INTENTIONALLY BLANK
1 1
26-21-00Page 575 
1 1 May 01/05 1 1 1CES 1
R R  Distribution Line Figure 505/TASK 26-21-00-991-010- 12 (SHEET 1) 
 1EFF : 1 1 1CES  ALL  1 111 26-21-00 Page 576 May 01/05
R R  Distribution Line Figure 505/TASK 26-21-00-991-010- 22 (SHEET 2) 
 1EFF : 1 1 1CES  ALL  1 111 26-21-00 Page 577 May 01/05
R BOTTLE - FIRE EXTINGUISHER (1WM1,1WM2,2WM1,2WM2,5WE1,5WE2,6WE1,6WE2,7WE1,7WE2,
______________________________________________________________________________ R 8WE1,8WE2) - REMOVAL/INSTALLATION
_________________________________
 TASK 26-21-41-920-001
 Discard Cartridge
 1.
 Reason for the Job
__________________
 Refer to the MPD TASK: 262142-01
 2.
 Job Set-up Information
______________________
 A. Referenced Information
 -------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
26-21-41-000-004  Removal of the Cartridge of the Engine
 Fire-Extinguisher Bottle
 26-21-41-400-004 Installation of the Cartridge of the Engine
 Fire-Extinguisher Bottle
 3. Job Set-up
__________
 Subtask 26-21-41-860-050
 A. Not Applicable
 4. Procedure
_________
 Subtask 26-21-41-960-050
A. Remove and replace the cartridge (Ref. TASK 26-21-41-000-004) and (Ref. TASK 26-21-41-400-004).
 TASK 26-21-41-000-001 Removal of the Engine Fire-Extinguisher Bottle (6WE1,8WE1,6WE2,8WE2) WARNING : THE ACCIDENTAL FIRING OF THE EXTINGUISHER BOTTLE CAN CAUSE SERIOUS
_______
 INJURY TO PERSONS WHO WORK OR ARE IN THE CLOSE PROXIMITY.
 WARNING : IF YOU REMOVE THE FIRE EXTINGUISHER BOTTLES IN A CLOSED HANGAR, MAKE
_______
 SURE THAT THERE IS A FLOW OF NEW AIR IN THE HANGAR.
 1.
 Reason for the Job
__________________
 Self Explanatory
 2.
 Job Set-up Information
______________________
 A. Fixtures, Tools, Test and Support Equipment
 -------------------------------------------------------------------------------REFERENCE QTY DESIGNATION -------------------------------------------------------------------------------
No specific blanking caps
 No specific blanking plugs
 No specific circuit breaker(s) safety clip(s)
 No specific warning notice
 No specific access platform 1.6 m (5 ft. 3 in.)
R 263193 1 SHUNT PLUG - FIRE EXTINGUISHER CARTRIDGE R 861823 1 PROTECTIVE CAP - FIRE EXTINGUISHER CARTRIDGE
 B. Referenced Information -------------------------------------------------------------------------------
REFERENCE DESIGNATION -------------------------------------------------------------------------------26-21-41-991-001 Fig. 401 **ON A/C 001-049, 101-105, 201-210,
 26-21-41-991-002 Fig. 402 R **ON A/C 051-099, 106-149, 151-199, 211-299, 301-399, 401-499,
 26-21-41-991-002-A Fig. 402A
 **ON A/C ALL
 3. Job Set-up
__________
 Subtask 26-21-41-865-050
 A. Open, safety and tag this(these) circuit breaker(s):
 -------------------------------------------------------------------------------PANEL DESIGNATION IDENT. LOCATION -------------------------------------------------------------------------------FOR 6WE1, 6WE2
 121VU ENGINE/ENG1 AND 2 FIRE EXTIG/BTL1/SQUIB/B 2WE1 Q44
 121VU ENGINE/ENG1 AND 2 FIRE EXTIG/BTL1/SQUIB/A 1WE1 Q43
 FOR 8WE1, 8WE2 121VU ENGINE/ENG1 AND 2 FIRE EXTIG/BTL2/SQUIB/B 2WE2 Q42 121VU ENGINE/ENG1 AND 2 FIRE EXTIG/BTL2/SQUIB/A 1WE2 Q41
 Subtask 26-21-41-941-050
 B. Safety Precautions
 (1)
 On the center pedestal, on the ENG panel 115VU:
(a) Put a warning notice to tell persons not to start the engine.
 (2)
 Make sure that the engine 1(2) shutdown occurred not less than 5 minutes before you do this procedure.
 (3)
 On the overhead maintenance panel 50VU:
 (a)
 Make sure that the ON legend of the ENG/FADEC GND PWR/1(2) pushbutton switch is off.
 (b)
 Put a warning notice to tell persons not to energize the FADEC 1(2).
 (4) Put the access platform in position below the pylon.
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM FIRE PROTECTION 防火2(29)