R 1EFF : 001-049, 063-099, 101-149, 151-199, 1 26-22-00Page 511 1201-299, 301-399, 401-499, 1Aug 01/05 1 1 1CES 1
 -------------------------------------------------------------------------------
ACTION RESULT -------------------------------------------------------------------------------
-release the APU SHUT OFF pushbutton switch and close guard.
 23. On the overhead panel 25VU: 
-release the APU MASTER SW pushbutton switch. 
24. On the glareshield panel 130VU or 131VU: 
-push the MASTER CAUT 
pushbutton switch.
 25. On the overhead panel 25VU: 
-push the APU MASTER SW twice (on/off) to reset the ECB (59KD). 
26. On the overhead panel 25VU: 
-push the pushbutton APU MASTER SW to the ON position. 
27. On the APU FIRE panel 20VU: 
-lift the guard and release the APU FIRE pushbutton switch. 
On the overhead panel 25VU:
-
the FAULT legend in the APU MASTER SWpushbutton switch goes off.
 -
the ON legend in the APU MASTER SW pushbutton switch goes off.
On the ECAM upper display unit:
 -
the warning, MASTER SW .... OFF goes off.
On the glareshield panels 130VU and131VU:
-
the MASTER CAUT lights go off.
On the ECAM upper display unit:
-
the warning,APU EMER SHUT DOWNgoes off.
On the overhead panel 25VU:
-
the ON legend in the pushbutton APUMASTER SW comes on.
On the FUEL page of the ECAM lower display unit:
 -
the APU LP fuel-valve symbol is shown in the open position.
On the APU FIRE panel 20VU:
-
the SQUIB legend in the AGENTpushbutton switch comes on.
On the ECAM upper display unit:
 -
the warning, APU EMER SHUT DOWN MASTER SW .... OFF comes on.
R 1EFF : 001-049, 063-099, 101-149, 151-199, 1 26-22-00Page 512 1201-299, 301-399, 401-499, 1Aug 01/05 1 1 1CES 1
 -------------------------------------------------------------------------------
ACTION RESULT -------------------------------------------------------------------------------
28. On the APU FIRE panel 20VU: 
-push the APU FIRE pushbutton switch and close the guard. 
29. On the overhead panel 25VU: 
-release the APU MASTER SW pushbutton switch. 
30. On the glareshield panel 130VU or 131VU: 
-push the MASTER CAUT pushbutton switch.
 31. On the overhead panel 25VU: 
-push the APU MASTER SW twice (on/off) to reset the ECB (59KD). 
On the glareshield panels 130VU and 131VU:
 -the MASTER CAUT lights come on,
 -a single chime is heard.
 On the overhead panel 25VU:
 -
the FAULT legend in the pushbutton APU MASTER SW comes on.
On the FUEL page of the ECAM lower display unit:
 -
the APU LP fuel-valve symbol is shown in the closed position.
On the APU FIRE panel 20VU:
-
the SQUIB legend in the AGENTpushbutton switch goes off.
On the overhead panel 25VU:
-
the FAULT legend in the APU MASTER SWpushbutton switch goes off.
 -
the ON legend in the APU MASTER SW pushbutton switch goes off.
On the ECAM upper display unit:
 -
the warning, MASTER SW .... OFF goes off.
On the glareshield panels 130VU and131VU:
-
the MASTER CAUT lights go off.
On the ECAM upper display unit:
-
the warning,APU EMER SHUT DOWNgoes off.
On the overhead panel 25VU:
 -
the FAULT legend in the APU MASTER SW pushbutton switch goes off.
R 1EFF : 001-049, 063-099, 101-149, 151-199, 1 26-22-00Page 513 1201-299, 301-399, 401-499, 1Aug 01/05 1 1 1CES 1
R **ON A/C 051-062,
R Subtask 26-22-00-710-053-A 
R A. Test 
R -------------------------------------------------------------------------------R ACTION RESULT R -------------------------------------------------------------------------------
R 1. In the INT LT section of the 
R overhead panel 25VU: 
R - put the ANN LT switch in the 
R TEST position.
R 2. In the INT LT section of the 
R overhead panel 25VU: 
R - put the ANN LT switch in the 
R BRT position.
R 3. On the circuit breaker panel 
R 121VU: 
R - open the circuit breaker 
R APU/FUEL/LP VALVE/CTL 1QF.
R 4. On the overhead panel 25VU: 
R - push the APU MASTER SW 
R pushbutton switch to the ON 
R position.
R 5. On the ECAM control panel: 
R - push the FUEL pushbutton.
R 
R 
R 
R
R 6. In the APU/AUTO EXTING section of 中国航空网 www.aero.cn 航空翻译 www.aviation.cn 本文链接地址:A320飞机维护手册 AMM FIRE PROTECTION 防火2(64)