1.
Reason for the Job
__________________
Self Explanatory
2.
Job Set-up Information
______________________
A. Fixtures, Tools, Test and Support Equipment
-------------------------------------------------------------------------------
REFERENCE QTY DESIGNATION
-------------------------------------------------------------------------------
No specific 1 SCALE 10 KG (22 LB), ACCURACY 0.001 KG (0.0022 LB)
B. Referenced Information
-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------
24-42-00-861-001 Energize the Ground Service Network from the External Power
24-42-00-862-001 De-energize the Ground Service Network Supplied from the External Power
R **ON A/C 001-049, 101-149, 151-199, 201-299,
26-24-00-991-001 Fig. 601
**ON A/C 301-399,
26-24-00-991-001-A Fig. 601A **ON A/C ALL
3. Job Set-up
__________
Subtask 26-24-00-861-050
A. Energize the ground service network
(Ref. TASK 24-42-00-861-001)
Subtask 26-24-00-010-053
B. Get Access R **ON A/C 001-049, 101-149, 151-199, 201-299,
(Ref. Fig. 601/TASK 26-24-00-991-001)
**ON A/C 301-399,
(Ref. Fig. 601A/TASK 26-24-00-991-001-A)
**ON A/C ALL
NOTE : The fire-extinguisher locations are shown with placards, which are
____ bonded on the outside of the stowage compartments, or adjacent to them.
(1)
If necessary, open the door/access panel of the stowage compartment.
(2)
Identify each fire-extinguisher and record its position.
(3)
Release/open the strap/clamp and remove each fire-extinguisher from its support bracket.
Fire-Extinguisher - Component Location
Figure 601/TASK 26-24-00-991-001
R 1EFF : 001-049, 101-149, 151-199, 201-299, 1 26-24-00Page 603 1 1 May 01/05 1 1 1CES 1
R Fire-Extinguisher - Component Location
R Figure 601A/TASK 26-24-00-991-001-A
R 1EFF : 301-399, 1 26-24-00 Page 604
1 1 Nov 01/04
1 1
1CES 1
4. Procedure
_________
Subtask 26-24-00-280-051
A. Inspection Procedure
(1)
Visual Check:
(a) Make sure that:
-
The support bracket is correctly attached and serviceable.
-
The safety device (e.g. seal wire, safety pin, safety lever) is serviceable.
-
The spray nozzle is not blocked.
-
If a FULL indicator is installed, it is in position and the seal is not broken.
-
If a gage is installed, the indicator is in the green area.
(2)
Weight Check:
R (a) Put the fire-extinguisher on a SCALE 10 KG (22 LB), ACCURACY
R 0.001 KG (0.0022 LB), and refer to the charged weight which is shown on the fire-extinguisher.
(b) Refer to the Part Number (P/N) for the related weight limits as given in the table:
===========================================================================
P/N Weight Limits (Initial Charged weight)
============================================================================
H1-10AIR (TYPE H1-10) -20.0 g +20.0 g (-0.70 oz +0.70 oz)
----------------------------------------------------------------------------
74-00 -2% +2%
74-20
----------------------------------------------------------------------------
BA21741SR-2 -10.0 g +10.0 g (-0.35 oz +0.35 oz)
BA51015-3
BA5101%R-3
----------------------------------------------------------------------------
898052 (MODEL XL2.5HZ) -95%
----------------------------------------------------------------------------
892480 -0.0 g +0.0 g (-0.0 oz +0.0 oz)
100-9750 (MODEL HAL-035-AVH) (3) Replace the fire-extinguisher if:
-It is not in the correct condition.
-
Its weight is not in the limits.
-
Its maximum permitted life is not longer than the time to the next scheduled inspection.
5. Close-up
________ Subtask 26-24-00-410-051
A. Close Access
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM FIRE PROTECTION 防火2(111)