S 086-588
(2)
If you used the system demand pump for a pressure source, remove the flowmeter:
(a)
Remove the flowmeter from the pressure line on the demand pump.
(b)
Connect the pressure line to the pressure port on the demand pump.
(c)
Put the system HYD PUMPS DEMAND switch on the P5 overhead panel in the ON position.
(d)
Examine the pressure port connection on the demand pump for leakage.
(e)
Put the system HYD PUMPS DEMAND switch in the OFF position.
(f)
Repair the cause of the leakage from the pressure connection on the demand pump.
S 086-589
(3)
If you used a hydraulic service cart for a pressure source,
disconnect the hydraulic service cart:
(a)
Disconnect the pressure line on the hydraulic service cart from the system No. 3 pressure module.
(b)
Disconnect the hydraulic service cart return line from the system No. 3 return module.
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
29-11-00
ALL ú ú 01 Page 613 ú Jun 18/01
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
747-400 MAINTENANCE MANUAL
(4) S 616-708Service the Hydraulic reservoir (AMM 12-12-01/301).
(5) S 216-590Examine the doors on the trailing edge fairing. (a) Examine the door latches on the trailing edge fairing for cracks and wear. (b) Make sure that all latch assemblies are installed. (c) Repair and adjust the latches if it is necessary (AMM 54-62-02/501).
S 416-591
CAUTION: MAKE SURE YOU LATCH THE FAIRING DOORS ON THE TRAILING EDGE
_______
CORRECTLY. DAMAGE CAN OCCUR IF THE DOORS OPEN DURING A FLIGHT.
(6) Close the fairing doors on the trailing edge (AMM 54-62-00/201).
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
29-11-00
ALL ú ú 01 Page 614 ú Oct 18/01
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
747-400
MAINTENANCE MANUAL
TASK 29-11-00-706-566
5. Hydraulic System No. 4 - Gross Internal Leakage Check
_______________________________________________
A. Standard Tools and Equipment
(1) 410DME-10AR Flowmeter (commercially available)
ACL Technologies Inc.
Santa Clara, CA 92705-5419
-
It must be able to pass a flow of 32 gpm at 3000 psig without damage.
-
It must measure a flow of 0.25 to 7.50 gpm with a precision of | 0.5% of the reading.
(2)
Hydraulic Service Cart - 0 to 3000 psi with hydraulic fluid, fire-resistant, BMS 3-11.
B.
References
(1)
AMM 24-22-00/201, Manual Control
(2)
AMM 29-11-00/201, Main Hydraulic Supply System
(3)
AMM 32-00-30/201, Landing Gear Doors
(4)
AMM 54-62-00/201, Nacelle Strut Access Panels
(5)
AMM 54-62-03/501, Trailing Edge Fairing Doors
(6)
AMM 54-62-02/501, Nacelle Strut Access Doors
C.
Access
(1)
Location Zone
484 System 4 - Strut Aft Fairing
(2)
Access Panel 484AL Trailing Edge Fairing Doors - System 4
D.
Prepare for the Hydraulic System No. 4 Gross Internal Leakage Check
S 866-567
(1) Supply electrical power (AMM 24-22-00/201).
S 496-568
WARNING: REFER TO AMM 32-00-30/201 FOR THE INSTALLATION PROCEDURE FOR
_______ LOCKS ON THE LANDING GEAR DOORS. SUDDEN MOVEMENT OF THE DOORS CAN CAUSE INJURY AND DAMAGE.
(2)
Make sure that the locks on the landing gear doors and the landing gears are installed (AMM 32-00-30/201).
S 866-569
(3)
Make sure that the person in the flight compartment can speak with the person on the ground.