(2)
Disconnect the electrical connector (11) from the selector valve manifold-assembly (10).
(3)
Put blanking caps on the disconnected electrical connectors.
(4)
Disconnect the tube assemblies (3), (5) and (9) from the selector valve manifold-assembly (10).
(5)
Put blanking plugs on the disconnected line ends.
(6)
Put blanking caps on the hydraulic connectors (4), (6) and (8) of the selector valve manifold-assembly (10).
(7)
Remove the nut (12), the bolt (16), the washer (15) and the bonding lead (14) from the structure (13).
1EFF : 401-499, 1 32-51-23Page 403 1 1 Aug 01/05 1 1 1CES 1
Selector Valve Manifold-Assembly
Figure 401/TASK 32-51-23-991-001
1EFF : 401-499, 1 32-51-23 Page 404
1 1 Aug 01/05
1 1
1CES 1
(8)
Hold the selector valve manifold-assembly (10) with your hand.
(9)
Remove the bolts (1) and the washers (2).
(10) Remove the selector valve manifold-assembly (10) from the structure (7).
1EFF : 401-499, 1 32-51-23Page 405 1 1 Aug 01/05 1 1 1CES 1 TASK 32-51-23-400-001
Installation of the Selector Valve Manifold-Assembly
WARNING : MAKE SURE THAT THERE IS A GOOD FLOW OF AIR THROUGH THE WORK AREA WHEN
_______ YOU USE SPECIAL MATERIALS. IF YOU GET ONE OF THESE MATERIALS ON YOUR SKIN, IN YOUR MOUTH OR IN YOUR EYES : -FLUSH IT AWAY WITH A FLOW OF CLEAN WATER FOR BETWEEN 10 AND 15 MINUTES. -GET IMMEDIATE MEDICAL AID IF IRRITATION OCCURS. DO NOT BREATHE THE FUMES FROM THE MATERIAL. DO NOT SMOKE WHEN YOU USE THE MATERIAL. DO NOT USE THE MATERIAL NEAR A FLAME, SPARKS OR SOURCES OF HEAT. THESE MATERIALS ARE DANGEROUS : THEY ARE POISONOUS, FLAMMABLE AND SKIN IRRITANTS.
WARNING : OBEY THE MANUFACTURER'S INSTRUCTIONS WHEN YOU USE THIS/THESE
_______ MATERIAL/S. USE PROTECTIVE CLOTHING, RUBBER GLOVES AND A MASK.
WARNING : MAKE SURE THAT ALL THE CIRCUITS IN MAINTENANCE ARE ISOLATED BEFORE
_______ YOU SUPPLY ELECTRICAL POWER TO THE AIRCRAFT.
WARNING : PUT THE SAFETY DEVICES AND THE WARNING NOTICES IN POSITION BEFORE YOU
_______ START A TASK ON OR NEAR:
-
THE FLIGHT CONTROLS
-
THE FLIGHT CONTROL SURFACES
-
THE LANDING GEAR AND THE RELATED DOORS
-COMPONENTS THAT MOVE.
WARNING : OBEY THE HYDRAULIC SAFETY PROCEDURES.
_______
1. Reason for the Job
__________________
Self Explanatory
1EFF : 401-499, 1 32-51-23Page 406 1 1 Aug 01/05 1 1 1CES 1
2. Job Set-up Information
______________________
A. Fixtures, Tools, Test and Support Equipment
-------------------------------------------------------------------------------REFERENCE QTY DESIGNATION -------------------------------------------------------------------------------
No specific 1 ACCESS PLATFORM 2M (6 FT) No specific 1 CONTAINER 5 L(1 1/2 USGAL) No specific 2 WARNING NOTICE
B. Consumable Materials
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
Material No. 02-003 F NSA 307110 TYPE 4 HYDRAULIC FLUID (PHOSPHATE ESTER BASE) (Ref. 20-31-00)
Material No. 05-002 USA MIL-P-8116 PUTTY, ZINC CHROMATE GENERAL PURPOSE (Ref. 20-31-00) Material No. 07-018 USA BMS 10-72 TYPE V VARNISH (Ref. 20-31-00)
Material No. 09-013 USA MIL-PRF-81733 TYPE I CLASS A CORROSION INHIBITING BRUSH CONSISTENCY (Ref. 20-31-00)
C. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
12-12-29-611-001 Fill the Hydraulic Fluid Reservoir with a Hand Pump
20-28-00-912-004 Electrical Bonding of Components With Conductive Bolts and Screws and Bonding Straps in the Fuselage and in the Wings (this does not include the tanks)-
29-00-00-910-002 Safety Procedures of the Hydraulic System 29-10-00-864-002 Depressurize the Yellow Hydraulic System 29-14-00-614-001 Depressurization of the Hydraulic Reservoirs 29-23-00-860-001 Disconnection of the Isolation Coupling of the Power
中国航空网 www.aero.cn
航空翻译 www.aviation.cn