121VU APU/FIRE AND OVHT/DET/LOOP B  2WG  L44
 121VU APU/FIRE AND OVHT/DET/LOOP A  1WG  L43
 121VU APU/ECB/SPLY  1KD  L41
 121VU APU/FIRE/EXTIG/SQUIB/B  2WF  L39
 121VU APU/FIRE/EXTIG/SQUIB/A  1WF  L38
 121VU APU/FIRE/LP VALVE/NORM  4WF  M42
 121VU APU/FIRE/LP VALVE/STBY  3WF  M41
 4. Procedure_________
 Subtask 26-22-00-710-052
 A. Test

 -------------------------------------------------------------------------------ACTION RESULT -------------------------------------------------------------------------------
1. On the circuit breaker panel 121VU: 
R R  - open the circuit breaker AUTO EXTING GND TEST 30WF (L40)
 2. On the APU FIRE panel 20VU: - push and hold the APU FIRE/TEST pushbutton switch. 

On the APU FIRE panel 20VU:
-
the APU FIRE light in the APU FIREpushbutton switch comes on,

 -
the DISCH and SQUIB legends in the AGENT pushbutton switch come on.

 On the glareshield panels 130VU and 131VU:

 -
the MASTER WARN lights flash,


 -a continuous repetitive chime is heard.
 On the ECAM upper display unit:
 -the warning, APU FIRE APU FIRE P/B....PUSH AGENT....DISCH


 -------------------------------------------------------------------------------
ACTION RESULT -------------------------------------------------------------------------------
3. On the APU FIRE panel 20VU:
-release the APU FIRE/TEST pushbutton switch.
R
4. On the circuit breaker panel 121VU:
 -close the circuit breaker AUTO EXTING GND TEST 30WF (L40).
 5. Close-up
________
 Subtask 26-22-00-860-051 comes on.
On the APU FIRE panel 20VU:
-
the APU FIRE light in the APU FIREpushbutton switch goes off,

 -
the DISCH and SQUIB legends in the AGENT pushbutton switch go off.

 On the glareshield panels 130VU and 131VU:

 -
the MASTER WARN lights go off,

 -
the continuous repetitive chime stops.

 On the ECAM upper display unit:

 -
the warning, APU FIRE APU FIRE P/B....PUSH AGENT....DISCH goes off.


 A. Put the aircraft back to its initial configuration.
 (1)
 Do the EIS stop procedure
 (Ref. TASK 31-60-00-860-002).


 (2)
 De-energize the aircraft electrical circuits (Ref. TASK 24-41-00-862-002).

 

 TASK 26-22-00-710-002


 Operational Test of APU Auto-Fire-Exting. Circuit and the APU LP Fuel-Valve operation using each indiv. motor in turn and Test APU Emerg. Shutdown Circuit
 WARNING : THE ACCIDENTAL FIRING OF THE EXTINGUISHER BOTTLE CAN CAUSE SERIOUS
_______ INJURY TO PERSONS WHO WORK OR ARE IN THE CLOSE PROXIMITY.
 1.
 Reason for the Job

__________________
 Refer to the MPD TASK: 262200-02


 2.
 Job Set-up Information


______________________
 A. Fixtures, Tools, Test and Support Equipment
 -------------------------------------------------------------------------------REFERENCE QTY DESIGNATION -------------------------------------------------------------------------------
No specific circuit breaker(s) safety clip(s)
 B. Referenced Information
 -------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
24-41-00-861-002 Energize the Aircraft Electrical Circuits from the External Power 24-41-00-862-002 De-energize the Aircraft Electrical Circuits Supplied
 from the External Power 31-60-00-860-001 EIS Start Procedure 31-60-00-860-002 EIS Stop Procedure
 3. Job Set-up
__________ Subtask 26-22-00-860-052
 A. Aircraft Maintenance Configuration
 (1)
 Energize the aircraft electrical circuits
 (Ref. TASK 24-41-00-861-002).


 (2)
 Do the EIS start procedure (Upper ECAM DU and lower ECAM DU only) (Ref. TASK 31-60-00-860-001).

 


 Subtask 26-22-00-865-070

 B. Open, safety and tag this(these) circuit breaker(s):
 -------------------------------------------------------------------------------
PANEL DESIGNATION  IDENT. LOCATION
 -------------------------------------------------------------------------------
121VU APU/FUEL/PUMP/CTL  3QC M38
 Subtask 26-22-00-865-054
 C. Make sure that this(these) circuit breaker(s) is(are) closed:
 -------------------------------------------------------------------------------PANEL DESIGNATION IDENT. LOCATION -------------------------------------------------------------------------------121VU APU/FIRE AND OVHT/DET/LOOP B 2WG L44 121VU APU/FIRE AND OVHT/DET/LOOP A 1WG L43 121VU APU/APU/CTL 2KD L42 121VU APU/ECB/SPLY 1KD L41 121VU APU/AUTO/EXTIG/GND/TEST 30WF L40
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM FIRE PROTECTION 防火2(61)