____ (4), (19). This will prevent cross-connection of the cartridge electrical connectors.
(3)
Remove the nut (22), the bolt (23) and disconnect the link (24).
(4)
Hold the bottle (1) and remove the nuts (20), the washers (21) and the bolts (28).
(5)
Remove the bottle. WARNING : BE VERY CAREFUL WHEN YOU MOVE A FILLED FIRE EXTINGUISHER
_______ BOTTLE. A HEAVY SHOCK COULD CAUSE PERCUSSION.
(a) Remove the bottle (1) and put it on an applicable support.
R 1EFF : 004-049, 051-099, 101-149, 151-199, 1 26-23-41Page 422 1201-299, 301-399, 401-499, 1Aug 01/05 1 1 1CES 1
Cargo Fire Extinguisher Bottle. Figure 402A/TASK 26-23-41-991-003-A
R 1EFF : 151-199, 401-499, 1 26-23-41Page 423 1 1 Aug 01/05 1 1 1CES 1
TASK 26-23-41-400-004
Installation of the Cargo Fire-Extinguisher Bottle (4005WX)
WARNING : THE CARTRIDGE IS AN EXPLOSIVE DEVICE. REMOVE IT BEFORE YOU
_______ DISASSEMBLE THE FIRE EXTINGUISHER BOTTLE. TO PREVENT INJURY TO THE PERSONNEL BECAUSE OF THE EXPLOSION OF THE CARTRIDGE IF IT HAS NOT BEEN FIRED:
-INSTALL A SHUNT DEVICE.
-THIS WILL SHUNT THE PINS TOGETHER ON THE CARTRIDGE BEFORE ITS
REMOVAL.
DO NOT USE A FOIL SHUNT.
WARNING : IF YOU REMOVE THE FIRE EXTINGUISHER BOTTLES IN A CLOSED HANGAR, MAKE
_______ SURE THAT THERE IS A FLOW OF NEW AIR IN THE HANGAR.
WARNING : BE VERY CAREFUL WHEN YOU MOVE A FILLED FIRE EXTINGUISHER BOTTLE. A
_______ HEAVY SHOCK COULD CAUSE PERCUSSION.
1. Reason for the Job
__________________
Self Explanatory
2. Job Set-up Information
______________________
A. Fixtures, Tools, Test and Support Equipment
-------------------------------------------------------------------------------REFERENCE QTY DESIGNATION
-------------------------------------------------------------------------------
No specific access platform 1.9 m (6 ft. 3 in.)
No specific Torque Wrench : range 1.00 to 10.00 m.daN
(8.00 to 75.00 lbf.ft)
B. Consumable Materials
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
No specific corrosion resistant steel lockwire dia. 0.8 mm
(0.030 in)
R 1EFF : 004-049, 051-099, 101-149, 151-199, 1 26-23-41Page 424 1201-299, 301-399, 401-499, 1Aug 01/05 1 1 1CES 1
C. Expendable Parts
-------------------------------------------------------------------------------
FIG.ITEM |DESIGNATION |IPC-CSN
-------------------------------------------------------------------------------
29 lock washer 26-23-02 02D-100 29 lock washer 26-23-02 02E-100 29 lock washer 26-23-02 02F-100
D. Referenced Information
-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------
24-42-00-861-001 Energize the Ground Service Network from the External Power 24-42-00-862-001 De-energize the Ground Service Network Supplied from the External Power 26-16-00-710-001 Operational Check of Cargo-Compartment Smoke-Detection by PTT 26-23-00-200-005 Restoration of the Fire Extinguishing System after Activation 26-23-41-000-005 Removal of the Cartridge of the Cargo Fire-Extinguisher Bottle 26-23-41-400-005 Installation of the Cartridge of the Cargo Fire-Extinguisher Bottle 52-30-00-860-001 Open the FWD or AFT Cargo-Compartment Door with the Yellow Electric Pump 52-30-00-860-002 Close the FWD or AFT Cargo-Compartment Door with the Yellow Electric Pump
**ON A/C 004-049, 051-099, 101-149, 201-299, 301-399,
26-23-41-991-003 Fig. 402
R **ON A/C 151-199, 401-499,
26-23-41-991-003-A Fig. 402A
R 1EFF : 004-049, 051-099, 101-149, 151-199, 1 26-23-41Page 425 1201-299, 301-399, 401-499, 1Aug 01/05 1 1 1CES 1R **ON A/C 004-049, 051-099, 101-149, 151-199, 201-299, 301-399, 401-499,
3. Job Set-up
__________
Subtask 26-23-41-941-059
A. Aircraft Maintenance Configuration
(1) If the installation of the bottle is done after a discharge of the fire extinguishing agent:
-do the restoration of the fire extinguishing system after activation (Ref. TASK 26-23-00-200-005) at the same time.
Subtask 26-23-41-860-050
B. Aircraft Maintenance Configuration
(1)
Make sure that the access platform is in position at the zone 825.
(2)
Make sure that the ground service network is energized (Ref. TASK 24-42-00-861-001).
**ON A/C 004-049, 051-099, 101-149, 201-299, 301-399,
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM FIRE PROTECTION 防火2(106)