(0.22 and 0.28 m.daN).
(7)
At the top of the engine connect the hose (5) to the pylon tube (10).
(8)
TORQUE the hose (5) fitting to between 800 and 900 lbf.in (9.04 and
10.17 m.daN).
5. Close-up
________
Subtask 26-21-49-410-054
A. Close Access
(1)
Make sure that the work area is clean and clear of tool(s) and other items.
(2)
Close the fan cowl doors (Ref. TASK 71-13-00-410-040):
FOR 1000EM1
437AL, 438AR
FOR 1000EM2
447AL, 448AR
(3)
Remove the access platform(s).
(4)
Remove the warning notice(s).
Subtask 26-21-49-865-058
B. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s): 1WE1, 2WE1, 1WE2, 2WE2.
PIPE - ENGINE FIRE EXTINGUISHING - INSPECTION/CHECK
___________________________________________________
TASK 26-21-49-210-001 Visual Inspection of the Fan Fire Extinguishing Tube Assembly
1.
Reason for the Job
__________________
Self Explanatory
2.
Job Set-up Information
______________________
A. Fixtures, Tools, Test and Support Equipment
-------------------------------------------------------------------------------REFERENCE QTY DESIGNATION -------------------------------------------------------------------------------
No specific circuit breaker(s) safety clip(s)
No specific warning notice
No specific access platform 1 m (3 ft. 3 in.)
B. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
26-21-49-000-003 Removal of the Fire Extinguisher Tube Assembly 26-21-49-400-003 Installation of the Fire Extinguisher Tube Assembly 71-13-00-010-040 Opening of the Fan Cowl Doors 71-13-00-410-040 Closing of the Fan Cowl Doors 26-21-49-991-006 Fig. 601
3. Job Set-up
__________ Subtask 26-21-49-941-059
A. Safety Precautions
(1)
On the panel 115VU:
-put a warning notice to tell persons not to start the engine 1(2).
(2)
Make sure that the engine shutdown occurred not less than 5 minutes before you do this procedure.
(3)
On the maintenance panel 50VU:
-make sure that the ON legend of the ENG/FADEC GND PWR/1(2) pushbutton switch is off
-put a warning notice.
Subtask 26-21-49-010-062
B. Get Access
(1)
Open the fan cowl doors (Ref. TASK 71-13-00-010-040):
FOR 1000EM1
437AL, 438AR
FOR 1000EM2
447AL, 448AR
(2)
Put the access platform in position.
Subtask 26-21-49-865-061
C. Open, safety and tag this(these) circuit breaker(s):
-------------------------------------------------------------------------------PANEL DESIGNATION IDENT. LOCATION -------------------------------------------------------------------------------121VU ENGINE/ENG1 AND 2 FIRE EXTIG/BTL1/SQUIB/B 2WE1 Q44 121VU ENGINE/ENG1 AND 2 FIRE EXTIG/BTL1/SQUIB/A 1WE1 Q43 121VU ENGINE/ENG1 AND 2 FIRE EXTIG/BTL2/SQUIB/B 2WE2 Q42 121VU ENGINE/ENG1 AND 2 FIRE EXTIG/BTL2/SQUIB/A 1WE2 Q41
4. Procedure
_________
Subtask 26-21-49-210-053
A. Do a visual inspection of the Fire Extinguisher Tubes Assembly installed on the inlet cowl. (Ref. Fig. 601/TASK 26-21-49-991-006)
-------------------------------------------------------------------------------INSPECT/CHECK MAXIMUM REMARKS SERVICEABLE LIMITS -------------------------------------------------------------------------------
1. Examine the fire extinguisher tube assembly, look for:
A. Cracks, splits or kinks. None permitted. Replace the tube(Ref. TASK 26-21-49-000-003) and (Ref. TASK 26-21-49-400-003).
B. Wrinkles in bends. Maximum depth cannot be more than 3 percent of the tube diameter or 0.06 in. (1.5239 mm) which ever is smaller. If wrinkles are more thanthe allowable limits,replace the tube(Ref. TASK 26-21-49-000-003) and (Ref. TASK 26-21-49-400-003).
C. Dents. Maximum depth cannot be more than 10 percent of the tube outside diameter. Maximum radius must be less than 2 times the wall thickness. Maximum of 2 If the dents are more thanthe allowable limits,replace the tube(Ref. TASK 26-21-49-000-003) and (Ref. TASK 26-21-49-400-003).
dents for each 1 ft.
(0.30 m) of tube length.