R 1EFF : 004-049, 051-099, 101-149, 151-199, 1 26-23-00Page 205 1201-299, 301-399, 401-499, 1Aug 01/05 1 1 1CES 1
Subtask 26-23-00-420-054
B. Installation of the Fire Extinguishing System Components
(1)
Install the Fire Extinguishing Bottle (Ref. TASK 26-23-41-400-004). NOTE : The Fire Extinguishing Bottle must be charged.
____
(2)
Connect all flexible hoses from the fire extinguishing bottle to the pipings.
CAUTION : APPLY A SMALL QUANTITY OF THE CORRECT GREASE TO THE MALE
_______ THREADS OF THE CONNECTIONS. THIS WILL PREVENT DAMAGE TO THE THREADS. MAKE SURE THAT GREASE DOES NOT GO INTO THE PIPES. GREASE IN THE PIPES CAN CAUSE A MALFUNCTION OF THE SYSTEM.
Subtask 26-23-00-865-071
C. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s): 1WX, 11WQ, 12WQ
Subtask 26-23-00-720-054
D. Do this functional test: (Ref. TASK 26-23-00-200-001) Subtask 26-23-00-710-054
E. Do these operational tests: (Ref. TASK 26-23-00-710-001) (Ref. TASK 26-23-00-720-001)
5. Close-up
________ **ON A/C 004-049, 051-099, 101-149, 201-299, 301-399,
Subtask 26-23-00-410-064
A. Close Access
(1)
Make sure that the work area is clean and clear of tool(s) and other items.
(2)
Install the panel 132MW.
(3)
Set the CARGO COMPT LIGHT switch 6LU to the OFF position.
R 1EFF : 004-049, 051-099, 101-149, 151-199, 1 26-23-00Page 206 1201-299, 301-399, 401-499, 1Aug 01/05 1 1 1CES 1
(4) Close the FWD cargo-compartment door 825 (Ref. TASK 52-30-00-860-002).
(5) Remove the access platform(s).
**ON A/C 151-199,
Subtask 26-23-00-410-064-A
A. Close Access
(1) Make sure that the work area is clean and clear of tool(s) and other items.
(2) Install the panel 132SW.
(3) Set the CARGO COMPT LIGHT switch 6LU to the OFF position.
(4) Close the FWD cargo-compartment door 825 (Ref. TASK 52-30-00-860-002).
(5) Remove the access platform(s).
R **ON A/C 401-499,
R Subtask 26-23-00-410-064-B
R A. Close Access
R R (1) Make sure that the work area is clean and clear of tool(s) and other items.
R (2) Install the panel 162AW.
R (3) Set the CARGO COMPT LIGHT switch 8LU to the OFF position.
R R (4) Close the AFT cargo-compartment door 826 (Ref. TASK 52-30-00-860-002).
R (5) Remove the access platform(s).
R 1EFF : 004-049, 051-099, 101-149, 151-199, 1 26-23-00Page 207 1201-299, 301-399, 401-499, 1Aug 01/05 1 1 1CES 1
R **ON A/C 004-049, 051-099, 101-149, 151-199, 201-299, 301-399, 401-499,
Subtask 26-23-00-860-053
B. Put the aircraft back to its initial configuration.
(1)
Do the EIS stop procedure
(Ref. TASK 31-60-00-860-002).
(2)
De-energize the ground service network (Ref. TASK 24-42-00-862-001).
CARGO COMPARTMENT FIRE EXTINGUISHING - DEACTIVATION/REACTIVATION
________________________________________________________________ TASK 26-23-00-040-001 Cargo Compartment DISCH LT - Verification of Fire-Extinguisher Bottle Weight
1. Reason for the Job
__________________
Refer to the MMEL TASK: 26-23-02
Fire Protection
Cargo Compartment Fire Extinguishing
"DISCH " light
2. Job Set-up Information
______________________
A. Referenced Information
中国航空网 www.aero.cn
航空翻译 www.aviation.cn