R 4. Procedure
_________ 
R Subtask 26-22-00-710-072 
R A. Operational Test of the Test Circuit
R WARNING : MAKE SURE THAT YOU WILL NOT CAUSE UNWANTED CHANGES TO OTHER
_______ R SYSTEMS BEFORE YOU PUSH THE APU FIRE PUSHBUTTON SWITCH. WHEN R YOU PUSH THE APU FIRE PUSHBUTTON SWITCH, THESE VALVES CLOSE : R - LP FUEL SHUTOFF VALVE (APU) R - FUEL SOLENOID VALVE (APU) R - BLEED AIR VALVE (APU) 
R 
R -------------------------------------------------------------------------------R ACTION RESULT R -------------------------------------------------------------------------------
R 1. In the APU section of the ENG/APU 
R panel 25 VU: 
R - push and hold the TEST 
R pushbutton switch.
R 
R 
R
R 2. In the APU section of the ENG/APU 
R panel 25 VU: 
R - release the TEST pushbutton 
R switch.
R 5. Close-up
________ 
R Subtask 26-22-00-410-064 In the APU section of the ENG/APU panel 25 VU: 
-the SQUIB legend in the AGENT SQUIB pushbutton switch comes on. 
NOTE : If the SQUIB legend comes on,
____ SQUIB A and SQUIB B operate correctly. 
In the APU section of the ENG/APU panel 25 VU: 
-the SQUIB legend in the AGENT SQUIB pushbutton switch goes off. 
R A. Put the aircraft back to its initial configuration. 
R (1) Remove the warning notice from the panel 25 VU. 
R Subtask 26-22-00-860-065 
R B. Put the aircraft back to its initial configuration. 
R (1) De-energize the aircraft electrical circuits
R (Ref. TASK 24-41-00-862-002).
R  TASK 26-22-00-040-009  
R  To make sure that the APU Automatic Fire Extinguishing System is operative when  
R  the APU AUTO EXTING TEST is inoperative  
R  1. Reason for the Job__________________  
R  Refer to the MMEL TASK: 26-22-10  
R  APU Fire Extinguishing  
R  APU Auto Exting Test  
R  2. Job Set-up Information______________________  
R  A. Fixtures, Tools, Test and Support Equipment  
R  ------------------------------------------------------------------------------- 
R  REFERENCE QTY DESIGNATION  
R  ------------------------------------------------------------------------------- 
R  No specific warning notice  
R  B. Referenced Information  
R  ------------------------------------------------------------------------------- 
R  REFERENCE DESIGNATION  
R  ------------------------------------------------------------------------------- 
R  24-41-00-862-002 De-energize the Aircraft Electrical Circuits Supplied  
R  from the External Power  
R  3. Job Set-up__________  
R  Subtask 26-22-00-941-062  
R  A. Put the warning notice in position on the overhead panel 25VU to tell  
R  persons not to operate the APU.
R 4. Procedure_________ 
R Subtask 26-22-00-710-073 
R A. Operational Test of the Test Circuit
R -------------------------------------------------------------------------------
R ACTION RESULT 
R -------------------------------------------------------------------------------
R 1. In the APU section of the 
R overhead panel 25 VU: 
R - put the APU MASTER switch in 
R the ON position. 
R In the APU/AUTO EXTING section 
R of panel 50 VU: 
R - push the TEST ON pushbutton 
R during the test.
R NOTE : If the APU operates, it
____ R stops. R 
R 2. In the APU/AUTO EXTING section of R panel 50 VU: R - push the RESET pushbutton R switch 
R 5. Close-up
________ 
R Subtask 26-22-00-860-067 In the APU/AUTO EXTING section of panel 50 VU: 
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM FIRE PROTECTION 防火2(57)