R TASK 26-22-00-040-010
R  To make sure that the APU Automatic Fire Extinguishing System is operative when  
R  the APU FIRE Light on External Power Panel is inoperative  
R  1. Reason for the Job__________________  
R  Refer to the MMEL TASK: 26-22-11  
R  APU Fire Extinguishing  
R  APU Fire Light on External  
R  Power Panel  
R  2. Job Set-up Information______________________  
R  Not Applicable  
R  3. Job Set-up__________  
R  Subtask 26-22-00-860-068  
R  A. Aircraft Maintenance Configuration  
R  (1) There is no special job set-up for this task.  
R  4. Procedure_________  
R  Subtask 26-22-00-710-074  
R  A. Operational Test of the Test Circuit  
R  ------------------------------------------------------------------------------- 
R  ACTION  RESULT  
R  ------------------------------------------------------------------------------- 
R  1. On ground:  On the External Power Panel 108 VU:  
R  - the red APU FIRE light comes on.  
R  - the external warning horn sounds.  
R  NOTE : The APU fire extinguisher____  
R  operates automatically three  
R  seconds after the fire warning.  
R  2. On ground:  On the External Power Panel 108 VU:  
R  - the red APU FIRE light goes off.  
R  NOTE : The APU FIRE light goes off if____  
R  the fire is extinguished.
R 5. Close-up
________
R Subtask 26-22-00-860-069 
R A. Make sure that the work area is clean and clear of tool(s) and other R items.
R TASK 26-22-00-040-011
R  To make sure that the APU Automatic Fire Extinguishing System is operative when  
R  the APU SHUT OFF PB on External Power Panel is inoperative  
R  1. Reason for the Job__________________  
R  Refer to the MMEL TASK: 26-22-12  
R  APU Fire Extinguishing  
R  APU Shut Off pb on External  
R  Power Panel  
R  2. Job Set-up Information______________________  
R  A. Referenced Information  
R  ------------------------------------------------------------------------------- 
R  REFERENCE  DESIGNATION  
R  ------------------------------------------------------------------------------- 
R  24-41-00-862-002  De-energize the Aircraft Electrical Circuits Supplied  
R  from the External Power  
R  3. Job Set-up__________  
R  Subtask 26-22-00-860-070  
R  A. Aircraft Maintenance Configuration  
R  (1) There is no special job set-up for this task.
R 4. Procedure
_________
R  Subtask 26-22-00-710-075  
R  A. Operational Test of the Test Circuit  
R  ------------------------------------------------------------------------------- 
R  ACTION  RESULT  
R  -------------------------------------------------------------------------------
R  1. On the External Power Panel 108  On the External Power Panel 108 VU:  
R  VU:  - the warning horn goes off.  
R  - lift the guard then push and  
R  release the APU SHUT OFF  
R  pushbutton switch.  
R  2. On ground:  
R  NOTE : If an APU fire occurs and____  
R  someone outside the  
R  aircraft pushs the APU  
R  SHUT OFF pushbutton it  
R  makes sure, that the APU  
R  has shut down  
R  automatically.  
R  5. Close-up________  
R  Subtask 26-22-00-860-071 
R  A. Put the aircraft back to its initial configuration.  
R  (1) Make sure that the work area is clean and clear of tool(s) and other  
R  items.  
R  (Ref. TASK 24-41-00-862-002).
 TASK 26-22-00-040-012
 Test Circuit Verification  
R R  WARNING : MAKE SURE THAT ALL THE CIRCUITS IN MAINTENANCE ARE ISOLATED BEFORE_______ YOU SUPPLY ELECTRICAL POWER TO THE AIRCRAFT.  
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM FIRE PROTECTION 防火2(58)