On the lower ECAM DU:
-
the BLEED page goes out of view and the HYD page comes into view
-
the ENG 1(2) G(Y) fire valve is shown in-line and in green.
On the lower ECAM DU:
-
the HYD page goes out of view and the FUEL page comes into view
-
the ENG 1(2) LP valve is shown in-line and in green.
On the MCDU, on the LAST LEG REPORT of the AC GEN:
-
the indication CHECK FIRE HANDLE 1(2) RESET GEN 1(2) stays in view and will
1EFF : 001-049, 051-099, 101-105, 151-199, 1 26-21-00Page 565 1201-228, 301-302, 1Aug 01/05R 1 1 1CES 1
-------------------------------------------------------------------------------ACTION RESULT -------------------------------------------------------------------------------
go out of view at the subsequent flight.
17. On the MCDU: On the MCDU:
- get the SYSTEM REPORT/TEST/PNEU page (Ref. TASK 31-32-00-860-011). - the BMC 1(2) page comes into view.
18. On the MCDU: On the MCDU:
- push the line key adjacent to the CURRENT DATA indication. - the BMC 1(2)/CURRENT DATA page comesinto view
- make sure that the BIT 19 of the
LABEL 67(66) is at 0.
19. On the overhead circuit breaker On the MCDU and on the lower ECAM DU:
panel 49VU: - close the circuit breaker - there is no change.
1QG(2QG).
20. On the rear circuit breaker On the MCDU and on the lower ECAM DU:
panel 121VU: - open the circuit breaker 3QG(4QG). - there is no change.
21. On the ENG/APU fire panel 1WD: - release the ENG 1(2) FIRE pushbutton switch. On the lower ECAM DU:- the FUEL page is in view- the ENG 1(2) LP valve is shown not in-line and in amber.
R R R On the upper ECAM DU: - the ENG 1(2) SHUT DOWN warning message comes into view.
22. On the ENG/APU fire panel 1WD: - push the ENG 1(2) FIRE pushbutton switch. On the lower ECAM DU:- the ENG 1(2) LP valve is shownin-line and in green.
R R R On the upper ECAM DU: - the ENG 1(2) SHUT DOWN warning message goes out of view.
23. On the overhead circuit breaker On the lower ECAM DU:
panel 49VU: - there is no change.
-------------------------------------------------------------------------------ACTION RESULT -------------------------------------------------------------------------------
- open the circuit breaker
1QG(2QG).
24. On the ENG/APU fire panel 1WD:
- release the ENG 1(2) FIRE
pushbutton switch.
R
R
R
25. On the ENG/APU fire panel 1WD:
- push the ENG 1(2) FIRE
pushbutton switch.
R
R
R
R
R
R
26. On the circuit breaker panels
49VU and 121VU:
R - close the circuit breakers
1QG(2QG) and 3QG(4QG).
On the lower ECAM DU:
-
the ENG 1(2) LP valve is shownin-line and in amber.
On the upper ECAM DU:
-
the ENG 1(2) SHUT DOWN warning message comes into view.
On the lower ECAM DU:
-
the ENG 1(2) LP valve is shownin-line and in green.
On the upper ECAM DU:
-
the ENG 1(2) SHUT DOWN warning message goes out of view.
On the F/O and CAPT glareshield panels 130VU and 131VU:
-
the two MASTER CAUT lights go off.
On the lower ECAM DU:
-there is no change.
R **ON A/C 106-149, 229-299, 303-399, 401-499,
Subtask 26-21-00-720-058-A
A. Functional Test of the ENG 1(2) FIRE Pushbutton Switch
-------------------------------------------------------------------------------ACTION RESULT -------------------------------------------------------------------------------
1. On the ECAM control panel:
-push the BLEED key
2. On the ECAM control panel:
-push the HYD key
3. On the ECAM control panel:
-push the FUEL key
4. On one MCDU:
-get the SYSTEM REPORT/TEST/PNEU page (Ref. TASK 31-32-00-860-011)
5. On the MCDU:
-push the line key adjacent to the CURRENT DATA indication
6. On the MCDU:
-push the line key adjacent to the RETURN indication NOTE : Ignore the indications other
____ than those that follow:
On the lower ECAM DU:
-
the BLEED page comes into view
-
the pack flow control valve 1(2) is shown in-line and in green.
On the lower ECAM DU:
-
the BLEED page goes out of view and the HYD page comes into view
-
the ENG 1(2) G(Y) fire valve is shown in-line and in green.