• 热门标签

当前位置: 主页 > 航空资料 > 机务资料 >

时间:2011-04-11 09:17来源:蓝天飞行翻译 作者:航空
曝光台 注意防骗 网曝天猫店富美金盛家居专营店坑蒙拐骗欺诈消费者

 No. 3A. Flow No. 2__________GPM Flow No. 3__________GPM
 Flow No. 3A__________GPM
 NOTE: Flow No. 3A is the null leakage of the control valve for the
____
 outboard trailing edge flap.

 NOTE: Leave the ALTN FLAPS arming switch in the ARM position and
____ the flap control lever in the 10 unit detent for the remainder of hydraulic system No. 4 check.
 I. Empennage Hydraulic Control System - Internal Leakage Check
 S 866-243
 (1)  
Put the system No. 4 TAIL FLT CONTROL SHUTOFF switch in the OFF position.

 S 976-244

 (2)
Let the flow become stable for one minute and write this flow as


 flow No. 4. Flow No. 4__________GPM
 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 29-11-00
 ALL  ú ú 01 Page 666 ú Feb 10/93
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A 747-400 MAINTENANCE MANUAL
 (3)  S 976-245Subtract flow No. 4 from flow No. 3 and write this flow as flow No. 4A. Flow No. 3__________GPM Flow No. 4__________GPM Flow No. 4A__________GPM
 NOTE:____ Flow No. 4A is the null leakage for these controls: - power package for the right inboard elevator. - power package for the right outboard elevator. - control package for the lower rudder.
 (4)  S 866-246Put the system No. 4 TAIL FLT CONTROL SHUTOFF switch in the ON position.
 (5)  S 866-247Put the control column in the full forward position.
 (6)  S 976-248Let the flow become stable for one minute and write this flow as flow No. 5. Flow No. 5__________GPM
 (7)  S 866-249Put the control column in the neutral position.
 (8)  S 976-250Subtract flow No. 5 from flow No. 3 and write this flow as flow No. 5A. Flow No. 3__________GPM Flow No. 5__________GPM Flow No. 5A__________GPM
 NOTE:____ Flow No. 5A is the null leakage of the power packages for the right inboard and outboard elevators.
 (9)  S 976-251Subtract flow No. 5A from flow No. 4A and write this flow as flow No. 5B. Flow No. 4A__________GPM Flow No. 5A__________GPM Flow No. 5B__________GPM
 NOTE:____ Flow No. 5B is the null leakage for the control package of the lower rudder.

 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 29-11-00
 ALL  ú ú 01 Page 667 ú Oct 18/00
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
747-400 MAINTENANCE MANUAL
 J. Lateral Hydraulic Control System - Internal Leakage Check
 S 866-252
 (1)  
Put the system No. 4 WING FLT CONTROL SHUTOFF switch in the OFF position.

 S 976-253

 (2)
Let the flow become stable for one minute and write this flow as


 flow No. 6. Flow No. 6__________GPM
 S 976-457
 (3) Subtract flow No. 6 from flow No. 3 and write this flow as flow
 No. 6A. Flow No. 3__________GPM Flow No. 6__________GPM
 Flow No. 6A__________GPM
 NOTE: Flow No. 6A is the null leakage of these controls:
____
 -
right central-lateral control package.

 -
right inboard-aileron power package.

 -
right outboard-aileron power package.


 -internal leakage other than the null leakage of the actuators for spoilers 5 and 8.
 S 866-255
 (4)  
Put the system No. 4 WING FLT CONTROL SHUTOFF switch in the ON position.

 S 486-256

 (5)  
Install the control wheel adapter and protractor.

 S 866-458

 (6)  
Turn the control wheel 30 to 40 degrees counterclockwise.

 S 866-459

 (7)  
Put the speedbrake lever in a position 2.75-3.00 inches (7.00 cm-7.60 cm) aft of the full forward position. Measure this distance along an arc at the bottom of the lever.

 S 976-257

 (8)
Let the flow become stable for one minute and write this flow as


 flow No. 7. Flow No. 7__________GPM
 S 866-258
 (9)  
Turn the control wheel 55 to 65 degrees counterclockwise.

 (10)
 Move the speedbrake lever to the inflight detent.


 S 866-460
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:747-400 AMM 飞机维护手册 液压 HYDRAULIC 1(72)