-the OK legend in the TEST pushbutton switch comes on.
NOTE : If the OK legend in the TESTpushbutton switch comes on, all components operate correctly.
In the APU/AUTO EXTING section of panel 50 VU:
-the test circuit sets back.
R A. Put the aircraft back to its initial configuration.
R (1) De-energize the aircraft electrical circuits R (Ref. TASK 24-41-00-862-002).

R TASK 26-22-00-040-010


R  To make sure that the APU Automatic Fire Extinguishing System is operative when 
R  the APU FIRE Light on External Power Panel is inoperative 
R  1. Reason for the Job__________________ 
R  Refer to the MMEL TASK: 26-22-11 
R  APU Fire Extinguishing 
R  APU Fire Light on External 
R  Power Panel 
R  2. Job Set-up Information______________________ 
R  Not Applicable 
R  3. Job Set-up__________ 
R  Subtask 26-22-00-860-068 
R  A. Aircraft Maintenance Configuration 
R  (1) There is no special job set-up for this task. 
R  4. Procedure_________ 
R  Subtask 26-22-00-710-074 
R  A. Operational Test of the Test Circuit 
R  -------------------------------------------------------------------------------
R  ACTION  RESULT 
R  -------------------------------------------------------------------------------
R  1. On ground:  On the External Power Panel 108 VU: 
R  - the red APU FIRE light comes on. 
R  - the external warning horn sounds. 
R  NOTE : The APU fire extinguisher____ 
R  operates automatically three 
R  seconds after the fire warning. 
R  2. On ground:  On the External Power Panel 108 VU: 
R  - the red APU FIRE light goes off. 
R  NOTE : The APU FIRE light goes off if____ 
R  the fire is extinguished.


R 5. Close-up
________

R Subtask 26-22-00-860-069
R A. Make sure that the work area is clean and clear of tool(s) and other R items.

R TASK 26-22-00-040-011


R  To make sure that the APU Automatic Fire Extinguishing System is operative when 
R  the APU SHUT OFF PB on External Power Panel is inoperative 
R  1. Reason for the Job__________________ 
R  Refer to the MMEL TASK: 26-22-12 
R  APU Fire Extinguishing 
R  APU Shut Off pb on External 
R  Power Panel 
R  2. Job Set-up Information______________________ 
R  A. Referenced Information 
R  -------------------------------------------------------------------------------
R  REFERENCE  DESIGNATION 
R  -------------------------------------------------------------------------------
R  24-41-00-862-002  De-energize the Aircraft Electrical Circuits Supplied 
R  from the External Power 
R  3. Job Set-up__________ 
R  Subtask 26-22-00-860-070 
R  A. Aircraft Maintenance Configuration 
R  (1) There is no special job set-up for this task.


R 4. Procedure
_________

R  Subtask 26-22-00-710-075 
R  A. Operational Test of the Test Circuit 
R  -------------------------------------------------------------------------------
R  ACTION  RESULT 
R  -------------------------------------------------------------------------------

R  1. On the External Power Panel 108  On the External Power Panel 108 VU: 
R  VU:  - the warning horn goes off. 
R  - lift the guard then push and 
R  release the APU SHUT OFF 
R  pushbutton switch. 
R  2. On ground: 
R  NOTE : If an APU fire occurs and____ 
R  someone outside the 
R  aircraft pushs the APU 
R  SHUT OFF pushbutton it 
R  makes sure, that the APU 
R  has shut down 
R  automatically. 
R  5. Close-up________ 
R  Subtask 26-22-00-860-071 

R  A. Put the aircraft back to its initial configuration. 
R  (1) Make sure that the work area is clean and clear of tool(s) and other 
R  items. 
R  (Ref. TASK 24-41-00-862-002).


 TASK 26-22-00-040-012


 Test Circuit Verification 
R R  WARNING : MAKE SURE THAT ALL THE CIRCUITS IN MAINTENANCE ARE ISOLATED BEFORE_______ YOU SUPPLY ELECTRICAL POWER TO THE AIRCRAFT. 
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM FIRE PROTECTION 防火2(58)