 On the ECAM upper display unit: - the warning, MASTER SW .... OFF
 goes off.
 15. On the glareshield panel 130VU or 131VU:  On the glareshield panels 130VU and131VU:
 - push the MASTER CAUT pushbutton switch. - the MASTER CAUT lights go off.
 16. On the overhead panel 25VU:  On the ECAM upper display unit: 

R 1EFF : 001-049, 063-099, 101-149, 151-199, 1 26-22-00Page 535 1201-299, 301-399, 401-499, 1Aug 01/05 1 1 1CES 1


 -------------------------------------------------------------------------------
ACTION RESULT -------------------------------------------------------------------------------
-push the APU MASTER SW twice  - the warning,
 (on/off) to reset the ECB APU EMER SHUT DOWN
 (59KD). goes off.

 On the overhead panel 25VU:
 -the FAULT legend in the APU MASTER SW pushbutton switch goes off.
 17. On the circuit breaker panel 121VU:
 -close the circuit breaker
 APU/FIRE/LP VALVE/NORM 4WF.

 Subtask 26-22-00-710-058-B
 B. APU LP Fuel-Valve dual Actuator Test.
 -------------------------------------------------------------------------------ACTION RESULT -------------------------------------------------------------------------------
1. In the INT LT section of the  In the cockpit:
 overhead panel 25VU:  - all annunciator lights come on fully
 - put the ANN LT switch in the  bright.
 TEST position.
 2. In the INT LT section of the  In the cockpit:
 overhead panel 25VU:  - all applicable annunciator lights go
 - put the ANN LT switch in the  off.
 BRT position.
 3. On the circuit breaker panel
 121VU:
 - open the circuit breaker
 APU/FUEL/LP VALVE/CTL 1QF.
 4. On the overhead panel 25VU:  On the overhead panel 25VU:
 - push the APU MASTER SW  - the ON legend in the APU MASTER SW
 pushbutton switch.  pushbutton switch comes on.
 5. On the ECAM control panel:  On the ECAM lower display unit:
 - push the FUEL pushbutton  - the FUEL system page comes into view,
 switch.  - the APU LP fuel-valve symbol is shown
 in the open position. 

R 1EFF : 001-049, 063-099, 101-149, 151-199, 1 26-22-00Page 536 1201-299, 301-399, 401-499, 1Aug 01/05 1 1 1CES 1


 -------------------------------------------------------------------------------
ACTION RESULT -------------------------------------------------------------------------------
6. On the APU FIRE panel 20VU:
-lift the guard and release the APU FIRE pushbutton switch.
7. On the APU FIRE panel 20VU:
-push the APU FIRE pushbutton switch and close the guard.
8. On the overhead panel 25VU:
-release the APU MASTER SW
pushbutton switch.

9. On the glareshield panel 130VU or 131VU:
-push the MASTER CAUT pushbutton switch.
On the APU FIRE panel 20VU:
-
the SQUIB legend in the AGENTpushbutton switch comes on.

 On the ECAM upper display unit:

 -
the warning, APU EMER SHUT DOWN MASTER SW .... OFF comes on.

 On the glareshield panels 130VU and 131VU:

 -
the MASTER CAUT lights come on,


 -a single chime is heard.
 On the overhead panel 25VU:
 -
the FAULT legend in the pushbutton APU MASTER SW comes on.

 On the FUEL page of the ECAM lower display unit:

 -
the APU LP fuel-valve symbol is shown in the closed position.

On the APU FIRE panel 20VU:

-
the SQUIB legend in the AGENTpushbutton switch goes off.

On the overhead panel 25VU:

-
the FAULT legend in the APU MASTER SWpushbutton switch goes off.

 -
the ON legend in the APU MASTER SW pushbutton switch goes off.

 On the ECAM upper display unit:

 -
the warning, MASTER SW .... OFF goes off.

On the glareshield panels 130VU and131VU:

-
the MASTER CAUT lights go off.


R 1EFF : 001-049, 063-099, 101-149, 151-199, 1 26-22-00Page 537 1201-299, 301-399, 401-499, 1Aug 01/05 1 1 1CES 1


 -------------------------------------------------------------------------------
ACTION RESULT -------------------------------------------------------------------------------
10. On the overhead panel 25VU:
-push the APU MASTER SW twice (on/off) to reset the ECB (59KD).
11. On the circuit breaker panel 121VU:
 -close the circuit breaker APU/FUEL/LP VALVE/CTL 1QF,
 - open the circuit breaker APU/FUEL/LP VALVE/SPLY 2QF.
 12. On the overhead panel 25VU:
-push the APU MASTER SW
 