-12-00-410-001 Close the Main Gear Doors after Access
29-14-00-991-001 Fig. 201
29-14-00-991-002 Fig. 202
3. Job Set-up
__________
(Ref. Fig. 201/TASK 29-14-00-991-001)
Subtask 29-14-00-865-060
A. Open, safety and tag this(these) circuit breaker(s):
-------------------------------------------------------------------------------PANEL DESIGNATION IDENT. LOCATION -------------------------------------------------------------------------------49VU HYD/HYD PWR/B WARN/& CTL 2702GJ C12 121VU HYDRAULIC/HYD POWER/Y 3803GX N30 123VU B HYD/ELEC PUMP 2701GJ AB09 123VU Y HYD/ELEC/PUMP 3802GX AB06
R 123VU Y HYD/ELEC/ELEC PUMP/NORM 3801GX AB03
Subtask 29-14-00-010-051
B. Get Access
(1)
Open the applicable access door: For the ground service panel of the Green hydraulic system
-197CB For the ground service panel of the Blue hydraulic system
-197EB For the ground service panel of the Yellow hydraulic system
-198CB.
(2)
Open the access doors 195BB, 196BB and 197FB.
(3)
Open one of the main doors of the main gear (Ref. TASK 32-12-00-010-001).
Subtask 29-14-00-869-051
C. Make sure that the applicable reservoir depressurization valve (1087GM, 2087GM or 3087GM) is closed.
4. Procedure
_________ (Ref. Fig. 202/TASK 29-14-00-991-002) R **ON A/C 001-049, 051-061, 101-105, 201-203,
Subtask 29-14-00-614-050
A. Pressurizing NOTE : If the message HYD B RSVR LO AIR PR is shown on the upper ECAM DU
____ after you have completed the task, you must open and close the CB 2386GH, HYDRAULIC/B RSVR/PRESS/XMTR on panel 121VU, location P34 to reset the system.
(1)
Remove the cap from the ground connector.
(2)
Connect the FILL UNIT - AIR (98D29003501000) to the ground connector. NOTE : If the pressurizing tool is not available, you can use an
____ alternative supply of air. The supply must have a pressure of 5 bar (75 psi) and it must have a filter of 5 microns or better.
(3)
Turn the nut counterclockwise to open the ground connector.
(4)
Fill the reservoir with air until 50 psi is shown on the reservoir pressure gages 1383GM, 2383GM and 3383GM.
(5)
Turn the nut clockwise to close the ground connector.
(6)
TORQUE the nut to 0.15 m.daN (13.27 lbf.in). NOTE : Obey the limits (Ref. TASK 29-10-00-200-002), if there is a
____ decrease of the air pressure in the reservoirs.
Location of Pressurization Components
Figure 202/TASK 29-14-00-991-002
1EFF : ALL 1 29-14-00 Page 208
1 1 Feb 01/98
1 1
1CES 1
R **ON A/C 062-099, 106-149, 151-199, 204-299, 301-399, 401-499,
Subtask 29-14-00-614-050-A
A. Pressurizing
(1)
Remove the cap from the ground connector.
(2)
Connect the FILL UNIT - AIR (98D29003501000) to the ground connector. NOTE : If the pressurizing tool is not available, you can use an
____ alternative supply of air. The supply must have a pressure of 5 bar (75 psi) and it must have a filter of 5 microns or better.
(3)
Turn the nut counterclockwise to open the ground connector.