R (1) Open the access panel 196BB.
R Subtask 29-13-45-860-053
R D. Aircraft Maintenance Configuration
R WARNING : OBEY THE HYDRAULIC SAFETY PROCEDURES._______
R (1) Obey the hydraulic safety procedures (Ref. TASK 29-00-00-910-002).
R (2) Make sure that the Yellow hydraulic system is depressurized and put
R it in the maintenance configuration.
R (Ref. TASK 29-00-00-864-001).
R (3) Depressurize the reservoir of the Yellow hydraulic system (Ref. TASK
R 29-14-00-614-001).
R (4) Disconnect the isolation coupling of the Power Transfer Unit (PTU)
R (Ref. TASK 29-23-00-860-001).
R (5) Put the CONTAINER 1 L (1/4 USGAL) below the filter to collect the
R unwanted hydraulic fluid.
R 4. Procedure_________
R Subtask 29-13-45-020-051
R A. Removal of the Clogging Indicator
R (1) Loosen and remove the clogging indicator (4) from the filter head
R (1).
R (2) Remove and discard the packings (7) from the clogging indicator (4).
R (3) Remove and retain the ring (6) from the clogging indicator (4).
R Subtask 29-13-45-560-051
R B. Preparation for Installation
R (1) Put the ring (6) on the clogging indicator (4).
R (2) Lubricate the new packings (7) with the HYDRAULIC FLUIDS (Material
R No. 02-003) and install them on the clogging indicator (4).
R (3) Lubricate the threads of the clogging indicator (4) with the
R HYDRAULIC FLUIDS (Material No. 02-003).
R Subtask 29-13-45-420-051
R C. Installation of the Clogging Indicator
R (1) Clean the component interface and/or the adjacent area.
R (2) Do an inspection of the component interface and/or the adjacent area.
R (3) Install the new clogging indicator (4) in the filter head (1).
R Subtask 29-13-45-942-052
R D. Safety Precautions
R (1) Remove the warning notice(s).
R Subtask 29-13-45-865-053
R E. Remove the safety clip(s) and the tag(s) and close this(these) circuit
R breaker(s):
R 3801GX, 3802GX, 3803GX.
R Subtask 29-13-45-790-051
R F. Test of the Filter Assembly
R (1) Pressurize the reservoir of the Yellow hydraulic system (Ref. TASK
R 29-14-00-614-002).
R (2) Pressurize the Yellow hydraulic system (Ref. TASK 29-10-00-863-002).
R (3) Make sure that the clogging indicator stays in.
R (4) Make sure that no hydraulic fluid comes out of the filter assembly.
R (5) Depressurize the Yellow hydraulic system (Ref. TASK 29-10-00-864-
R 002).
R 5. Close-up________
R Subtask 29-13-45-860-054
R A. Put the aircraft back to the serviceable condition.
R (1) Make sure that the fluid level in the Yellow reservoir is correct.
R Add fluid as necessary (Ref. TASK 12-12-29-611-001).
R (2) Remove the container from below the filter.
R (3) Connect the PTU isolation coupling (Ref. TASK 29-23-00-860-002).
R (4) Make sure that the work area is clean and clear of tool(s) and other
R items.
R Subtask 29-13-45-410-051
R B. Close Access
R (1) Close the access panel 196BB.
SLIDE - COMPENSATED (3010GM) - REMOVAL/INSTALLATION
___________________________________________________
TASK 29-13-47-000-001
Removal of the Compensated Slide (3010GM)
WARNING : PUT THE SAFETY DEVICES AND THE WARNING NOTICES IN POSITION BEFORE YOU
_______ START A TASK ON OR NEAR:
-
THE FLIGHT CONTROLS
-
THE FLIGHT CONTROL SURFACES
-
THE LANDING GEAR AND THE RELATED DOORS
-COMPONENTS THAT MOVE.
WARNING : MAKE SURE THAT THE GROUND SAFETY-LOCKS ARE IN POSITION ON THE LANDING
_______ GEAR.
1. Reason for the Job
__________________
Self Explanatory