 On the FUEL page of the ECAM lower display unit: - the APU LP fuel-valve symbol is shown in the closed position.
 22. On the external power control panel 108VU: 

R 1EFF : 001-049, 063-099, 101-149, 151-199, 1 26-22-00Page 511 1201-299, 301-399, 401-499, 1Aug 01/05 1 1 1CES 1


 -------------------------------------------------------------------------------
ACTION RESULT -------------------------------------------------------------------------------
-release the APU SHUT OFF pushbutton switch and close guard.
 23. On the overhead panel 25VU:
-release the APU MASTER SW pushbutton switch.
24. On the glareshield panel 130VU or 131VU:
-push the MASTER CAUT
pushbutton switch.

 25. On the overhead panel 25VU:
-push the APU MASTER SW twice (on/off) to reset the ECB (59KD).
26. On the overhead panel 25VU:
-push the pushbutton APU MASTER SW to the ON position.
27. On the APU FIRE panel 20VU:
-lift the guard and release the APU FIRE pushbutton switch.
On the overhead panel 25VU:
-
the FAULT legend in the APU MASTER SWpushbutton switch goes off.

 -
the ON legend in the APU MASTER SW pushbutton switch goes off.

 On the ECAM upper display unit:

 -
the warning, MASTER SW .... OFF goes off.

On the glareshield panels 130VU and131VU:

-
the MASTER CAUT lights go off.

On the ECAM upper display unit:

-
the warning,APU EMER SHUT DOWNgoes off.

On the overhead panel 25VU:

-
the ON legend in the pushbutton APUMASTER SW comes on.

 On the FUEL page of the ECAM lower display unit:

 -
the APU LP fuel-valve symbol is shown in the open position.

On the APU FIRE panel 20VU:

-
the SQUIB legend in the AGENTpushbutton switch comes on.

 On the ECAM upper display unit:

 -
the warning, APU EMER SHUT DOWN MASTER SW .... OFF comes on.


R 1EFF : 001-049, 063-099, 101-149, 151-199, 1 26-22-00Page 512 1201-299, 301-399, 401-499, 1Aug 01/05 1 1 1CES 1


 -------------------------------------------------------------------------------
ACTION RESULT -------------------------------------------------------------------------------
28. On the APU FIRE panel 20VU:
-push the APU FIRE pushbutton switch and close the guard.
29. On the overhead panel 25VU:
-release the APU MASTER SW pushbutton switch.
30. On the glareshield panel 130VU or 131VU:
-push the MASTER CAUT pushbutton switch.
 31. On the overhead panel 25VU:
-push the APU MASTER SW twice (on/off) to reset the ECB (59KD).
On the glareshield panels 130VU and 131VU:
 -the MASTER CAUT lights come on,
 -a single chime is heard.
 On the overhead panel 25VU:
 -
the FAULT legend in the pushbutton APU MASTER SW comes on.

 On the FUEL page of the ECAM lower display unit:

 -
the APU LP fuel-valve symbol is shown in the closed position.

On the APU FIRE panel 20VU:

-
the SQUIB legend in the AGENTpushbutton switch goes off.

On the overhead panel 25VU:

-
the FAULT legend in the APU MASTER SWpushbutton switch goes off.

 -
the ON legend in the APU MASTER SW pushbutton switch goes off.

 On the ECAM upper display unit:

 -
the warning, MASTER SW .... OFF goes off.

On the glareshield panels 130VU and131VU:

-
the MASTER CAUT lights go off.

On the ECAM upper display unit:

-
the warning,APU EMER SHUT DOWNgoes off.

 On the overhead panel 25VU:

 -
the FAULT legend in the APU MASTER SW pushbutton switch goes off.


R 1EFF : 001-049, 063-099, 101-149, 151-199, 1 26-22-00Page 513 1201-299, 301-399, 401-499, 1Aug 01/05 1 1 1CES 1


R **ON A/C 051-062,


R Subtask 26-22-00-710-053-A
R A. Test
R -------------------------------------------------------------------------------R ACTION RESULT R -------------------------------------------------------------------------------
R 1. In the INT LT section of the
R overhead panel 25VU:
R - put the ANN LT switch in the
R TEST position.

R 2. In the INT LT section of the
R overhead panel 25VU:
R - put the ANN LT switch in the
R BRT position.

R 3. On the circuit breaker panel
R 121VU:
R - open the circuit breaker
R APU/FUEL/LP VALVE/CTL 1QF.

R 4. On the overhead panel 25VU:
R - push the APU MASTER SW
R pushbutton switch to the ON
R position.

R 5. On the ECAM control panel:
R - push the FUEL pushbutton.

R
R
R
R

R 6. In the APU/AUTO EXTING section of
 
中国航空网 www.aero.cn