No. 14A. Flow No. 13__________GPM Flow No. 14__________GPM
Flow No. 14A__________GPM
NOTE: Flow No. 14A is the null leakage of the control package
____ for the right central lateral control.
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
29-11-00
ALL ú ú 01 Page 656 ú Oct 18/00
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
747-400 MAINTENANCE MANUAL
S 086-424
(34)
Remove the control wheel adapter and the protractor.
S 866-209
(35)
Release the pressure in hydraulic system No. 3 (AMM 29-11-00/201).
S 086-210
(36)
If the system demand pump was used as a pressure source, remove the flowmeter:
(a)
Remove the flowmeter from the pressure line on the demand pump.
(b)
Connect the pressure line to the pressure port on the demand pump.
(c)
Put the system HYD PUMPS DEMAND switch on the P5 overhead panel in the ON position.
(d)
Examine the pressure port connection on the demand pump for leakage.
(e)
Put the system HYD PUMPS DEMAND switch in the OFF position.
(f)
Repair the cause of the leakage from the pressure connection on the demand pump.
S 086-211
(37)
If a hydraulic service cart was used a pressure source, disconnect the hydraulic service cart:
(a)
Disconnect the pressure line on the hydraulic service cart from the system No. 3 pressure module.
(b)
Disconnect the hydraulic service cart return line from the system No. 3 return module.
S 216-490
(38)
Examine the doors on the trailing edge fairing.
(a)
Examine the door latches on the trailing edge fairing for cracks and wear.
(b)
Make sure that all latch assemblies are installed.
(c)
Repair and adjust the latches if it is necessary
(AMM 54-62-03/501).
S 416-450
CAUTION: MAKE SURE YOU LATCH THE FAIRING DOORS ON THE TRAILING EDGE
_______ CORRECTLY. DAMAGE CAN OCCUR IF THE DOORS OPEN DURING A FLIGHT.
(39) Close the fairing doors on the trailing edge (AMM 54-62-00/201).
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
29-11-00
ALL ú ú 01 Page 657 ú Jun 18/01
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
747-400 MAINTENANCE MANUAL
S 096-214
WARNING: REFER TO AMM 32-00-30/201 FOR THE REMOVAL PROCEDURE FOR THE ON
_______ THE LANDING GEAR DOORS. SUDDEN MOVEMENT OF THE DOORS CAN CAUSE DAMAGE AND INJURY.
(40)
Remove the locks on the wing and body gears (AMM 32-00-30/201).
S 416-215
(41)
Close the wing and body gear doors (AMM 32-00-30/201).
S 976-451
(42)
Write the flow values on Fig. 605. Compare the measured flows to the maximum recommended flows. Replace the applicable components until the total system leakage is less than 5 GPM (or 3 GPM if the system leakage for system 3 is 5 GPM).
NOTE: If the result of a flow calculation is a negative number, it
____ is possible that the component has a null leakage of a control valve that is more than the recommended flow. Replace these components because of too much piston seal leakage.
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
29-11-00
ALL ú ú 01 Page 658 ú Oct 18/01
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
747-400
MAINTENANCE MANUAL
Record Test Flow Data:
Flow No. 1 _________________ Flow No. 8
Flow No. 2 _________________ Flow No. 9
Flow No. 3 _________________ Flow No. 10
Flow No. 4 _________________ Flow No. 11
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:747-400 AMM 飞机维护手册 液压 HYDRAULIC 1(68)