R  (4) Depressurize the reservoir of the Yellow hydraulic system (Ref. TASK 
R  29-14-00-614-001). 
R  (5) Disconnect the isolation coupling of the the Power Transfer Unit 
R  (PTU) (Ref. TASK 29-23-00-860-001). 
R  (6) Put the CONTAINER 1 L (1/4 USGAL) below the filter to collect the 
R  unwanted hydraulic fluid. 
R  4. Procedure_________ 
R  (Ref. Fig. 301/TASK 29-13-44-991-001) 
R  Subtask 29-13-44-020-051 
R  A. Removal of the Clogging Indicator 
R  (1) Loosen and remove the clogging indicator (5) from the filter head 
R  (1). 
R  (2) Remove and discard the packings (7) from the clogging indicator (5).

 

R  Subtask 29-13-44-560-051 
R  B. Preparation for Installation 
R  (1) Lubricate the new packings (7) with the HYDRAULIC FLUIDS (Material 
R  No. 02-003) and install them on the clogging indicator (5). 
R  (2) Lubricate the threads of the clogging indicator (5) with the 
R  HYDRAULIC FLUIDS (Material No. 02-003). 
R  Subtask 29-13-44-420-051 
R  C. Installation of the Clogging Indicator 
R  (1) Clean the component interface and/or the adjacent area. 
R  (2) Do an inspection of the component interface and/or the adjacent area. 
R  (3) Install the new clogging indicator (5) in the filter head (1). 
R  Subtask 29-13-44-865-053 
R  D. Remove the safety clip(s) and the tag(s) and close this(these) circuit 
R  breaker(s): 
R  3801GX, 3802GX, 3803GX. 
R  Subtask 29-13-44-790-051 
R  E. Test of the Filter Assembly 
R  (1) Remove the warning notice(s). 
R  (2) Pressurize the reservoir of the Yellow hydraulic system (Ref. TASK 
R  29-14-00-614-002). 
R  (3) Pressurize the Yellow hydraulic system (Ref. TASK 29-10-00-863-002). 
R  (4) Make sure that the clogging indicator stays in. 
R  (5) Make sure that no hydraulic fluid comes out of the filter assembly. 
R  (6) Make sure that the fluid level in the reservoir of the Yellow 
R  hydraulic system is correct. Add fluid as necessary (Ref. TASK 12-12-
R  29-611-001). 
R  (7) Depressurize the Yellow hydraulic system (Ref. TASK 29-10-00-864-
R  002).

 

R  5. Close-up________ 
R  Subtask 29-13-44-860-054 
R  A. Put the aircraft back to the serviceable condition. 
R  (1) Remove the container from below the filter. 
R  (2) Connect the PTU isolation coupling (Ref. TASK 29-23-00-860-002). 
R  (3) Make sure that the work area is clean and clear of tool(s) and other 
R  items. 
R  Subtask 29-13-44-410-051 
R  B. Close Access 
R  (1) Close the access panel 196BB.

 

 FILTER HP (3048GM) - SERVICING
______________________________
 TASK 29-13-45-610-001
 Servicing of the HP-Filter (3048GM)
 WARNING : MAKE SURE THAT THE GROUND SAFETY-LOCKS ARE IN POSITION ON THE LANDING
_______
 GEAR.

 WARNING : MAKE SURE THAT THE TRAVEL RANGES OF THE FLIGHT CONTROL SURFACES ARE
_______
 CLEAR BEFORE YOU PRESSURIZE/DEPRESSURIZE A HYDRAULIC SYSTEM.

 1. Reason for the Job
__________________
 -Replace the filter element.
 2. Job Set-up Information
______________________
 A. Fixtures, Tools, Test and Support Equipment
 -------------------------------------------------------------------------------
REFERENCE  QTY DESIGNATION
 -------------------------------------------------------------------------------
No specific circuit breaker(s) safety clip(s)
 No specific hydraulic ground supply
 No specific warning notices
 No specific container 3.0 l (0.7925 USgal)

 B. Consumable Materials
 -------------------------------------------------------------------------------
REFERENCE  DESIGNATION
 -------------------------------------------------------------------------------
No specific  lockwire 0.8 mm (0.032 in.)
R  Material No. 02-003 F NSA 307110 TYPE 4 HYDRAULIC FLUID (PHOSPHATE ESTER BASE) (Ref. 20-31-00)
 C. Expendable Parts
 -------------------------------------------------------------------------------
FIG.ITEM |DESIGNATION  |IPC-CSN
 -------------------------------------------------------------------------------
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM HYDRAULIC POWER 液压4(56)